st. tammany parish sb Bid1899ModularBuildingLeaseBoyetJuniorHigh.pdf

PDF 9 MB Posted

Attached to
Modular Classroom Buildings for Boyet Junior High School
Solicitation number
1899
Issued by
Washington Parish, Louisiana

About this file

This is a sealed bid solicitation issued by the St. Tammany Parish School Board in Covington, Louisiana for the lease and rental of modular classroom buildings to support Boyet Junior High School in Slidell, Louisiana. The project requires three modular buildings: a 12-classroom building with restrooms, internal hallway, and two-hour fire wall separation (Building A with approximately 11,765 gross square feet comprising 13 modules); a choral building (Building B with approximately 775 gross square feet comprising 4 modules); and a band building (Building C with approximately 1,505 gross square feet comprising 2 modules). The specifications call for new buildings or like-new condition buildings manufactured within no less than three years of the bid date, all approved by the Louisiana State Fire Marshal and compliant with applicable codes including the International Building Code and NFPA standards. Bids were due by 2:30 p.m. CST on Friday, October 23, 2026, submitted either by registered mail to the St. Tammany Parish School Board Office at 321 North Theard Street, Covington, Louisiana 70433, or electronically through www.centralbidding.com. The bid opening was scheduled for October 23, 2026, with public reading of contents. Delivery and complete setup of all modular units were expected to be completed within 60 days of Notice to Proceed, anticipated for approximately February 2027. The lease term is structured as monthly payments beginning upon completion of setup, with two pricing options provided: Option 1 for new buildings with a 36-month lease term and Option 2 for like-new condition buildings with a 36-month lease term, plus separate line items for initial delivery and installation costs and dismantling and removal costs.

Bidders were required to provide a bid security in the form of an original, fully executed bid bond, certified check, cashier's check, or money order equal to five percent of the total price of whichever option represents the highest total cost; electronic bids required only a bid bond with original delivery within 48 hours of bid opening. The successful bidder must furnish a Performance Bond in the total amount of the order and a Certificate of Insurance within 15 calendar days after award including comprehensive general liability of $1,000,000 combined single limit, automobile liability with minimum limits of $1,000,000 per person and per occurrence, workers compensation with statutory limits of $1,000,000, and professional errors and omissions insurance of not less than $1,000,000 naming the School Board as additional insured. The bidder must possess a Louisiana State Commercial Contractor's License (Classification—Building Construction) and list the license number on the outside of the sealed bid envelope; bids totaling $50,000 or more require this license number. All bid prices must exclude sales tax as the St. Tammany Parish School Board is exempt under LA R.S. 47:301(8)(c). Liquidated damages of $1,000 per day apply for delays beyond the 60-day contract completion window, with time extensions considered for unforeseeable conditions. The School Board reserves the right to lease new buildings, accept bids for reconditioned units, or select any combination thereof, as well as to reject any and all bids and adjust quantities. Questions regarding the bid were to be submitted by email to construction@stpsb.org and received by 2:00 p.m. on Friday, October 16, 2026. Successful bidders must sign acknowledgment statements and submit affidavits of compliance with Louisiana Revised Statutes 38:2212.9, 38:2224, and 38:2227 as well as certification of non-discrimination against the firearm/ammunition industry within ten days after bid award. All disputes and claims are subject to exclusive venue and jurisdiction of the 22nd Judicial District Court for St. Tammany Parish, Louisiana.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ST. TAMMANY PARISH SCHOOL BOARD

COVINGTON, LOUISIANA

The St. Tammany Parish School Board will receive sealed bids until 2:30 p.m. CST on Friday, October 23, 2026, on Lease/Rent of Modular Classroom Buildings for Boyet Junior High School in accordance with the following instructions, attached specifications and drawings.

1. Bids shall be submitted on the enclosed bid form. All conventional paper bids shall be either hand delivered or sent by registered or certified mail with a return receipt requested to the St. Tammany Parish School Board Office located at 321 North Theard Street, Covington, Louisiana 70433, in a sealed envelope clearly marked on the outside "BID #1899 - MODULAR CLASSROOM BUILDINGS FOR BOYET JUNOIR HIGH SCHOOL– October 23, 2026." All bids arriving after this date and hour will be returned unopened to the bidders. The responsibility for timely delivery rests solely with the bidder. Bids delayed through any means of delivery service and arriving after the deadline will not be accepted. No bid may be withdrawn for at least thirty (30) days after the scheduled closing time for receipt of bids.

2. Bids may also be submitted electronically. Please find bid related materials and place electronic bids at www.centralbidding.com.

3. At the time set for the opening of bids, their contents will be publicly opened and read aloud for the information of bidders and others properly interested who may be present in person or by representative.

4. Prices shall include all engineering, documents for permitting, State of Louisiana Fire Marshal review and approval, on site installation, set-up, leveling, foundations, anchoring, skirting and delivery charges to Boyet Junior High School, 59295 Rebel Drive, Slidell, LA 70461.

5. Sales tax IS NOT to be included in your bid prices. St. Tammany Parish School Board is exempt from sales tax as provided by LA R.S. 47:301(8)(c). Sales tax exemption only applies to purchases between St. Tammany Parish School Board and the contractor/vendor. Sales tax exemption does not apply to purchases made directly by the contractor/vendor to other companies on behalf of the school board. Those purchases are not sales tax exempt.

6. The signature on the bid is that of an authorized representative as documented by the legal entity certifying the authority of the person by either Written evidence or a Corporate Resolution shall be submitted with bid.

7. ALL BIDS SHALL BE ACCOMPANIED BY A BID SECURITY IN THE FORM OF AN ORIGINAL,

FULLY EXECUTED BID BOND. CERTIFIED CHECK, CASHIER'S CHECK OR MONEY ORDER

IN THE AMOUNT OF FIVE PERCENT (5%) OF THE TOTAL PRICE OF EITHER OPTION 1 OR

OPTION 2, WHICHEVER OPTION IS THE HIGHEST TOTAL COST. BIDS WILL NOT BE

CONSIDERED UNLESS THE REQUIRED CHECK OR BID BOND IS ATTACHED.

8. If submitting bid electronically, then bid security must be in the form of an original, valid fully executed bid bond only. A copy of the bid bond must be included in your bid documents, and the original bid bond must be received by the St. Tammany Parish School Board Office within 48 hours of the bid opening. No cashier's check, certified check or money order will be accepted for an electronic bid. Failure to comply will cause your bid to be non-responsive.

9. A Performance Bond in the total amount of the order will be required from the successful bidder.

10. If the total of your bid is $50,000.00 or more, you must show your Louisiana State Contractor's

License number on the outside of your bid envelope.

11. In accordance with LA Revised Statute 38:2252, "Preference is hereby given to materials, supplies and provisions, produced, manufactured or grown in Louisiana, quality being equal to articles offered by competitors outside of the state." As a bidder you must indicate on your bid response if you are claiming a preference.

12. The successful bidder(s) shall furnish a Certificate of Insurance within fifteen (15) calendar days after award of bid but prior to delivery of merchandise. Certificate should provide for:

The Certificate of Insurance should provide the following:

a. Comprehensive General Liability - $1,000,000.00 combined single limit. Coverage to include premises, operations, contractor’s protective liability, products and completed operation, contractual liability.

b. Comprehensive General Automobile Liability Insurance with minimum limits of Bodily Injury – Each Person $1,000,000.00, Bodily Injury – Each Occurrence $1,000,000.00, Property Damage – Each Occurrence $1,000,000.00. Coverage shall be written to include all owned, non-owned and hired vehicles.

c. Workers Compensation – State of Louisiana, Employer’s Liability, Statutory requirements $1,000,000.00.

d. NOTE: The Registered Licensed Structural Engineer/Modular Vendor shall carry and provide not less than $1,000,000 of Professional Errors and Omissions Insurance naming St.

