This document is a construction design set for shower renovations at the St. Louis Correctional Facility located at 8585 N. Croswell Rd. in St. Louis, Michigan, prepared by DS Architects for the Department of Technology, Management & Budget, State Facilities Administration. The project involves comprehensive shower renovations across seven buildings, with each building containing 8 showers (4 on each level), totaling 56 showers. Barrier-free showers are specifically located on the first level of Buildings 1 and 7. The renovation includes replacing surface-mounted gypsum board ceiling light fixtures, installing new Kenall light fixtures, and potential alternate improvements such as stainless steel wall-mounted liner coverings and electronic shower valve systems.

The project is governed by multiple Michigan building codes, including the Michigan Rehabilitation Code, Michigan Plumbing Code, and Michigan Electrical Code. The facility is classified as a Type 2B construction with an I3 use group and is fully sprinkled. The design documents include provisions for touch sensors, electronic in-line shower valves, and AC controllers from 'I-CON' systems. The project was issued for bid on 1-2-19 by Joel Gordon, the Project Director, with contact information provided at the Department of Technology, Management & Budget in Lansing. The design emphasizes maintaining existing infrastructure while implementing modern, code-compliant renovations for the correctional facility's shower facilities.

View the file

Other files

File Type Posted
Photo 338.PDF PDF
St Louis shower specs 1-2-19.pdf PDF
DTMB-0415 472 17471JAG.pdf PDF
LEIN Request REV 04-2018 17471.pdf PDF
Photo 342.PDF PDF
Sign in sheets.PDF PDF
Photo 336 and 337.PDF PDF
Photo 341 and 342.PDF PDF
ST LOUIS CORRECTIONAL FACILITY CDs 1-2-19 2 of 2.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet Number of

Dwg.

Scale

Issued for

Checked

Date By

Project Number

Drawn

Drawing Title

P ro je c t

CLARKSTON, MI

7300 DIXIE HWY.

Seal

PHONE

FAX

PHONE

248.605.2030 248.605.2030

48346 #600

WEB DSARCHITECTS.COM

ST

. LO

UI

S C

OR

RE

CT

IO

NA

L

FA

CI

LIT

Y -

HO

US

IN

G U

NI

T

N C

R O

S W

E L L R

D

S T

L O

U

IS

M

I

LEGEND SHEET

18-40-129

BKO

DJS

OWNER REVIEW 11-29-18 DJS

BID 1-2-19 DJS

N/A

ST. LOUIS CDs

A-1

SH

OW

ER

RE

NO

VA

TIO

NS

AutoCAD SHX Text

GENERAL LIGHT FIXTURE LEGEND

AutoCAD SHX Text

GENERAL CONSTRUCTION LEGEND

AutoCAD SHX Text

EXISTING CONSTRUCTION TO REMAIN.

AutoCAD SHX Text

CONTACT INFORMATION

AutoCAD SHX Text

RENOVATIONS FOR:

