Statement of Need.pdf

PDF 70 KB Posted

Attached to
Fiber Optics Protective Equpment Federal contract opportunity
Solicitation number
FA5422-20-Q-7085
Issued by
Department of the Air Force United States Air Forces in Europe - Air Forces Africa

View the file

Other files for this federal contract opportunity

Other files attached to Fiber Optics Protective Equpment, newest first.
File Type Posted
FA5422-20-Q-7085 Fiber Protective Equipment.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10 June 2020

Statement of Need

Fiber Protective/Installation Project

768 EABS/COMM requires the following equipment, or equal, meeting the listed salient characteristics.

1. 3M EPS-300 Heat Shrink Tubing, Black, 1 1/2"x48”

a. Qty 150 Ea

b. Minimum specs

Material: Polyolefin Shrink Ratio: 3:1 Inner Diameter Before Shrinking: 1.5 in Inner Diameter After Shrinking: 0.51 in Lining: Adhesive-Lined Wall Thickness After Shrinking: 0.1 in Overall Length: 48 in Dielectric Strength: 700 V/mil Shrink Temperature: +250 °F Maximum Operating Temperature: +230 °F Tensile Strength: 2100 psi

2. Maxcell Riser 2 Cell - MXRM3302BK10000

a. Qty 15,000 Ft

b. Minimum specs

Diameter 1.25” Cell 2 Length 15000ft

3. Sleeves, Heat Shrink, 40mm - OR-20500043

b. Minimum specs

40Mm 3Mm To 2.8Mm

4. 3M Splice to LC Female OM3 Fiber - ADD-PT122-IMLC-OMC

a. Qty 25 Ea

b. Minimum specs

Application Pigtail Cable Mode Multiple Color Multicolored Compatible OEM Industry Standard Connector Splice to LC (Female) Core/Cladding 50/125µm Fiber Termination PC - Physical Contact Length (ft) 9.8 Length (m) 3 Fiber Type MMF Standard OM3 Strand Count 12 Media Fiber Jacket Type Riser Termination Type Straight

5. 2M LC to LC multimode OM3 fiber connector - LC2-10G-2M-ENC

b. Minimum specs

Cable Type Fiber Optic Cable Characteristic Patch Cable Fiber Optic Mode Multi-mode Core / Cladding Diameter 50/125 µm Cable Length 6.56 ft Connector on First End 2 x LC Male Network Connector on Second End 2 x LC Male Network Data Transfer Rate 10 Gbit/s

6. Electriduct WL-ED-PSC-125-100, 1.25" UL94-V2 100ft

a. Qty 100 Ea

b. Minimum specs

Refined PVC Coating Water-proof Corrosion Resistant UV Resistant Flame Retardant (UL94-V2) RoHS Compliant Operating range: -10°C to +80°C

7. Electriduct WL-ED-PSC-125-50, 1.25" UL94-V2 50ft

a. Qty 50 Ea

b. Minimum specs

Refined PVC Coating Water-proof Corrosion Resistant UV Resistant Flame Retardant (UL94-V2) RoHS Compliant Operating range: -10°C to +80°C

8. Heat gun - 8988-20

a. Qty 2 Ea

b. Minimum specs

CFM 10.6/17.6

Air Temperatures 110 to 1150 Degrees F Voltage 120V AC Amps 12.5 Max. Watts 1500

9. FUJIKURA 70S fiber splicer - S015591

a. Qty 1 Ea

b. Minimum specs.

Applicable Fibers Single-mode, Multimode, DS, CS, NZDS and Erbium-doped fiber Cladding Diameter 80 - 150 µm Coating Diameter 100 to 3,000 µm Fiber Cleave Length 5 to 16 mm Electrode Life 5,000 Arc Discharges

10. Visual Fault Locater Kit - VFL-150

a. Qty 2 Ea

b. Minimum specs

Fiber Connector FC, LC, SC, ST Light Source Class IIIA Laser Diode Distance Up to 5km (3.10 miles) Wavelength 650nm Storage Temperature -40 Fahrenheit (-40 Celsius) to 185 Fahrenheit (85 Celsius) Working Temperature -4°F to 140°F (-20°C to 60°C)

11. Cable Slitter & Ring Tool - JIC-4366

a. Qty 2 Ea

b. Minimum specs

Cut Type Ring, Slit Cable Type Jacket, Loose Tube Cable Diameter 3/16"-1/2" (4.7 mm-12.7 mm) Max Blade Depth 1/8"-3/8" (3.2 mm-9.6 mm)