St Regis Arsenic Removal - Plans - Signed.pdf

PDF 2 MB Posted

Attached to
USDA Forest Service, Lolo National Forest, St. Regis Arsenic Treatment System Project
Solicitation number
1240LU24Q0019
Issued by

About this file

This set of documents includes construction plans and specifications for the St. Regis Arsenic Treatment System Project for the Lolo National Forest. The plans show the layout and details for demolishing an existing pump house and well system, and installing a new arsenic removal system using drywell leach fields. The system will connect to an existing well and treat water to remove arsenic above federal standards before discharging to the leach fields. Key project elements include demolishing the pump house and associated piping, installing a new arsenic filtration system in the pump house, connecting to the well, and constructing four 50-gallon drywells with associated piping in the leach field area. Relevant construction details and specifications are provided.

The related federal contract opportunity is a solicitation for the St. Regis Arsenic Treatment System Project issued by the USDA Forest Service Lolo National Forest. Interested contractors are instructed to carefully review all documents and attachments and submit any responses to the identified contracting officer via email.

View the file

Other files

File Type Posted
1240LU24Q0019.pdf PDF
6133-00215 MT DEQ Spec Drwg Approval Ltr 2023-1205.pdf PDF
Wage Determination.pdf PDF
St Regis Arsenic Removal - Specifications.pdf PDF
Section B-M.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MISSOULA

HAMILTON

ANACONDA

PHILIPSBURG

DRUMMOND

DEER LODGE

HELENA

GREAT FALLS

KALISPELL

LIBBY

EUREKA

POLSON

OROFINO

LEWISTON

ST REGIS

MTID

DATE

FOREST SUPERVISOR

LOLO NATIONAL FOREST

APPROVED:

LOLO DISTRICT RANGER

LOLO NATIONAL FOREST

RECOMMENDED:

FOREST ENGINEER

LOLO NATIONAL FOREST

REVIEWED:

DIRECTOR OF ENGINEERING

NORTHERN REGION

APPROVED:

DATE

DATE

DATE

DRAWING No. ----

REGION ONE

©COPYRIGHT

MORRISON-MAIERLE, INC.

engineers surveyors planners scientists

MorrisonMaierle 1055 Mount Avenue Missoula, MT 59801 Phone: 406.542.8880 Fax: 406.542.4801

VICINITY MAP

SEC.10, T.16 N., R. 16 W.

SOUTHWESTERN MONTANA

SCALE: NO SCALE

SCALE: NO SCALE

T. 12 N.

T. 13 N.

R . 1

W

R . 2

W

U.S. DEPARTMENT OF AGRICULTURE FOREST SERVICE, REGION ONE

PROPOSED PLANS FOR:

ST REGIS WORK CENTER

ARSENIC REMOVAL SYSTEM

LOLO NATIONAL FOREST

LOLO RANGER DISTRICT

MINERAL COUNTY, MONTANA

THIS

PROJECT

THIS

PROJECT

M :\6

R

IV

ER

D

ES

IG

N G

R O

U P\

LN

F

ST

R

EG

IS

W

O R

K C

EN

TE

R A

R

SE

N

IC

R

EM

O

VA

L

SY

ST

EM

\A C

AD

\S

H

EE

TS

\G

EN

ER

AL

\C

O

VE

R .D

W G

P

LO

TT

ED

B Y:

AA

R

O N

M C

C O

N

KE

Y O

N A ug /2

1/

MULLAN GULCH RD

ST

R

EG

IS

S

T

INDEX TO SHEETS

NO. DESCRIPTION

1 COVER

2 SITE PLAN

3 PUMP HOUSE DEMO

4 PUMP HOUSE LAYOUT

5 DETAILS

CALE

MAGES

No. 72160 PE

MONT A NA

P R

O

FESS I ONA L ENG

I N E

E R

L I C E NS ED

T

SS

S W

T

EE

T

W

W

T

W

E

S

W

T

S

OHP

OHP

OHP

O

HP

O

HP

O

HP

O

HP

O

HP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

E0.7 5W

BP

E1W

E1W

E1W

E1.25W

E1W

E1W

E4 W

E4 W

E4 W

E4 W

E4 W

E4 W

E1W

E2 W

S

S

S

S

S

E3W E3W

E3W S

S E

W

S T

W

2W

EXISTING BUILDING

EXISTING CONCRETE

EXISTING GRAVEL ROAD

EXISTING OVERHEAD POWER

EXISTING CONTROL POINT

EXISTING CURB STOP

EXISTING FROST FREE HYDRANT

EXISTING WELL

EXISTING POWER POLE

EXISTING BOLLARD

EXISTING ELECTRIC METER

EXISTING GUY ANCHOR

EXISTING TELEPHONE PEDESTAL

EXISTING MANHOLE - SANITARY SEWER

EXISTING SIGN POST

EXISTING CONIFEROUS TREE

EXISTING WATER SERVICE (SIZE IN INCHES)