AutoCAD SHX Text

ST. LOUIS

AutoCAD SHX Text

CORRECTIONAL

AutoCAD SHX Text

FACILITY - HOUSING

AutoCAD SHX Text

ST. LOUIS, MICHIGAN

AutoCAD SHX Text

8585 N. CROSWELL RD.

AutoCAD SHX Text

BUILDING CODE: MICHIGAN REHABILITATION CODE

AutoCAD SHX Text

BUILDING CONSTRUCTION TYPE: 2B

AutoCAD SHX Text

FIRE SUPPRESSION: FULLY SPRINKLED

AutoCAD SHX Text

BUILDING USE GROUP: I3

AutoCAD SHX Text

CODE INFORMATION

AutoCAD SHX Text

ALL DIMENSIONAL LUMBER, PLYWOOD, PARTICLE BD., FURRING AND BLOCKING SHALL BE

AutoCAD SHX Text

CUTTING HAS EXPOSED ANY UNFINISHED SURFACES. REPAIR ANY DAMAGE TO EXISTING

AutoCAD SHX Text

FINISH TO ORIGINAL CONDITION. EXTEND/REFINISH ALL FRAMES, BASE AND TRIM WHERE

AutoCAD SHX Text

DAMAGE. WHERE EXISTING WORK IS TO BE REMOVED OR ALTERED, RESTORE ADJACENT

AutoCAD SHX Text

SHALL BE PROTECTED BY ALL SUITABLE MEANS NECESSARY TO PREVENT OR MINIMIZE

AutoCAD SHX Text

CONTRACT" (N.I.C.). EXISTING WORK ADJACENT TO, OR IN THE AREA OF NEW WORK

AutoCAD SHX Text

FOR THE WORK DESCRIBED IN THESE DOCUMENTS UNLESS CLEARLY NOTED "NOT IN

AutoCAD SHX Text

CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS AND EQUIPMENT

AutoCAD SHX Text

TO DS ARCHITECTS, INC. PRIOR TO BEGINNING ANY WORK OR FABRICATION.

AutoCAD SHX Text

RESPECT TO THE WORK DESCRIBED IN THESE DOCUMENTS. REPORT ANY INCONSISTENCIES

AutoCAD SHX Text

CONTRACTOR(S) SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND DIMENSIONS WITH

AutoCAD SHX Text

ALL INTERIOR ROOM FINISHES TO MEET CLASS C FLAME SPREAD, 76-200 MAX.

AutoCAD SHX Text

CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES

AutoCAD SHX Text FREE OF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR

AutoCAD SHX Text

AND SHALL BE STORED IN A LOCATION APPROVED BY THE LANDLORD. NO PERSONAL RADIOS

AutoCAD SHX Text

SHALL BE ALLOWED IN OCCUPIED BUILDINGS.

AutoCAD SHX Text

WORK AND RESTORE TO ORIGINAL CONDITION.

AutoCAD SHX Text

PRESSURE TREATED/U.L. CERTIFIED NON-COMBUSTIBLE.

AutoCAD SHX Text %%uGENERAL NOTES & SPECIFICATIONS

AutoCAD SHX Text

ITEMS. IF THE OWNER DOES NOT EXERCISE THAT RIGHT THEN DISPOSE OF ALL DISCARDED

AutoCAD SHX Text

THE BUILDING OWNER SHALL HAVE THE "RIGHT OF FIRST REFUSAL" OF ANY SALVAGED

AutoCAD SHX Text

ITEMS IN A LEGAL, OFF SITE, MANNER.

AutoCAD SHX Text

DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. ALL DIMENSIONS ON FLOOR

AutoCAD SHX Text

PLAN ARE TO FACE OF GYPSUM BOARD UNLESS NOTED OTHERWISE.

AutoCAD SHX Text

%%UCONSTRUCTION:

AutoCAD SHX Text

COMMERCIAL CODES CURRENTLY

AutoCAD SHX Text ICC/ANSI A117.1. 2009 & MICHIGAN BARRIER FREE DESIGN LAW OF PUBLIC ACT 1 OF 1966 AS AMENDED

AutoCAD SHX Text

IN EFFECT

AutoCAD SHX Text

COMMERCIAL: MPC 2015 (MICHIGAN PLUMBING CODE 2015)

AutoCAD SHX Text

MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS 2015

AutoCAD SHX Text MICHIGAN ENERGY CODE, PART 10a. RULES (ANSI/ASHRAE/IES STANDARD 90.1-2013)

AutoCAD SHX Text REMOVE AND DISPOSE OF EXISTING SURFACE MOUNTED GYPSUM BOARD CEILING LIGHT FIXTURE. INSTALL NEW LIGHT FIXTURE IN SAME LOCATION. NEW GYPSUM BOARD CEILING SURFACE MOUNTED LIGHT FIXTURE BY 'KENALL' (KENALL.COM) MIGHTY MAC SSA SERIES #SSA4/145L35KDVJ/1WL.