Tammany Parish School Board as additional insured.

13. Cash discounts, if offered, will be taken into consideration in determining the low bidder.

DISCOUNTS LESS THAN THIRTY (30) DAYS WILL NOT BE CONSIDERED IN MAKING AN

AWARD. Beginning date for discount period shall be determined by date of invoice or date of delivery of merchandise whichever occurs last.

14. It is the intent of the specifications to invite bids on high-quality merchandise. Mentioning a brand, manufacturer, and number is done only to establish the standard of quality desired. It is not the intent to eliminate brands of equal quality but instead to set forth and convey to prospective bidders the general style, type, character and quality of the product desired.

15. The School Board reserves the right to select a higher priced item where, in the judgment of the

School Board, such item is of superior quality or design or would be more suitable for the purpose intended. The School Board further reserves the right to adjust quantities by increasing or decreasing and to reject any and all bids.

16. The School Board reserves the right to obtain clarification of a vendor’s bid or to obtain additional information necessary to properly evaluate their bid.

17. Successful bidder must consent to and yield to the exclusive venue and jurisdiction of the 22nd Judicial

District Court for the Parish of St. Tammany and waive any and all claims of entitlement to removal of any case from this jurisdiction, including any removal to any Federal Court, in connection with bid.

18. Questions may be emailed to construction@stpsb.org. All questions must be received by 2:00 pm, Friday, October 16, 2026.

STEVE E. ALFONSO, JR.

Interim Superintendent

ST. TAMMANY PARISH SCHOOL BOARD COVINGTON, LOUISIANA

SPECIFICATIONS ON MODULAR BUILDINGS

It is the intent of the St. Tammany Parish School Board to rent/lease modular classroom building units which will be used to support needs at the school indicated on attached. Units are to be new and approved by the Louisiana State Fire Marshal and any other governing authorities. Bids and information will also be accepted in addition for units that meet all codes, have all necessary approvals and tags, and are in new or like-new condition and have been manufactured within no less than 3 years of the date of this bid.

This project consists of the fabrication, delivery, and set-up of all units required to provide for three (3) buildings to support: (A) Band, (B) Choral and (C) provide for a twelve (12) classroom building with internal hallway, restrooms for students and separate single ADA restroom for staff and a custodial closet as shown on the attached drawings.

Contractor is responsible for the design, engineering, permitting, transport and complete set-up (including but not limited to setting units, foundations, anchoring and blocking, and skirting of units) and demobilization of the units per the attached drawings at Boyet Junior High School, Slidell, LA. Modular Contractor is responsible for all materials necessary for proper blocking and anchoring of the modular building units and for skirting the units at the elevations indicated and in coordination with the Owner’s Separate Infrastructure Contractor.

Modular Contractor is not responsible for on-site walkways, canopies, electrical connections, water and sewer connections or special systems connections or added cabinetry, markerboards and tackboards.

However, Modular Contractor is to note that these items will be installed in or adjacent to the modular buildings. School system and/or other contractor will also add network wiring, access control, additional electrical, special system devices and wiring as necessary to support St. Tammany Parish Public School System’s classroom use.

Modular Contractor is responsible for all approvals and permits necessary to provide, transport and install the modular buildings. Modular Contractor shall also provide and coordinate and participate as needed with Owner/Infrastructure Contractor to provide any necessary information to authorities having jurisdiction of the development of the modular classroom buildings for issuance of all required building permits, inspections and final occupancy inspections. (Reference attached drawings)

Classroom modular buildings shall be designed and built to meet all latest edition of current applicable codes, shall have shop drawings and be built in accordance with these codes, shall be reviewed and approved by the Louisiana State Fire Marshal including the Industrial Building Review, NFPA Fire Safety, and IBC. At a minimum, modular classroom buildings should be capable of withstanding design loads in accordance with ASCE 7-16. Wind speed design should be per latest edition IBC code for the location in which the buildings are to be located.

Finishes are to be typical of modular building industry for use in a heavily utilized classroom setting. All exterior finishes shall match in color. Roof must carry a 10-year weather tightness warranty on the system and be in watertight condition. Modular Contractor shall have a local service provider certified in the type roofing system on the building that will respond to any roof leak reports within 24 hours throughout the lease term. NOTE: Successful bidder shall provide name of local service provider before signed lease/contract agreement. Floor finish of VCT tile is preferred. Each classroom shall have HVAC systems designed for the size, load and use of the building/classrooms. The systems are to be designed to maintain temperature when occupied within 2 degrees+/- of cooling 70 degrees; heating 72 degrees. Modular Contractor is to be responsible for issues with the leased units relative to HVAC, Roof or Wall Leaks, or other building related issues during the lease period. Lessee will change HVAC filters and do regular general cleaning. Classroom door hardware provided by Modular Contractor is to be classroom storeroom function and to be keyed same for all classrooms. The exterior door hardware provided by Modular Contractor is to be keyed to the school key system and have electric strikes and panic hardware to work with St. Tammany Parish School Board Access Control System.

Classroom Modular Buildings are to be certified as having no asbestos or formaldehyde containing materials and shall have V.O.C. levels below those recommended by the EPA. Buildings shall have no mold and any materials showing signs of such are to be fully replaced and the building tested by Owner's environmental consultant at the Contractor's expense.

Protect modular buildings from damage during delivery, storage, and handling. Reinforce, stiffen, and brace modular buildings to withstand handling, delivery, and erection stresses. Lift fabricated assemblies to prevent damage or permanent distortion. Buildings are to be installed plumb, square, true to line and with connections securely fastened to foundations in accordance with manufacturer's written instructions, and any requirements of authorities with jurisdiction. Plumbing rough-in is to be manifolded by Modular Contractor for connection by Infrastructure Contractor.

Building site is located at a grassy field area with varying grade elevations. Modular Contractor is to provide foundations relative to grade to provide for level finish floor elevation across all units combined to act as one building. Infrastructure Contractor is to prepare site for Modular Contractor installation of foundations and buildings. Trees adjacent (if applicable) to general building area are to be protected.

Modular Building is to be utilized for operation of St. Tammany Parish Public School System Classrooms.

As such, the use of the building areas, will be heavy. Owner will do regular daily dust mopping, regularly scheduled mopping and yearly waxing of flooring- custodial service as typical to the campus.

NOTE: Modular Contractor is to anticipate cost of any repairs or replacements needed upon return of the units. Owner will not pay additional costs upon return for these repairs and replacements due to typical heavy use as a classroom wing.

Successful bidder is to coordinate with on-site Infrastructure General Contractor and deliver and set-up modular units to create one complete building in alignment with on-site Infrastructure GC schedule.

Delivery and all set up is expected to be completed within 60 days of Notice to Proceed on site anticipated to be approximately on or around February, 2027.

Delivery of units shall be coordinated to not impact or interfere with daily school car and bus traffic or school events.

SCHOOL HOURS:

Boyet Junior High School hours are 8:55-3:55 M-F.

Adjacent School, Little Oak Middle School hours are 7:35 -2:35 M-F.

