ST LOUIS CORRECTIONAL FACILITY CDs 1-2-19 1 of 2.pdf
PDF 5 MB Posted
- Solicitation number
- RFQ-171-190000000151-3
- Issued by
- Gogebic County, Michigan
About this file
This document is a construction design set for shower renovations at the St. Louis Correctional Facility located at 8585 N. Croswell Rd. in St. Louis, Michigan, prepared by DS Architects for the Department of Technology, Management & Budget, State Facilities Administration. The project involves comprehensive shower renovations across seven buildings, with each building containing 8 showers (4 on each level), totaling 56 showers. Barrier-free showers are specifically located on the first level of Buildings 1 and 7. The renovation includes replacing surface-mounted gypsum board ceiling light fixtures, installing new Kenall light fixtures, and potential alternate improvements such as stainless steel wall-mounted liner coverings and electronic shower valve systems.
The project is governed by multiple Michigan building codes, including the Michigan Rehabilitation Code, Michigan Plumbing Code, and Michigan Electrical Code. The facility is classified as a Type 2B construction with an I3 use group and is fully sprinkled. The design documents include provisions for touch sensors, electronic in-line shower valves, and AC controllers from 'I-CON' systems. The project was issued for bid on 1-2-19 by Joel Gordon, the Project Director, with contact information provided at the Department of Technology, Management & Budget in Lansing. The design emphasizes maintaining existing infrastructure while implementing modern, code-compliant renovations for the correctional facility's shower facilities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Photo 338.PDF | ||
| St Louis shower specs 1-2-19.pdf | ||
| DTMB-0415 472 17471JAG.pdf | ||
| LEIN Request REV 04-2018 17471.pdf | ||
| Photo 342.PDF | ||
| Sign in sheets.PDF | ||
| Photo 336 and 337.PDF | ||
| Photo 341 and 342.PDF | ||
| ST LOUIS CORRECTIONAL FACILITY CDs 1-2-19 2 of 2.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet Number of
Dwg.
Scale
Issued for
Checked
Date By
Project Number
Drawn
Drawing Title
P ro je c t
CLARKSTON, MI
7300 DIXIE HWY.
Seal
PHONE
FAX
PHONE
248.605.2030 248.605.2030
48346 #600
WEB DSARCHITECTS.COM
ST
. LO
UI
S C
OR
RE
CT
IO
NA
L
FA
CI
LIT
Y -
HO
US
IN
G U
NI
T
N C
R O
S W
E L L R
D
S T
L O
U
IS
M
I
LEGEND SHEET
18-40-129
BKO
DJS
OWNER REVIEW 11-29-18 DJS
BID 1-2-19 DJS
N/A
ST. LOUIS CDs
A-1
SH
OW
ER
RE
NO
VA
TIO
NS
AutoCAD SHX Text
GENERAL LIGHT FIXTURE LEGEND
AutoCAD SHX Text
GENERAL CONSTRUCTION LEGEND
AutoCAD SHX Text
EXISTING CONSTRUCTION TO REMAIN.
AutoCAD SHX Text
CONTACT INFORMATION
AutoCAD SHX Text
RENOVATIONS FOR:
AutoCAD SHX Text
ST. LOUIS
AutoCAD SHX Text
CORRECTIONAL
AutoCAD SHX Text
FACILITY - HOUSING
AutoCAD SHX Text
ST. LOUIS, MICHIGAN
AutoCAD SHX Text
8585 N. CROSWELL RD.
AutoCAD SHX Text
BUILDING CODE: MICHIGAN REHABILITATION CODE
AutoCAD SHX Text
BUILDING CONSTRUCTION TYPE: 2B
AutoCAD SHX Text
FIRE SUPPRESSION: FULLY SPRINKLED
AutoCAD SHX Text
BUILDING USE GROUP: I3
AutoCAD SHX Text
CODE INFORMATION
AutoCAD SHX Text
ALL DIMENSIONAL LUMBER, PLYWOOD, PARTICLE BD., FURRING AND BLOCKING SHALL BE
AutoCAD SHX Text
CUTTING HAS EXPOSED ANY UNFINISHED SURFACES. REPAIR ANY DAMAGE TO EXISTING
AutoCAD SHX Text
FINISH TO ORIGINAL CONDITION. EXTEND/REFINISH ALL FRAMES, BASE AND TRIM WHERE
AutoCAD SHX Text
DAMAGE. WHERE EXISTING WORK IS TO BE REMOVED OR ALTERED, RESTORE ADJACENT
AutoCAD SHX Text
SHALL BE PROTECTED BY ALL SUITABLE MEANS NECESSARY TO PREVENT OR MINIMIZE
AutoCAD SHX Text
CONTRACT" (N.I.C.). EXISTING WORK ADJACENT TO, OR IN THE AREA OF NEW WORK
AutoCAD SHX Text
FOR THE WORK DESCRIBED IN THESE DOCUMENTS UNLESS CLEARLY NOTED "NOT IN
AutoCAD SHX Text
CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS AND EQUIPMENT
AutoCAD SHX Text
TO DS ARCHITECTS, INC. PRIOR TO BEGINNING ANY WORK OR FABRICATION.
AutoCAD SHX Text
RESPECT TO THE WORK DESCRIBED IN THESE DOCUMENTS. REPORT ANY INCONSISTENCIES
AutoCAD SHX Text
CONTRACTOR(S) SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND DIMENSIONS WITH
AutoCAD SHX Text
ALL INTERIOR ROOM FINISHES TO MEET CLASS C FLAME SPREAD, 76-200 MAX.
AutoCAD SHX Text
CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES
AutoCAD SHX Text FREE OF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR
AutoCAD SHX Text
AND SHALL BE STORED IN A LOCATION APPROVED BY THE LANDLORD. NO PERSONAL RADIOS
AutoCAD SHX Text
SHALL BE ALLOWED IN OCCUPIED BUILDINGS.
AutoCAD SHX Text
WORK AND RESTORE TO ORIGINAL CONDITION.
AutoCAD SHX Text
PRESSURE TREATED/U.L. CERTIFIED NON-COMBUSTIBLE.
AutoCAD SHX Text %%uGENERAL NOTES & SPECIFICATIONS
AutoCAD SHX Text
ITEMS. IF THE OWNER DOES NOT EXERCISE THAT RIGHT THEN DISPOSE OF ALL DISCARDED
AutoCAD SHX Text
THE BUILDING OWNER SHALL HAVE THE "RIGHT OF FIRST REFUSAL" OF ANY SALVAGED
AutoCAD SHX Text
ITEMS IN A LEGAL, OFF SITE, MANNER.
AutoCAD SHX Text
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. ALL DIMENSIONS ON FLOOR
AutoCAD SHX Text
PLAN ARE TO FACE OF GYPSUM BOARD UNLESS NOTED OTHERWISE.
AutoCAD SHX Text
%%UCONSTRUCTION:
AutoCAD SHX Text
COMMERCIAL CODES CURRENTLY
AutoCAD SHX Text ICC/ANSI A117.1. 2009 & MICHIGAN BARRIER FREE DESIGN LAW OF PUBLIC ACT 1 OF 1966 AS AMENDED
AutoCAD SHX Text
IN EFFECT
AutoCAD SHX Text
COMMERCIAL: MPC 2015 (MICHIGAN PLUMBING CODE 2015)
AutoCAD SHX Text
MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS 2015
AutoCAD SHX Text MICHIGAN ENERGY CODE, PART 10a. RULES (ANSI/ASHRAE/IES STANDARD 90.1-2013)
AutoCAD SHX Text REMOVE AND DISPOSE OF EXISTING SURFACE MOUNTED GYPSUM BOARD CEILING LIGHT FIXTURE. INSTALL NEW LIGHT FIXTURE IN SAME LOCATION. NEW GYPSUM BOARD CEILING SURFACE MOUNTED LIGHT FIXTURE BY 'KENALL' (KENALL.COM) MIGHTY MAC SSA SERIES #SSA4/145L35KDVJ/1WL.