EXISTING SEWER SERVICE

PROPOSED PRESSURE SEWER SERVICE

S

S

EXISTING MAILBOXES

EXISTING 2" IRON

PIPE STUB-UP

EXISTING BURIED POWER

GOING IN TO PUMP HOUSE

EXISTING

GARAGE

EXISTING TRASH

ENCLOSURE

LEGEND

Sheet: 2 of 5Drawn By:BTB Designed By:CAM

Drawing Checked:AJM Design Checked:AJM

ST REGIS WORK CENTER ARSENIC REMOVAL

SYSTEM

SITE PLAN

©COPYRIGHT

MORRISON-MAIERLE, INC.

engineers surveyors planners scientists

MorrisonMaierle 1055 Mount Avenue Missoula, MT 59801 Phone: 406.542.8880 Fax: 406.542.4801

M :\6

R

IV

ER

D

ES

IG

N G

R O

U P\

LN

F

ST

R

EG

IS

W

O R

K C

EN

TE

R A

R

SE

N

IC

R

EM

O

VA

L

SY

ST

EM

\A C

AD

\S

H

EE

TS

\C

IV

IL

\2

SI

TE

P

LA

N .D

W G

P

LO

TT

ED

B Y:

AA

R

O N

M C

C O

N

KE

Y O

N A ug /2

1/

GENERAL NOTES

1. CONTRACTOR SHALL BACKFILL ALL EXCAVATED AREAS TO

FINISHED GRADE AND PROVIDE POSITIVE DRAINAGE AWAY FROM

ALL STRUCTURES.

2. THE LOCATION, DEPTH, AND SIZE OF EXISTING UTILITIES SHOWN ON

THESE DRAWINGS IS APPROXIMATE. THE CONTRACTOR SHALL

FIELD VERIFY THE EXISTENCE, LOCATION, DEPTH, SIZE, LINE AND

GRADE OF EXISTING UTILITIES PRIOR TO CONSTRUCTION. THE

CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE

TO THE EXISTING FACILITIES DUE TO FAILURE TO LOCATE OR

PROVIDE PROPER PROTECTION WHEN LOCATION IS KNOWN.

KEY NOTES

2-INCH SDR 26 ASTM D2241 PVC PRESSURE SEWER

LINE. MAINTAIN MIN. 6-FT BURY DEPTH. ANY

PRESSURE PIPE WITH LESS THAN 6-FT BURY

SHALL BE COVERED BY RIGID BLUE BOARD

INSULATION. OTHERWISE INSTALL PIPE PER

MANUFACTURER SPECIFICATION AND DETAIL ON

SHEET 5.

PROPOSED 200 GAL MIN. DRYWELL SYSTEM, NDS

FLO-WELL OR APPROVED EQUAL.

SCALE IN FEET

30150

HORIZONTAL SCALE

DRYWELL DETAIL

NOT TO SCALE

EXISTING DRINKING

WATER WELL

EXISTING 100' WELLHEAD

PROTECTION ZONE

BOLLARD, TYP3

50-GAL. NDS FLO

WELL OR APPROVED

EQUAL, TYP. OF 4

2" PRESSURE BACKWASH LINE

FROM WELL BUILDING SUMP

4" X 2" REDUCER

4" SDR 35 D-3034 PVC

INSTALLED FLAT, TYP OF 4

FILL SPACE AROUND

DRYWELLS WITH 3/4-0

WASHED DRAIN ROCK

PLACE NON-WOVEN

FILTER FABRIC AROUND

SUMPS AND BETWEEN

DRAIN ROCK AND

TRENCH BOTTOM AND

ALL SIDES.