It should be noted that both schools utilize the same routing for car and bus traffic on Rebel Drive and car line stacking on the limestone perimeter drive located on Boyet Junior High School property. This driveway is adjacent to the modular buildings site location.

UPCOMING SCHOOL HOLIDAYS:

Thanksgiving - November 23-27,2026 Winter Break - December 21,2026 -January 4, 2027 Martin Luther King Holiday - January 18, 2027 Mardi Gras - February 8-12, 2027 Spring Break - March 26-31,2027 Last Day of School Year May 26. 2027

Monthly lease term is to start at completion of setup of units such that the building may be occupied.

Submittals:

Complete shop drawings and calculations bearing the seal of a registered structural engineer in the State of Louisiana submitted and approved by State of Louisiana Fire Marshal including IBC review. Foundation and anchoring details shall be included and stamped by the engineer. (All foundations and anchoring required shall be installed per stamped drawings by Modular Contractor.) All calculations, details and drawings shall be stamped by the same engineer and engineer shall have a minimum of 5 years' documented experience designing modular buildings similar to those required for this project.

Building documentation must also include a stamped letter from a licensed electrical engineer certifying that the lighting level meets the requirements of Department of Health and Hospitals and Code requirements. The engineer of record shall carry and provide not less than $1,000,000 of Professional Errors and Omissions Insurance naming the Owner as additional insured. Shop drawings should include details showing framing, extent of any pre-fabrication, and including details or attachments of member to member within system, bridging, attachment to foundations and other framing systems.

A drawing of layout of “like-new” buildings shall be submitted with the bid. These layouts are necessary to determine how the “like-new” buildings will affect the infrastructure scope of work.

Complete building product and warranty information shall be submitted along with the roof 10-year weather tightness warranty on the system.

Schedule for production, delivery and complete setup of units shall be provided.

Modular Contractor (Lessor) will be required to sign a statement indicating that the requirements indicated in this bid are acknowledged as part of the lease agreement. (see enclosed sample statement)

Non-Asbestos or other Hazardous Materials Certificate signed by Lessor: Classroom Modular Buildings are to be certified as having no asbestos or formaldehyde containing materials and shall have V.O.C.

levels below those recommended by the EPA.

A copy of your company's standard lease agreement/contract should be included with your bid which will be subject to review and/or revisions by School Board counsel. Jurisdiction of any lawsuits or other claims will be State of Louisiana, St. Tammany Parish, 22nd Judicial District.

Modular Contractor shall possess a Louisiana State Commercial Contractor’s License (Classification – Building Construction) Louisiana Contractor’s License No. must be listed on the outside of the sealed bid.

Attachments:

Modular Classroom Buildings Specifications Sample Modular Classroom Wing Plan Site Plan Infrastructure For Modular Wing Plans (for information) Acknowledgment of Requirements in Bid Affidavit of Compliance with Louisiana R.S. 38:2212.9, 38:2224 & 38:2227 Affidavit of Certification of Non-Discrimination Against Firearm/Ammunition Industry

ST. TAMMANY PARISH SCHOOL BOARD COVINGTON, LOUISIANA

BID FORM FOR MODULAR BUILDINGS’ LEASE/RENT

Boyet Junior High School

October 23, 2026, 2:30 p.m.

Company Name:

Address:

ITEM 1

Total of Units Required to Provide for a 12-classroom Building with Restrooms, Internal Hallway and Fire Wall (Bldg. A), Choral Building (Bldg. B) and Band Building (Bldg. C) as shown on the attached drawings

OPTION 1 – Total Price for Lease 36 months of (New) Buildings.

Price per month/building 12 Classroom Wing with Restrooms, Internal Hallway and Fire Wall: ________

Price per month/building Choral:

Price per month/building Band:

Total Price 36 Month Lease all Buildings: ________

OPTION 2 - If available, provide total price for Lease 36 months of "like new" condition buildings.

Price per month/building 12 Classroom Wing with Restrooms, Internal Hallway and Fire Wall: _______ Price per month/building Choral:

Price per month/building Band:

Total Price 36 Month Lease:

Provide Year “like new” Buildings were Manufactured:

ITEM 2

Total Price for initial delivery, installation, set-up, leveling, anchoring and skirting all units to create complete building setup:

ITEM 3

Total Price for dismantling and removing all units to remove buildings from site:

ESTIMATED DATE OF DELIVERY: _____________________________

Acknowledgement of Addenda (if applicable):

Successful bidder to coordinate with on-site Infrastructure General Contractor and deliver and set-up modular units to create three complete buildings in alignment with on-site Infrastructure GC schedule.

Delivery and all set up are expected to be completed within 60 days of Notice to Proceed on site anticipated to be approximately on or around mid/end of January, 2027.

Liquidated damages of $1000.00 per day shall apply for any days beyond this contract time. Time extensions for unforeseeable conditions will be considered should any occur.

The St. Tammany Parish School Board reserves the right to lease new buildings or to accept alternate bid to lease reconditioned units, or any combination, whichever option is most advantageous to the School Board.

Successful bidder shall be required to submit the following enclosed Affidavit’s within ten (10) days after bid award. (Affidavit of Compliance with Louisiana R.S. 38:2212.9, 38:2224 & 38:2227 and Affidavit of Certification of Non-Discrimination Against Firearm/Ammunition Industry)

BID SUBMITTED BY:

Name of Company Date of Bid

Mailing Address Discount (If Applicable)

City, State, Zip Code Typed Name of Representative

Telephone Number Signature of Representative

Email Address of Representative

Modular Classroom Buildings - Specifications

1.1 SUMMARY

A. Section Includes:

1. Fabricated wood-construction modular classroom buildings.

1.2 ACTION SUBMITTALS

A. Product Data:

1. Fabricated wood-construction modular classroom buildings.

B. Shop Drawings: For modular classroom buildings. Include plans, elevations, sections, details, accessories, and fastening and anchorage details.

C. Delegated Design Submittals: For modular classroom buildings, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation.

1. Modular buildings shall be built in compliance with the International Building Code, Americans with Disabilities Act, International Plumbing Code, International Mechanical Code, International Energy Conservation Code, and the National Electric Code. Modular buildings shall be engineered to meet local floor and roof load requirements and shall have electrical, heating and cooling loads sized in accordance with nec and IBC codes.

2. Indicate connections to foundations.

1.3 INFORMATIONAL SUBMITTALS

A. Sample Warranty: For special warranty.

PART 2 – PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

A. Delegated Design: Engage a qualified professional engineer to design modular classroom buildings.

B. Structural Performance: Modular classroom buildings to withstand the following loads and stresses within limits and under conditions indicated in accordance with ASCE/SEI 7.

1. Loads: As indicated on Drawings.

C. Thermal Movements: Allow for thermal movements from ambient and surface temperature changes.

D. Electrical Components, Devices, and Accessories: Listed and labeled in accordance with NFPA 70 and marked for intended location and application.

E. Regulatory Requirements: Comply with applicable provisions in the U.S. Department of Justice's "2010 ADA Standards for Accessible Design".

2.2 MODULAR CLASSROOM BUILDINGS

A. Basis of Design Product: Provide the following or a similar complete product system meeting requirements indicated by a comparable manufacturer.