AutoCAD SHX Text
MICHIGAN ELECTRICAL CODE BASED ON 2014 N.E.C. WITH PART 8 STATE AMENDMENTS
AutoCAD SHX Text
FOR EXISTING BUILDINGS 2015
AutoCAD SHX Text
UNIT SHOWER
AutoCAD SHX Text
RENOVATIONS
AutoCAD SHX Text
FILE NO. 472/17471.JAG
AutoCAD SHX Text
INDEX NO. 60230
AutoCAD SHX Text
%%UU.S. & EXPRESS MAIL ADDRESS
AutoCAD SHX Text
DEPARTMENT OF TECHNOLOGY, MANAGEMENT & BUDGET
AutoCAD SHX Text
STATE FACILITIES ADMINISTRATION
AutoCAD SHX Text
DESIGN AND CONSTRUCTION DIVISION
AutoCAD SHX Text
3111 WEST ST. JOSEPH STREET
AutoCAD SHX Text
LANSING, MI 48917
AutoCAD SHX Text
JOEL GORDON, PROJECT DIRECTOR
AutoCAD SHX Text
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
AutoCAD SHX Text
STATE FACILITIES ADMINISTRATION, DESIGN AND CONSTRUCTION DIVISION
AutoCAD SHX Text
P.O. BOX 30026
AutoCAD SHX Text
LANSING, MI 48909
AutoCAD SHX Text
TELEPHONE NUMBER: (517) 242-0761
AutoCAD SHX Text
EMAIL: GORDONJ1@MICHIGAN.GOV
AutoCAD SHX Text
ALTERNATES
AutoCAD SHX Text ALTERNATE NO. 1: INDICATED DASHED LINE REPRESENTS TO PROVIDE AND INSTALL 14 GAUGE STAINLESS STEEL WALL MOUNTED FLOOR TO CEILING LINER COVERING OVER INDICATED EXISTING TO REMAIN PORCELAIN TILED WALL PARTITIONS AS REQUIRED FROM FLOOR TO CEILING. LINER COVERING TO BE INSTALLED USING STAINLESS STEEL DRIVE PINS. PROVIDE STAINLESS STEEL DRIVE PINS ALONG VERTICAL EDGES EVERY 12" O.C. FROM FLOOR UPWARDS AND 6" O.C. FROM VERTICAL OUTER EDGES OF LINER COVERING HORIZONTALLY AT TOPS AND BOTTOMS AND THEN ALSO IN THE CENTER OF LINER COVERING (SEE ELEVATIONS). TORX DRIVE SCREWS ARE FORBIDDEN.
AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: BARRIER FREE SHOWERS TO HAVE TOUCH SENSOR (TS) LOCATED ON SAME WALL AS SHOWER HEAD.
AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: REWORK OR ABANDON EXISTING SHOWER VALVE AS REQUIRED FOR INSTALLATION OF NEW ELECTRONIC SHOWER VALVE (SV).
AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: EXACT PLUMBING SIZE AND CONFIGURATION NEEDED TO CONNECT THE NEW ELECTRONIC IN LINE SHOWER VALVE (SV) TO THE EXISTING SHOWER HEAD IS TO BE DETERMINED IN THE FIELD.
AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: EXACT PATH FOR LOW VOLTAGE WIRE FROM TOUCH SENSOR (TS) TO CONTROLLER TO BE DETERMINED IN FIELD BY INSTALLER.
AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: REMOVE AND REPLACE EXISTING SHOWER VALVES AS REQUIRED FOR ALL SHOWER CLUSTERS WITH THE FOLLOWING:
AutoCAD SHX Text NEW AC CONTROLLERS (AC) USING EITHER 'I-CON' NEXUS MODEL - 4 I/O AC CONTROLLER #CTR-X12-AC-04 SERIES OR NEXUS MODEL - 8 I/O AC CONTROLLER #CTR-X12-AC-08 SERIES BASED ON SHOWER VALVE QUANTITY
AutoCAD SHX Text 'I-CON' TRUTOUCH MODEL FORCE ACTIVATED TOUCH SENSOR (TS) #SEN-1501 (LEAD CABLE LENGTH TO BE DETERMINED BY INSTALLER)
AutoCAD SHX Text
'I-CON' ELECTRONIC IN-LINE SHOWER VALVE (SV) #VLV-SHW-5775-0808-S-0914-002
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text A-1
AutoCAD SHX Text
LEGEND SHEET
AutoCAD SHX Text
ELEVATIONS
AutoCAD SHX Text
FLOOR / CEILING PLANS
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text A-4
AutoCAD SHX Text A-2
AutoCAD SHX Text A-3
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text A-5
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
OF SITE
AutoCAD SHX Text
N. CROSWELL RD.
AutoCAD SHX Text
E. MONROE RD. / 46
AutoCAD SHX Text
ST. LOUIS, MI 48880
AutoCAD SHX Text
8585 N. CROSWELL RD.
AutoCAD SHX Text
%%USUITE LOCATION PLAN
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
LOCATION PLAN
AutoCAD SHX Text
HUBBARD ST.
AutoCAD SHX Text
N. UNION RD.
AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: REMOVE PORTION OF MASONRY WALL AS REQUIRED FOR INSTALLATION OF AND FUTURE SERVICING OF TOUCH SENSOR.
AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: PROVIDE 14 GAUGE TYPE 304 STAINLESS STEEL PLATE WITH BRUSHED FINISH TO COVER MASONRY ACCESS HOLE OPENING (SIZE TO BE DETERMINED) FOR TOUCH SENSOR (TS) WITH FOUR (4) SCREWS TYPICAL IN JAN. ROOM. NO STEEL PLATE REQUIRED FOR TOUCH SENSOR BACKING UP TO PLUMBING CHASE.
Sheet Number of
Dwg.
Scale
Issued for
Checked
Date By
Project Number
Drawn
Drawing Title
P ro je c t
CLARKSTON, MI
7300 DIXIE HWY.
Seal
PHONE
FAX
PHONE
248.605.2030 248.605.2030
48346 #600
WEB DSARCHITECTS.COM
ST
. LO
UI
S C
OR
RE
CT
IO
NA
L
FA
CI
LIT
Y -
HO
US
IN
G U
NI
T
N C
R O
S W
E L L R
D
S T
L O
U
IS
M
I
SITE PLAN
18-40-129
BKO
DJS
OWNER REVIEW 11-29-18 DJS
BID 1-2-19 DJS
NO SCALE
ST. LOUIS CDs
A-2
BUILDING 5
RE
NO
VA
TIO
NS
SH
OW
ER
BUILDING 1
BUILDING 2
BUILDING 3
BUILDING 4
BUILDING 6
BUILDING 7
BUILDING ENTRY
VISITORS
PARKING
LOT
AutoCAD SHX Text
%%USITE NOTES
AutoCAD SHX Text
AutoCAD SHX Text
%%USITE PLAN
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text BUILDINGS 1 - 7 EACH CONTAIN 8 SHOWERS, WITH 4 ON THE FIRST LEVEL AND 4 ON THE SECOND LEVEL, WITH 2 ON THE LEFT AND 2 ON THE RIGHT OF EACH LEVEL. THE BARRIER FREE SHOWERS ARE LOCATED ON THE FIRST LEVEL OF BUILDINGS 1 AND 7 AND ON THE RIGHT. THERE ARE 56 SHOWERS IN TOTAL.
AutoCAD SHX Text
| Sheets and Views |
| ST.LOUIS CORRECTIONAL FACILITY CDs-LEGEND |
| ST.LOUIS CORRECTIONAL FACILITY CDs-SITE PLAN |
| ST.LOUIS CORRECTIONAL FACILITY CDs-FLR CEIL |
| ST.LOUIS CORRECTIONAL FACILITY CDs-ELEV'S |
| ST.LOUIS CORRECTIONAL FACILITY CDs-DETAIL |
File details come from the government source that posted it. Updated .