3' MIN. SEPARATION

BETWEEN DRYWELLS

2' MIN. SEPARATION BETWEEN

DRYWELL AND EDGE OF TRENCH

SITE PLAN

SCALE: 1"=30'

CONTROL POINT TABLE

POINT #

RAW DESCRIPTION

RPC

NAIL

NAIL

NORTHING

20000.00

20001.08

20238.37

EASTING

40000.00

39857.46

39735.12

ELEVATION

2660.28

2660.96

2665.19

EXISTING NON-POTABLE

WATER YARD HYDRANT

CALE

MAGES

No. 72160 PE

MONT A NA

P R

O

FESS I ONA L ENG

I N E

E

Sheet: 3 of 5Drawn By:BTB Designed By:CAM

Drawing Checked:AJM Design Checked:AJM

ST REGIS WORK CENTER ARSENIC REMOVAL

SYSTEM

PUMP HOUSE DEMO

©COPYRIGHT

MORRISON-MAIERLE, INC.

engineers surveyors planners scientists

MorrisonMaierle 1055 Mount Avenue Missoula, MT 59801 Phone: 406.542.8880 Fax: 406.542.4801

M :\6

R

IV

ER

D

ES

IG

N G

R O

U P\

LN

F

ST

R

EG

IS

W

O R

K C

EN

TE

R A

R

SE

N

IC

R

EM

O

VA

L

SY

ST

EM

\A C

AD

\S

H

EE

TS

\C

IV

IL

\3

PU

M

P H

O U

SE

L

AY

O

U T.

D W

G P

LO

TT

ED

B

Y:

AA

R O

N M

C C

O N

KE

Y

O N

A ug

/2 1/

EX FLEXCON

PC266R PRESSURE

TANK

EX FLEXCON

PC266R PRESSURE

TANK

EX FLEXCON

PC266R PRESSURE

TANK

EX FLEXCON

PC266R PRESSURE

TANK

TO EXISTING WATER MAIN TO EXISTING NON POTABLE YARD HYDRANT

REMOVE AND SALVAGE

EQUIPMENT FOR REUSE

REMOVE AND SALVAGE

EQUIPMENT FOR REUSE

REMOVE AND DISPOSE

OF PIPE AND FITTINGS

REMOVE AND DISPOSE

OF PIPE AND FITTINGS

REMOVE AND DISPOSE

OF PIPE AND FITTINGS

FROM WELL

EXISTING PUMP HOUSE LAYOUT & DEMOLITION PLAN

NOT TO SCALE

EXISTING CMU BLOCK TANK PAD

9'

16'

EXISTING PRE-CAST

CONCRETE BUILDING

EXISTING ELECTRICAL PANEL

EXISTING WELL

CONTROL CENTER

CALE

MAGES

No. 72160 PE

MONT A NA

P R

O

FESS I ONA L ENG

I N E

E

Sheet: 4 of 5Drawn By:BTB

Drawing Checked:AJM Design Checked:AJM

ST REGIS WORK CENTER ARSENIC REMOVAL

SYSTEM

PUMP HOUSE LAYOUT

©COPYRIGHT

MORRISON-MAIERLE, INC.

engineers surveyors planners scientists

MorrisonMaierle 1055 Mount Avenue Missoula, MT 59801 Phone: 406.542.8880 Fax: 406.542.4801

M :\6

R

IV

ER

D

ES

IG

N G

R O

U P\

LN

F

ST

R

EG

IS

W

O R

K C

EN

TE

R A

R

SE

N

IC

R

EM

O

VA

L

SY

ST

EM

\A C

AD

\S

H

EE

TS

\C

IV

IL

\3

PU

M

P H

O U

SE

L

AY

O

U T.

D W

G P

LO

TT

ED

B

Y:

AA

R O

N M

C C

O N

KE

Y

O N

A ug

/2 1/

EX FLEXCON

PC266R PRESSURE

TANK

EX FLEXCON

PC266R PRESSURE

TANK

EX FLEXCON

PC266R PRESSURE

TANK

EX FLEXCON

PC266R PRESSURE

TANK

TO EXISTING WATER MAIN

TO EXISTING NON-POTABLE YARD HYDRANT

FROM WELL

PUMP HOUSE PLAN

NOT TO SCALE

PROPOSED 2-INCH SCH 40

PVC TO DRYWELL

GENERAL NOTES

1. ALL PROPOSED PUMP HOUSE PIPING SHALL

BE GALVANIZED IRON PIPE UNLESS NOTED

OTHERWISE.