1. Basis of Design Manufacturer: Palomar Modular Buildings

a. Layout: (A) Band: @ 64’-0”x 23’-6”

(B) Choral: @ 33’-0” x 23’-6”

(C) 12 Classroom Wing Building: @ 69’-9.5” x 168’-6” with 2 hour fire wall assembly as shown on drawing sheet A001-P0 and A005-P0

b. Size: (A) @1505s.f. (B) @775 s.f. (C) @ 11,765 s.f.

c. Number of Modules/Units: (A) 2 (B) 4 (C) 13

d. Building Type: VB

e. Floors:

i. Frame type: Outrigger sized to meet design criteria

ii. Running gear: tires, axles and hitches removed and stored under unit or as otherwise coordinated with Owner

iii. Wood joists: 2 x 10 southern yellow pine @16” o.c.

iv. Insulation: R-30 fiberglass unfaced batt

v. Decking” ¾” Sturdi-floor T&G

vi. Moisture Protection: bottom board woven, reinforced poly

vii. Floor covering: 12 in commercial vinyl tile

viii. Wall base: 4 inche vinyl cove

f. Exterior Walls:

i. Wood studs: 2x6 @16” o.c. with double top and single bottom plates

ii. Insulation R-19 fiverglass unfaced batt

iii. Exterior sheathing: 7/16” OSB

iv. Moisture control: building wrap

v. Exterior siding: 29 ga steel pre-finished, panel loc+

vi. Vinyl gyp wall finish: 5/8” vinyl covered gypsum board

g. Interior Walls:

i. Wood studs: 2x4 @16” o.c. with double top and single bottom plates

ii. Insulation: R-11 unfaced fiberglass batt

iii. VCG wall finish: 5/8” vinyl covered gyp

iv. Special wall construction: 45 minute rated walls at custodial closet

v. Restroom wall finish: Class "c" FRP, full height

h. Roof:

i. Type: wood with laminated plywood mate beams

ii. Std. Wood rafters: 2x10 @ 24 oc

iii. Insulation: R-30, unfaced

iv. Decking: 5/8" OSB plus FR adhesive for class C roof

v. Roof covering: EPDM, 45 mil membrane or other acceptable roofing system

vi. Ceiling: 2x2 suspended ceiling, USG or equal radar tile, 15/16 grid

i. Doors:

i. Exterior steel doors:

a. (qty: 7) 3-0 / 6-8 steel door, knock down frame, closer, painted 18ga door ,16ga frame, insulated

b. (qty: 2) removable mullion

ii. Interior doors:

a. (qty: 15) 3-0 / 6-8 pre finished solid core wood door / 18ga "timely" knock down steel frame rated per State of Louisiana Code and FM requirements

b. Special doors: (qty: 1) 45 minute rated at custodial closet. (qty: 2) 90 minute rated at 2 hour wall separation shown on drawings on magnetic hold opens with Fire Alarm System

iii. Door glazing: (qty: 7) door glass: 6x27" (ext) and (qty:12) door glass 6”x18” at classroom doors

iv. Ext door hardware: (qty: 7) pmb standard pull/standard panic hardware and electric strikes (Owner will change out the hardware to be compatible with Owner Access Control System)

v. Int door hardware: (qty: 12) classroom, Offices, Data, and Custodial doors to have Storeroom Function lever handle locksets and to be keyed same for all classrooms (qty:1) Staff ADA RR to have indicator lock “occupied”/”unoccupied” with thumb-turn lock on interior side; (qty:2) Push Pull for Girls’ and Boys’ Restrooms

vi. Door stops: floor mounted

j. Windows:

i. Exterior windows: (qty: 15) 3-0 / 5-0 dual pane, low-E, clear glazing, single hung vinyl frame (minimum 1 per classroom, 2 in Band)

ii. Blinds: (15 ea.) 1'' metal mini blinds

k. Electrical:

i. Conduit: non-metallic tubing (ENT)

ii. Receptacles: duplex receptacles, 20 amp, unbreakable covers

iii. GFI receptacles: (4) ea 20 amp

iv. Exterior receptacles: (2) ea, convenience duplex with cover

v. Child/tamper/hospital: per code

vi. Dedicated receptacles: 20A w/receptacle. (electric water cooler)

vii. Dedicated receptacles: 50A connection (40 gal + water heater, etc.)

viii. Panels: (4) 100A-200A, 10KAIC, 1P, clip on breakers

ix. Room lighting: 2x4 LED fixtures

x. Emergency lights: (3) emergency - 2 bulb LED with remote head

xi. Exit lights: (3) exit lights, LED w/battery backup

xii. Exterior lights: (2) exterior porch, LED at each exit

xiii. Occupancy sensor, single: (14) each wall mounted

xiv. Empty box & conduits: (32) stubbed to ceiling, 3/4".

l. Fire Protection:

i. Not included. Fire Alarm System to be installed by Other Contractor.

m. Plumbing:

i. Supply piping: CPVC

ii. Waste piping: PVC/ SCH 40 DWV

iii. Toilets: (10) toilet, standard height, 3 ADA, floor mounted, tank type

iv. Urinals: (3) urinal, standard

v. Flush valves: flush valve- battery operated per toilet fixture, manual per urinal

vi. Lavatories: (13) lavatory, wall mount or drop-in w/single lever faucet

vii. Sinks: (1) mop sink - fiberglass, floor mounted

viii. Floor drains: (3) ea floor drain, with trap primer & access door

n. Water fountains:

i. (1) ea elec water cooler with 2 stations - hi-lo with bottle filler

o. Water heaters:

i. (1) ea 40 gal water heater, electric w/overflow pan

ii. (1) ea recirculation pump

iii. (1) ea expansion tank: 5-10 gal

p. Accessories:

i. (7) ea 18" x 36" SS framed mirrors – Owner provided

ii. (3) ea set hc grab bars for HC toilet – Owner provided

iii. (8) ea toilet paper holder- single surface mounted – Owner provided

q. Toilet partitions: (8) ea toilet partitions - powder coated steel, floor mounted, overhead braced,( 1) wall mounted urinal screen

r. HVAC:

i. Std. Units: wall mounted packaged HVAC with electric heat strip, 1 phase, sized per design requirements

ii. Supply air: ducted

iii. Ducting: flex duct

iv. Return air: at return, jump ducts as required

v. Thermostats: 7 day programable with occupant overide

vi. Diffusers: adjustable diffusers

vii. Filter: at unit; provide new set of clean filters at turn over to Owner

s. Exhaust fans:

i. (1) 80 CFM exhaust fan/light combo

ii. (2) 300 CFM exhaust fans

t. Millwork:

i. Not included. Will be installed by Owner/Other Contractor

u. Ship Loose:

i. Close up: close-up plastic for skirting or belly band

ii. Skirt framing: pressure treated wood framing (36" ht)

iii. Skirting: 29 ga metal

v. Set up:

i. Anchors, auger, straps, clips

ii. 2" x 8" pt shims & oak wedges

iii. Foundations and piers as required

PART 3 – EXECUTION

3.1 FABRICATION

A. Manufacture all modules in accordance with state and customer approved drawings.

3.2 EXAMINATION

A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances, including foundations and CMU Block piers; critical dimensions; and other conditions affecting performance of the Work.

B. Examine roughing-in for electrical and plumbing systems to verify actual locations of connections before control booth installation.

C. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work.

D. Proceed with installation only after unsatisfactory conditions have been corrected.

3.3 DELIVERY

A. Truck / Translift as required to set all modular buildings in accordance with a mutually agreed site plan and staging schedule and area.