AutoCAD SHX Text

MICHIGAN ELECTRICAL CODE BASED ON 2014 N.E.C. WITH PART 8 STATE AMENDMENTS

AutoCAD SHX Text

FOR EXISTING BUILDINGS 2015

AutoCAD SHX Text

UNIT SHOWER

AutoCAD SHX Text

RENOVATIONS

AutoCAD SHX Text

FILE NO. 472/17471.JAG

AutoCAD SHX Text

INDEX NO. 60230

AutoCAD SHX Text

%%UU.S. & EXPRESS MAIL ADDRESS

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT & BUDGET

AutoCAD SHX Text

STATE FACILITIES ADMINISTRATION

AutoCAD SHX Text

DESIGN AND CONSTRUCTION DIVISION

AutoCAD SHX Text

3111 WEST ST. JOSEPH STREET

AutoCAD SHX Text

LANSING, MI 48917

AutoCAD SHX Text

JOEL GORDON, PROJECT DIRECTOR

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

STATE FACILITIES ADMINISTRATION, DESIGN AND CONSTRUCTION DIVISION

AutoCAD SHX Text

P.O. BOX 30026

AutoCAD SHX Text

LANSING, MI 48909

AutoCAD SHX Text

TELEPHONE NUMBER: (517) 242-0761

AutoCAD SHX Text

EMAIL: GORDONJ1@MICHIGAN.GOV

AutoCAD SHX Text

ALTERNATES

AutoCAD SHX Text ALTERNATE NO. 1: INDICATED DASHED LINE REPRESENTS TO PROVIDE AND INSTALL 14 GAUGE STAINLESS STEEL WALL MOUNTED FLOOR TO CEILING LINER COVERING OVER INDICATED EXISTING TO REMAIN PORCELAIN TILED WALL PARTITIONS AS REQUIRED FROM FLOOR TO CEILING. LINER COVERING TO BE INSTALLED USING STAINLESS STEEL DRIVE PINS. PROVIDE STAINLESS STEEL DRIVE PINS ALONG VERTICAL EDGES EVERY 12" O.C. FROM FLOOR UPWARDS AND 6" O.C. FROM VERTICAL OUTER EDGES OF LINER COVERING HORIZONTALLY AT TOPS AND BOTTOMS AND THEN ALSO IN THE CENTER OF LINER COVERING (SEE ELEVATIONS). TORX DRIVE SCREWS ARE FORBIDDEN.

AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: BARRIER FREE SHOWERS TO HAVE TOUCH SENSOR (TS) LOCATED ON SAME WALL AS SHOWER HEAD.

AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: REWORK OR ABANDON EXISTING SHOWER VALVE AS REQUIRED FOR INSTALLATION OF NEW ELECTRONIC SHOWER VALVE (SV).

AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: EXACT PLUMBING SIZE AND CONFIGURATION NEEDED TO CONNECT THE NEW ELECTRONIC IN LINE SHOWER VALVE (SV) TO THE EXISTING SHOWER HEAD IS TO BE DETERMINED IN THE FIELD.

AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: EXACT PATH FOR LOW VOLTAGE WIRE FROM TOUCH SENSOR (TS) TO CONTROLLER TO BE DETERMINED IN FIELD BY INSTALLER.

AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: REMOVE AND REPLACE EXISTING SHOWER VALVES AS REQUIRED FOR ALL SHOWER CLUSTERS WITH THE FOLLOWING:

AutoCAD SHX Text NEW AC CONTROLLERS (AC) USING EITHER 'I-CON' NEXUS MODEL - 4 I/O AC CONTROLLER #CTR-X12-AC-04 SERIES OR NEXUS MODEL - 8 I/O AC CONTROLLER #CTR-X12-AC-08 SERIES BASED ON SHOWER VALVE QUANTITY

AutoCAD SHX Text 'I-CON' TRUTOUCH MODEL FORCE ACTIVATED TOUCH SENSOR (TS) #SEN-1501 (LEAD CABLE LENGTH TO BE DETERMINED BY INSTALLER)