CONNECT PROPOSED

AND EXISTING 2" PIPING

CONNECT PROPOSED AND

EXISTING 1-1/2" PIPING

EXISTING EQUIPMENT

RELOCATED

EXISTING EQUIPMENT

RELOCATED

1-1/2" RPZ BACKFLOW

PREVENTER

1-1/2" BALL

VALVE

CONNECT PROPOSED

AND EXISTING 2" PIPING

CONNECT PROPOSED

PIPING TO EXISTING

2" CHECK VALVE

1-1/2" BALL VALVE, TYP OF 4

1-1/2" UNION, TYP OF 4

2" BALL VALVE

PLUG EXISTING 1-1/2" TEE

CULLIGAN HE 1.5

ARSENIC FILTER

1-1/2" BALL

VALVE

2" CHECK VALVE

AND UNION

PROPOSED SUMP PUMP RATED

FOR 30 GPM @ 10 FT OF HEAD

FIELD ROUTE POWER

AND CONTROL WIRING

TO ARSENIC FILTER

EXISTING WELL

CONTROL CENTER

EXISTING ELECTRICAL

PANEL

TERMINATE BACKWASH

PIPING ABOVE SUMP LID TO

MAINTAIN AN AIR GAP

CALE

MAGES

No. 72160 PE

MONT A NA

P R

O

FESS I ONA L ENG

I N E

E

Sheet: 5 of 5Drawn By:BTB

Drawing Checked:AJM Design Checked:AJM

ST REGIS WORK CENTER ARSENIC REMOVAL

SYSTEM

DETAILS

©COPYRIGHT

MORRISON-MAIERLE, INC.

engineers surveyors planners scientists

MorrisonMaierle 1055 Mount Avenue Missoula, MT 59801 Phone: 406.542.8880 Fax: 406.542.4801

M :\6

R

IV

ER

D

ES

IG

N G

R O

U P\

LN

F

ST

R

EG

IS

W

O R

K C

EN

TE

R A

R

SE

N

IC

R

EM

O

VA

L

SY

ST

EM

\A C

AD

\S

H

EE

TS

\C

IV

IL

\5 D

ET

AI

LS

.D

W G

P

LO

TT

ED

B Y:

AA

R

O N

M C

C O

N

KE

Y O

N A ug /2

1/

UTILITY TRENCH DETAIL

NOT TO SCALE

BOLLARD DETAIL

NOT TO SCALE

4"

6"

SLOPING, BENCHING OR SHORING

SYSTEMS AS REQUIRED TO COMPLY

WITH O.S.H.A REGULATIONS

DETECTABLE WARNING

TAPE AT 18" DEPTH

TRACER

WIRE

PIPE BEDDING

PLACED IN 6" MAX.

LAYERS AND COMPACTED

AS SPECIFIED.

PIPE BEDDING

WHERE REQUIRED

FOR

SOFT OR UNSTABLE

FOUNDATION.

RESTORE ROAD SURFACE TO

MATCH EXIST. WITH MIN. 6"

THICK CRUSHED BASE COURSE

AND 6" SELECT SUBGRADE FILL12"

12"EXISTING

GRADE

8"

TYPE "A" TRENCH BACKFILL

UNLESS OTHERWISE

SPECIFIED

MAX. TRENCH WIDTH

PIPE DIA. + 36"

MIN. TRENCH WIDTH

PIPE DIA. +24"

D

EP

TH

V

AR

IE

S

SE

E

PR

O

FI

LE

UNIMPROVED AREA

SURFACE RESTORATION

ROADWAY

SURFACE RESTORATION

MOUND TOP SOIL OVER

TRENCH

SUBGRADE

18"

24"

PUMP CONTROL CABLE WHERE

REQUIRED

WARNING TAPE AT 12" DEPTH

PROVIDE PIPE BEDDING 4" DEPTH

BELOW AND ABOVE CABLE

MIN. TRENCH

WIDTH IS 12"

DRYWELL SECTION

NOT TO SCALE

PRESSURE BACKWASH AND

DRAIN LINE FROM PUMP HOUSE

SLOPE @1% MIN.

EXISTING GROUND

SURFACEREDUCER

NATIVE EARTH

ROCK BEDDING

AND BACKFILL

FILTER FABRIC WRAP

OF ENTIRE TRENCH

AND DRAIN ROCK

LANDSCAPE FILTER

WRAP ON INDIVIDUAL

FLO-WELLS

FLAT PIPE, NO SLOPE

FINISHED GRADE

CROWN TOP OF CONCRETE

PAINT OSHA YELLOW OR

YELLOW PLASTIC SLEEVE

4" STEEL PIPE FILLED

WITH CONCRETE.

6"

4'-0"

2'-6"

6"

1'-6"

1"

2" WIDE REFLECTIVE TAPE3"

STRUCTURAL

CONCRETE

CALE

MAGES

No. 72160 PE

MONT A NA

P R

O

FESS I ONA L ENG

I N E

E

1 COVER
2 SITE PLAN
3 PUMP HOUSE DEMO
4 PUMP HOUSE LAYOUT
5 DETAILS
2023-12-11T18:04:28-0700
ABIGAIL LANE
2023-12-12T08:15:36-0700
CATINA MCLEAN
2023-12-12T15:00:50-0700
JEREMY CASTERSON
2023-12-15T08:00:36-0700
DANIEL HAGER

File details come from the government source that posted it. Updated .