B. Provide all permits required for transportation of the modules over the road.

3.4 INSTALLATION

A. Make final modular mate line structural connections and finishes including electrical and HVAC crossovers provided by modular classroom building manufacturer in the field.

B. Provide and install pressure-treated wood framing with siding to match exterior of building including ventilation & skirt panel access.

C. Install in accordance with manufacturer's written instructions.

D. Install with interior floor surface at elevation indicated on drawings.

E. Set classroom buildings plumb and aligned.

F. Coordinate with Owner’s “Infrastructure” Contractor on site to achieve a complete project with

Modular Classroom Building Infrastructure and Walkways for all systems and other equipment that must be installed in or adjacent to or connected to the Modular wing so that the project(s) are complete and pass inspections for occupancy.

3.5 ADJUSTING

A. Adjust doors, operable windows, and hardware to operate smoothly, easily, properly, and without binding. Confirm that locks engage accurately and securely without forcing or binding.

B. Adjust interior and exterior lighting controls.

C. Lubricate hardware and other moving parts.

D. After completing installation, inspect exposed finishes and repair damaged finishes.

E. Test all HVAC units and provide clean filters in all at turn over to Owner.

End of Specification Attachment

ACKNOWLEDGMENT OF REQUIREMENTS IN BIDS

I, , [Insert Name], as a representative of ___________________________, acknowledge that [Insert Company Name] has entered into a lease agreement as Lessor with the St. Tammany Parish School Board as Lessee for the Leasing of Modular Classroom Building for STPSB Project No.

[Insert STPSB Project No.] at [Insert School Name and Address]. I further acknowledge that I have reviewed all requirements, specifications, and instructions in the Request for Quotes, including any referenced attachments, issued by the St. Tammany Parish School Board for the Leasing of Modular Classroom Building for STPSB Project No. [insert STPSB Project No.] I affirm that, in executing the lease agreement, [Insert Company Name] will comply with all requirements, specifications, and instructions contained in this Bid.

Signed this day of , 2026.

REPRESENTATIVE

Modular Company

Certification of Non-Discrimination Against Firearm/Ammunition Industry

State of Louisiana Project Name: Boyet Junior High School Infrastructure and Walkways for Modular Wing

Parish of Project Number: 2511

AFFIDAVIT

BEFORE ME, the undersigned authority, duly commissioned and qualified within and for the State and Parish aforesaid, personally came and appeared duly authorized and representing , who being by me first duly sworn deposed and said that he has read this affidavit and does hereby agree under oath to comply with all provisions herein as follows:

Section 2216.1 of Part II of Chapter 10 of Title 38 of the La. Revised Statues of 1950 as amended. Specifically, the Affiant states and certifies that:

(1) Affiant does not have a practice, policy, guidance, or directive that discriminates against a firearm entity or firearm trade association based solely on the entity’s or association’s status as a firearm entity or firearm trade association; and

(2) Affiant will not discriminate against a firearm entity or firearm trade association during the term of the contract based solely on the entity’s or association’s status as a firearm entity or firearm trade association.

Affiant Signature:

Affiant Print Name:

SWORN TO AND SUBSCRIBED before me this day of , 2026.

NOTARY PUBLIC

Note: This form is to be removed, fully executed and delivered by the apparent low bidder within ten (10) days after the designated time that bids are to be opened. This form shall be delivered to the same location that bids are to be accepted.

AFFIDAVIT OF COMPLIANCE WITH LOUISIANA REVISED STATUTES 38:2212.9, 38:2224 AND 38:2227

STATE OF

PARISH/COUNTY OF

PROJECT NO. 2511

NAME Boyet Junior High School, Infrastructure and

Walkways for Modular Wing

LOCATION Slidell, LA

AFFIDAVIT

BEFORE ME, the undersigned authority, duly commissioned and qualified within and for the state and parish aforesaid, personally came and , representing , being by me first duly sworn deposed and said that he/she has read and signed this affidavit and he/she does hereby attest, under oath, as follows:

(1) That affiant and his/her firm employed no person, corporation, firm, association, or other organization, either directly or indirectly, to secure the public contract for the above-referenced project with the St. Tammany Parish School Board under which he will, if awarded the contract, receive or have received payment, other than persons regularly employed by the affiant whose services in connection with the construction, alteration or demolition of the public building or project or in securing the public contract were in the regular course of their duties for affiant;

(2) That no part of the contract price to be received or received by affiant or his/her firm was paid or will be paid to any person, corporation, firm, association, or other organization for soliciting the contract, other than the payment of their normal compensation to persons regularly employed by the affiant whose services in connection with the construction of the public building or project were in the regular course of their duties for affiant;

(3) That neither affiant, nor any partner, incorporator, director, manager, officer, organizer, or member who has a minimum of ten percent ownership in the bidding entity, has been convicted of, or has entered a plea of guilty or nolo contendre to any crimes enumerated in Louisiana Revised Statute 38:2227, or equivalent federal crimes; and

(4) That neither affiant, nor any individual with an ownership interest of five percent or more in his/her firm has been convicted of, or has entered a plea of guilty or nolo contendre to any state felony crime or equivalent federal felony crime committed in the solicitation or execution of a contract or bid awarded under the laws governing public contracts as described in Louisiana Revised Statute 38:2212.9.

Bidder or representative to sign and type name below signature.

Affiant

SWORN TO AND SUBSCRIBED BEFORE ME THIS day of , 2026.

NOTARY PUBLIC

WH

X

X

F R

E E

Z E

P R

O O

F H

B

DNX

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

X X

X X

X X

X X

X

X XX X X X

X X

X X

X

X X

X X

X X

X X

X X

X

X

X

X

X X

X X

X X

X X

X

X

X X

X X

X

X

X X

X X

F L O O D

Z O N E

"C

F L O O D

Z O N E

"B

FLOOD ZONE "B"

FL

O O D

Z O N E "B

FL

O O D

Z O N E

"A 1"

FL

OO

D

ZO

N E "C

FL

OO

D

ZO

N E "B

FLOOD ZONE "A1"

STAFF RR CUSTODIAL

VARIES PER MANUF.

69' - 9 1/2" 1" / 12"

± 24' - 1 1/4"

EXISTING GYMNASIUM

20' - 1 1/4" (20' MIN.) TO

BY OTHERS/NOT IN SCOPE

COVERED WALKWAYS AND RAMP

LOCATION OF ADDITION

IF ALT 1 ACCEPTED

729 SF

Classroom

750 SF

Classroom

750 SF

Classroom

750 SF

Classroom

729 SF

Classroom

729 SF

Classroom

729 SF

Classroom

750 SF

Classroom

729 SF

Classroom

750 SF

Classroom

732 SF

Classroom

750 SF

Classroom

720 SF

Choral Building leased

1418 SF

Band Building leased

C

LA

SS

R O

O M

M O

D U

LA

R

B U

IL

D

IN

G le a s e d

B Y

O T

H E

R S

/N O

T I

N S

C O

P E

U N

C O

V E

R E

D R

A M

P F

O R

E G

R E

S S

0' - 0"

2' - 6" F.V.

V A

R

IE

S P

E R

M A

N U

F

8'

/8

1" / 12"

ALL MODULARS ARE TO BE DELIVERED AND SET IN PLACE BY THE MODULAR

LEASING COMPANY. INCLUDE SKIRTING AND ANY OTHER ON SITE INSTALLS

FOR A FINISHED BUILDING.