AutoCAD SHX Text

'I-CON' ELECTRONIC IN-LINE SHOWER VALVE (SV) #VLV-SHW-5775-0808-S-0914-002

AutoCAD SHX Text

DRAWING INDEX

AutoCAD SHX Text A-1

AutoCAD SHX Text

LEGEND SHEET

AutoCAD SHX Text

ELEVATIONS

AutoCAD SHX Text

FLOOR / CEILING PLANS

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text A-4

AutoCAD SHX Text A-2

AutoCAD SHX Text A-3

AutoCAD SHX Text

DETAIL

AutoCAD SHX Text A-5

AutoCAD SHX Text

LOCATION

AutoCAD SHX Text

OF SITE

AutoCAD SHX Text

N. CROSWELL RD.

AutoCAD SHX Text

E. MONROE RD. / 46

AutoCAD SHX Text

ST. LOUIS, MI 48880

AutoCAD SHX Text

8585 N. CROSWELL RD.

AutoCAD SHX Text

%%USUITE LOCATION PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

LOCATION PLAN

AutoCAD SHX Text

HUBBARD ST.

AutoCAD SHX Text

N. UNION RD.

AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: REMOVE PORTION OF MASONRY WALL AS REQUIRED FOR INSTALLATION OF AND FUTURE SERVICING OF TOUCH SENSOR.

AutoCAD SHX Text PORTION OF ALTERNATE NO. 2: PROVIDE 14 GAUGE TYPE 304 STAINLESS STEEL PLATE WITH BRUSHED FINISH TO COVER MASONRY ACCESS HOLE OPENING (SIZE TO BE DETERMINED) FOR TOUCH SENSOR (TS) WITH FOUR (4) SCREWS TYPICAL IN JAN. ROOM. NO STEEL PLATE REQUIRED FOR TOUCH SENSOR BACKING UP TO PLUMBING CHASE.

Sheet Number of

Dwg.

Scale

Issued for

Checked

Date By

Project Number

Drawn

Drawing Title

P ro je c t

CLARKSTON, MI

7300 DIXIE HWY.

Seal

PHONE

FAX

PHONE

248.605.2030 248.605.2030

48346 #600

WEB DSARCHITECTS.COM

ST

. LO

UI

S C

OR

RE

CT

IO

NA

L

FA

CI

LIT

Y -

HO

US

IN

G U

NI

T

N C

R O

S W

E L L R

D

S T

L O

U

IS

M

I

SITE PLAN

18-40-129

BKO

DJS

OWNER REVIEW 11-29-18 DJS

BID 1-2-19 DJS

NO SCALE

ST. LOUIS CDs

A-2

BUILDING 5

RE

NO

VA

TIO

NS

SH

OW

ER

BUILDING 1

BUILDING 2

BUILDING 3

BUILDING 4

BUILDING 6

BUILDING 7

BUILDING ENTRY

VISITORS

PARKING

LOT

AutoCAD SHX Text

%%USITE NOTES

AutoCAD SHX Text

AutoCAD SHX Text

%%USITE PLAN

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

NORTH

AutoCAD SHX Text BUILDINGS 1 - 7 EACH CONTAIN 8 SHOWERS, WITH 4 ON THE FIRST LEVEL AND 4 ON THE SECOND LEVEL, WITH 2 ON THE LEFT AND 2 ON THE RIGHT OF EACH LEVEL. THE BARRIER FREE SHOWERS ARE LOCATED ON THE FIRST LEVEL OF BUILDINGS 1 AND 7 AND ON THE RIGHT. THERE ARE 56 SHOWERS IN TOTAL.

AutoCAD SHX Text

Sheets and Views
ST.LOUIS CORRECTIONAL FACILITY CDs-LEGEND
ST.LOUIS CORRECTIONAL FACILITY CDs-SITE PLAN
ST.LOUIS CORRECTIONAL FACILITY CDs-FLR CEIL
ST.LOUIS CORRECTIONAL FACILITY CDs-ELEV'S
ST.LOUIS CORRECTIONAL FACILITY CDs-DETAIL

File details come from the government source that posted it. Updated .