OWNER'S CONTRACTOR WILL INSTALL ACCESS CONTROLS, SECURITY

ALARM, CAMERA SYSTEM WIRING, WAPS, FIRE ALARM AND INTERCOM

WIRING AND DEVICES. MODULARS ARE TO BE PROVIDED WITH BOXES AND

PATHWAYS WITH PULLSTRINGS TO ACCESSIBLE CEILINGS.

OWNER'S CONTRACTOR IS RESPONSIBLE FOR CONNECTING ALL

ELECTRICAL SYSTEMS TO ALL BUILDINGS

VARIES BY MANUFACTURER

+/- 33' - 0" 5' - 0"

VARIES BY MANUFACTURER

+/- 64' - 0"

10' MIN.

10' - 8 1/2" 10' - 3 1/2"

V A

R

IE

S B

Y M

A N

U F

A C

T U

R E

R

3'

/2

21' - 0" TO EXISTING BUILDING

M

M

IT IS NOTED THAT THE PROPOSED 12 CLASSROOM BUILDING WOULD EXCEED THE OCCUPANT

LIMIT OF 300 OF A FIRE AREA BEFORE A SPRINKLER SYSTEM WOULD BE REQUIRED.

THE MODULAR LEASING COMPANY TO PROVIDE A 2 HOUR RATED FIRE BARRIER WITH TWO 90

MINUTE RATED DOORS, WHICH CREATES TWO FIRE AREAS WITH LESS THAN 300 OCCUPANTS

EACH AND WOULD NOT REQUIRE ANY SPRINKLER SYSTEM. SEE MODULAR LIFE SAFETY PLAN

(SHEET A005-P0) FOR MORE INFORMATION.

OWNER'S GENERAL CONTRACTOR WILL PROVIDE THE HOLD OPEN DEVICES AND CONNECT TO

THE FIRE ALARM SYSTEM.

ALL MODULARS ARE TO BE DELIVERED AND SET IN PLACE BY THE MODULAR

LEASING COMPANY. INCLUDE SKIRTING AND ANY OTHER ON SITE INSTALLS

FOR A FINISHED BUILDING.

OWNER'S CONTRACTOR WILL INSTALL ACCESS CONTROLS, SECURITY

ALARM, CAMERA SYSTEM WIRING, WAPS, FIRE ALARM AND INTERCOM

WIRING AND DEVICES. MODULARS ARE TO BE PROVIDED WITH BOXES AND

PATHWAYS WITH PULLSTRINGS TO ACCESSIBLE CEILINGS.

OWNER'S CONTRACTOR IS RESPONSIBLE FOR CONNECTING ALL

ELECTRICAL SYSTEMS AND PLUMBING CONNECTIONS TO ALL BUILDINGS

SEE SITE PLAN FOR NOTE ON FENCING

BY OTHERS/NOT IN SCOPE

UNCOVERED RAMP FOR EGRESS

M3

M4

M3 M4

M5

M1

M1

M1

M1

M1

M1

M1

M1

M1

M1

M1 n/an/a n/a

M5

M6 M6M6

A101-P0

1 TYP.

NOTE: ASSUMED DISTANCE ABOVE GRADE FOR EACH

MODULAR BUILDING. MODULAR LEASING COMPANY IS

RESPONSIBLE FOR MAKING ALL THREE STRUCTURES

LEVEL AT THE SAME ELEVATION.

SEE A101-P0 FOR DOOR SCHEDULE AND

TYPICAL CLASSROOM

+/- 11' - 7 3/4"

M1

A001-P0

BAND

GYM

M O

D U

LA

R

B U

IL

D

IN

G

S

IN

T

H

IS

S C

O P

E

6' chainlink fence indicated in red is to be removed by others for modular delivery. removal and replace for both modular delivery and modular removal is not the modular leasing company's responsibility.

suggested path for delivery of modular buildings.

this shall be coordinated with the general contractor on site prior to the start of any work

CAFETERIA

NOTE: this suggested route will interfere with car line, which occurs at the start and end of the school day. coordinate delivery with the owner such that these activities do not conflict.

STONE STREET

P E

A R

L S

T R

E E

T

(S

ID

E , N

O T

T O

S C

A

LE

R E

B E

L D

R

IV

E modular leasing company to advise if removing sections of fencing along gravel road is needed for delivery or removal, particularly for band and choral buildings. if this is necessary, it would be the responsibility of the owner's general contractor.

ADMIN

NORTH

gr av el r oa d/ ca r lin e sheet no.

sheet title msh job no.

issue date c 2026 msh architects llc revisions ea st k irk la nd s tr ee t c ov in gt on lo ui si an a ph on e:

.8

.0 em ai l:

st ud io m sh -a rc hi te ct s.

co m w w w

.m sh

-a rc hi te ct s.

co m

2535.1

09.04.2026

B o y e t J r.

H ig h S c h o o l, M

O D

U L A

R L

E A

S

IN

G P

L A

N S

R e b e l D r, S lid e ll, L

A

S T

P S

B P ro je c t

N o

T B

D

C U s e rs \R e b e c c a

\D o c u m e n ts

\2

S T

P S

B B o y e t J u n io r H ig h

S c h o o l R e n o v a ti o n s

C

U R

R E

N T rm b m s h .r v t

9/4/2026 2:27:46 PM

A100-P0

Overall Plans for Modulars to be Leased

3/32" = 1'-0"A100-P0

2 Leased Modulars Plan

1" = 80'-0"A100-P0

1 Site Plan for Modulars to be Leased

INDEX OF DRAWINGS

A100-P0 Overall Plans for Modulars to be Leased

OWNER PROVIDED SURVEY

A101-P0 Details & Schedules for Modulars to be Leased A005-P0 preliminary modular life safety plan

Electrical Modular Addition Scope

In addition to basic electrical requirements, provide the following:

• Overall for each modular building (classroom, band, and choral):

• Provide a minimum of (3) additional 120V/1P, 20A spare circuit breakers and a total of 14A (1,620W) spare capacity on each panelboard serving the (12) classrooms, the band building, and the choral building. This additional capacity shall accommodate added quadruplex receptacles and a smartboard duplex receptacle as required by STPSB IT department.

• Specific additional loads:

• Provide a minimum of (2) additional 120V/1P, 20A circuit breakers and a total of 6A (720W) additional spare capacity in (1) of the classroom panels. This additional capacity shall accommodate added quadruplex receptacles at the modular building IDF. Coordinate with owner to identify the classroom panel to be located closest to the existing IDF located in the gym.

BASE FLOOD ELEVATION INFORMATION

• See owner provided survey. It is noted that the Choral Building must have the finished floor elevation at 2' above the BFE of 14'. It is the design intent that all buildings are level and at the same elevation

• An elevation certificate for a finished floor elevation of 16' or greater must be provided during construction.

BUILDING B BUILDING C

BUILDING A - 12-CLASSROOMS, WITH RESTROOMS, INTERNAL HALLWWAY AND FIRE WALL

SD

.3'

DRAIN INLET

TOP = 15.37'

B.O.S.= 12.19'

DRAIN INLET

TOP = 15.55'

B.O.S.= 14.45'

DRAIN INLET

TOP = 15.64'

B.O.S.= 14.54'

.0'

.7'

.5'

DRAIN INLET

TOP = 13.71'

W INV= 11.66'

(S PIPE SETBACK)

(NE PIPE SETBACK)

14.3' 13.9'

.0

15.2' 15.0' 15.1'

DRAIN INLET

TOP = 15.37'

E INV= 11.97'

SW INV= 13.32'

N INV= 11.59'

DRAIN INLET

TOP = 14.97'

B.O.S.= 11.32'

DRAIN INLET

TOP = 15.02'

S INV= 11.97'

W INV= 11.92'

SW INV= 13.24'

DRAIN INLET

TOP = 15.67'

B.O.S.= 14.57'

DRAIN INLET

TOP = 13.90'

S INV= 12.50'

N INV= 12.50'

DRAIN INLET

TOP = 13.94'

W INV= 12.49'

N INV= 12.54'

DRAIN INLET

TOP = 13.65'

E INV= 12.45'

.4

.1 ' 14.7'

15.3'

DRAIN INLET

TOP = 13.49'

S INV= 11.79'

N INV= 11.84'

DRAIN INLET

TOP = 13.37'

S INV= 11.62'

N INV= 11.57'

DRAIN INLET

TOP = 13.34'

B.O.S.=11.14'

(PIPE SETBACK)

DRAIN INLET

TOP = 13.73'

S INV= 11.73'

N INV= 11.78'

(W PIPE SETBACK)

DRAIN INLET

TOP = 12.88'

B.O.S.= 11.83'

DRAIN INLET

TOP = 12.57'

E INV= 10.77'

W INV= 10.87'

DRAIN INLET

TOP = 12.53'

DRAIN INLET

TOP = 13.06'

E INV= 11.56'

W INV= 11.66'

DRAIN INLET

TOP = 12.88'

E INV= 11.36'

W INV= 11.34'

DRAIN INLET

TOP = 12.69'

S INV= 10.04'

E INV= 10.19'

NE INV= 10.24'

DRAIN INLET

TOP = 12.26'

W INV= 10.36'

DRAIN INLET

TOP = 14.70'

E INV= 11.90'

S INV= 11.95'

DRAIN INLET

TOP = 13.79'

B.O.S.= 10.61'

DRAIN INLET

TOP = 12.31'

N INV= 10.36'

S INV= 10.31'

DRAIN INLET

TOP = 12.96'

N INV= 10.64'

W INV= 10.63'

DRAIN INLET

TOP = 13.97'

NW INV= 12.77'

SW INV= 12.67'

S INV= 12.77'

DRAIN INLET

TOP = 12.87'

NE INV= 11.43'

SE INV= 11.47'

DRAIN INLET

TOP = 13.28'

E INV= 11.40'

SW INV= 11.46'

DRAIN INLET

TOP = 13.27'

E INV= 10.91'

W INV= 10.92'

15.7'

.6

.5

.5

.0

.4

.0

.6

.2

.8

.0

14.1'

14.1'

14.5'

14.3'

14.4'

14.2'

14.4'

14.5'13.9'

13.3'

13.6'13.8'13 .9

.8

.0

.1

.7

13.7'

.8

.6

.8

.1

.6

'14.3'15.1'15.6'

15.8' 14.9' 15.1'

15.3'

14.8'

14.8'

14.3'

14.0'

.9

.9

.2

.4

.8

.7

.4

.0

.0

.3

.3

.3

' 13.7' 14.3'

.4

.4

.6

DRAIN INLET

TOP = 12.96'

B.O.S.= 11.29'

(FULL)

DRAIN INLET

TOP = 12.83'

B.O.S.= 10.83'

(FULL)

DRAIN INLET

TOP = 12.58'

E INV= 10.06'

S INV= 10.28'

W INV= 9.95'

N INV= 10.06'

DRAIN INLET

TOP = 12.52'

E INV= 10.22'

W INV= 10.14'

11.7'

11.9'

11.8'

11.7'

11.8'

12.4'

12.0'

11.5'

11.5'

11.6'

12.1'

12.0'

12.9'

13.5'

13.7'

13.4'

13.1'12.8'

13.4'

13.8'

13.7'

13.9'

14.2'

13.5'

13.2'

13.1'

12.9'

12.9'

12.8'

.2

.6

.0

12.9'

13.0'

12.7'

12.1'13.1'

13.6'

13.6'

13.2'

13.2'

13.0'

13.0'

13.8'

14.5'

14.6'

14.5'

14.3'

13.6'

13.4'

13.3'

13.2'

12.7'13.2'

13.6'

13.5'

13.4'

13.9'

14.7'

14.5'

14.5'

14.4'

14.1'

.2

13.2' 13.2'

14.0'

14.7'

13.5'

.8

14.5'

12.0'

13.3'

13.5'

13.7'

13.8'

.9

12.3'

13.4'

13.2'

.4

13.6'

.6

.5

.3

13.4'13.3'

15.4'

15.6'

14.6'

13.8'

13.7'

13.7'

13.8'

13.5'

13.2'

13.4'

14.1'

14.6'

13.8'

13.3'

12.8'

12.4'12.5'

13.3'

13.6'

14.2'

14.4'

13.9'

13.1'

13.3'

13.6'

13.9'

13.6'

13.5'

13.6'

14.5'

14.9'

15.3'

14.9'

14.3'

13.9'

14.1'

13.9'

14.1'

13.8'

14.6'

15.6'

13.9'

14.1'

15.0'

14.5'

15.4'

15.1'

14.7'

13.4'

13.2'

13.2'

13.8'

13.7'

13.0'

14.2'

13.8'

14.1'

14.5'

14.2'

13.7'

13.7'

13.6'

13.9'

15.2'

15.0'

14.7'

14.2'

13.5'

14.1'

14.0'

13.9'

13.4'

12.9'

13.0'

13.8'

13.1'

13.4'

13.6'

.9

.2

14.1'

13.9'

13.9'

13.3'

12.9'

13.1'

13.4'

13.7'

13.0'

13.4'

13.6'

13.0'

13.6'

13.4'

.2

.0

.0

13.0'

12.8'

13.0'

13.6'

13.2'

13.4'

13.1'

13.3'

13.0'

13.6'

13.4'

13.3'

13.1'

12.9'

13.1'

13.4'

13.7'

.1

.1

13.0'

13.3'

12.9'

12.5'

14.1'

13.4'

12.5'

DRAIN INLET

TOP = 13.83'

B.O.S.=11.27'

14.9'

15.1'

15.2'

15.6'

.1

.1

14.8'

14.7'

14.7'

14.6'

15.0'

15.4' 15.8'

15.0'

15.1'

15.1'

15.3'15 .6

15.4'

15.3'15.1' 15.4' 15.8' 15.4'15

.6

15.8' 15.9' 15.9'

15.7' 15.9' 15.9'

15.6'15.9' 15.8'16.0'

16.0' 15.9'

15.9'

DRAIN INLET

TOP = 15.75'

W INV= 14.90'

DRAIN INLET

TOP = 15.79'

B.O.S.= 14.89'

16.0' 16.0'

16.1'16.1' 16.0'

15.7'

15.6'

15.7'

15.7'

16.2'

15.9'

15.7'

15.6'

15.2'

15.1'

14.9'

.6

.3

.1

.2

.4

16.0'

15.8'

15.9'

15.9'

15.8'

16.0'

15.4'

15.8'

15.5'

16.0'

14.6'

14.9'

14.4'14.2'

15.0' 14.6'

15.5'

15.7'

15.9'

16.0'

15.9'

16.0'

16.0'

15.9'15.7'

15.9'

DRAIN INLET

TOP = 15.73'

B.O.S.= 14.53'

DRAIN INLET

TOP = 15.67'

B.O.S.= 13.49'

DRAIN INLET

TOP = 15.74'

B.O.S.= 14.39'

DRAIN INLET

TOP = 15.50'

B.O.S.= 14.10'

DRAIN INLET

TOP = 15.27'

B.O.S.= 13.27'

DRAIN INLET

TOP = 15.53'

B.O.S.= 14.43'

14.5'

14.1'

14.6'

14.6'

15.8' 15.8'

15.3' 15.4'

15.1'

15.2' 15.2'

14.6'14.5'

14.8'

14.6'

.7

' DRAIN INLET

TOP = 14.44'

NE INV= 13.27'

14.2'

14.0'

.9

14.2'

14.0'

.9

.9

.1

14.5'

.5

.3

14.6'14.7'14.9'14.9'14.9'15.3'

14.7' 15.0' 14.7' 14.7'

14.6'15.1'15.2'15.5'14.7'

.4

14.5' 14.4' 14.2' 14.1' 13.9'

.9

14.6'15.4'15.1' 14.6'15.0'

14.7' 14.6' 14.7' 14.7' 14.7' 14.7' 14.6'

.5

13.4'13.8'14.2'14.1'14.3'14.6'14 .8

.8

.8

.7

.8

14.5'

.6

.7

DRAIN INLET

TOP = 14.24'

14.4' 14.5' 15.3' 14.7' 14.4'

15.8' 15.3' 15.1' 15.7'

15.4' 15.7'

16.0'

.5

.7

DRAIN INLET

TOP = 15.52'

E INV= 14.17'

DRAIN INLET

TOP = 15.60'

SE INV= 14.60'

15.9'

.6

.4

.1

.0

.0

.9

.0

.0

14.8'

15.3'

15.2'

.5

.3

.3

.9

.9

.4

.5

.1

.2

.8

.8

.1

.3

.1

15.8'

.8

15.2'

14.9'

15.1'

16.0' 16.0'

.9

14.7'

16.0'

DRAIN INLET

TOP = 12.93'

SW INV= 10.13'

SD

SD SD SD SD SD SD

SD

SD

SD

SD SD SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD SD

SD

SD

SD

SD SD SD SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD SD SD SD SD

SDSD

SD

5/8" IRON ROD FOUND

5/8" IRON ROD FOUND

1/2" IRON PIPE FOUND

TH

IS

D R

AW

IN

G A

N D

D

ES

IG

N

A R

E

TH

E

PR

O

PE

R

TY

O F

T H

EY

A

R E

SU

BM

IT

TE

D O

N T

H E

C O

N D

IT

IO

N

TH

AT

T

H

EY

A R

E N

O T

TO

B

E U

SE

D

R

EP

R

O D

U C

ED

, O

R C

O

PI

ED

, I

N W

H O

LE

O

R

IN

P

AR

T, O

R U

SE

D

F O

R

FU

R N

IS

H

IN

G

IN

FO

R M

AT

IO

N T

O O

TH

ER

S, W

IT

H

O U

T

TH

E

PR

IO

R

W R

IT

TE

N C

O N

SE

N

T O

F A

LL

C

O M

M O

N

LA

W R

IG

H

TS

O

F C

O

PY

R

IG

H T

AN

D

O

TH

ER

W

IS

E

AR

E

H

ER

EB

Y

SP

EC

IF

IC

AL

LY

R

ES

ER

VE

D

DATEJOHN E. BONNEAU

Registered Professional Land Surveyor Louisiana Registration No. 4423

08/04/2025

I do hereby certify that, as of the date set forth above that, I or others under my direct supervision, have made a careful survey of certain planimetric features relating to a portion of ground in Section 1, Township 9 South, Range 14 East; St. Tammany Parish, Louisiana.

E N

G I N

E E

R S

= WATER METER

LEGEND

= FIRE HYDRANT

= WATER VALVE

= SEWER CLEANOUT

= BOLLARD

= POWER POLE

= OVERHEAD POWER LINE

= FENCE

= FLOOD ZONE LINE

SD = DRAIN LINE

WM

= POWER BOX

= SIGN

= DRAIN INLET

= LIGHT POLE

= TELEPHONE PEDESTAL

= CONDUIT

= CABLE BOX

= SHUT OFF VALVE

= PINE TREE

= OAK TREE

= LIVE OAK

= CALLERY PEAR TREE

= CRAPE MYRTLE

= CYPRESS TREE

= FENCE POST

5'

(typ. width of classrooms)

+/- 30' - 0"

1' - 0"

(typ. width of classrooms on side with furr out)

+/- 29' - 0" eg re ss ib le o pe ra bl e w in do w w ith b lin ds m in im um p er cl as sr oo m

H V

A C

H V

A C

ELECTRICAL PANELS

cl as sr oo m d oo r, se e sc he du le

M1

NOTE: MARKER AND TACK BOARDS TO BE

PROVIDED BY THE MODULAR LEASING COMPANY

IN EACH CLASSROOM.

THIS APPLIES TO THE FULL SCOPE.

FURR OUT ONLY ON SIDE OF BUILDING WITH

HVAC AND ELEC. PANELS; OPP. SIDE DOES

NOT HAVE FURR OUT

NOTE: THE DESIGN INTENT IS FOR THE NET

SQUARE FOOTAGE OF THE CLASSROOMS TO BE

750 SF TYPICAL. EXACT LENGTH AND WIDTH OF

ROOM WILL VARY BY MANUFACTURER.

sheet no.

sheet title msh job no.

issue date c 2026 msh architects llc revisions ea st k irk la nd s tr ee t c ov in gt on lo ui si an a ph on e:

.8

.0 em ai l:

st ud io m sh -a rc hi te ct s.

co m w w w

.m sh

-a rc hi te ct s.

co m

2535.1

100% CDs for Owner Review

09.04.2026

B o y e t J r.

H ig h S c h o o l, I n fr a s tr u c tu re a n d

C o o rd in a ti o n f o r M o d u la rs

R e b e l D r, S lid e ll, L

A

S T

P S

B P ro je c t

N o

C U s e rs \R e b e c c a

\D o c u m e n ts

\2

S T

P S

B B o y e t J u n io r H ig h

S c h o o l R e n o v a ti o n s

C

U R

R E

N T rm b m s h .r v t

9/4/2026 9:17:43 AM

A101-P0

Details & Schedules for Modulars to be Leased

Leased Modular Door Schedule

Door Number Quantity

Door Frame

Fire Rating Hardware CommentsWidth Height Material Material

M1 12 3' - 0" 6' - 8" WOOD/GLASS METAL 20 min. 01 Narrow Lite (20 min) with bottom of glazing max 43" AFF

M2 2 3' - 0" 6' - 8" WOOD METAL 90 Minutes 02

M3 2 3' - 0" 6' - 8" WOOD METAL 20 min. 03

M4 2 3' - 0" 6' - 8" METAL METAL 20 min. 04

M5 2 6' - 0" 6' - 8" INSUL. METAL/GLASS METAL 05 Half lite with bottom of glazing max 43" AFF

M6 3 3' - 0" 6' - 8" INSUL. METAL/GLASS METAL 06 Half lite with bottom of glazing max 43" AFF

1/4" = 1'-0"A101-P0

1 typical example classroom

GENERAL NOTES: DOOR SIZES ARE RECOMMENDATIONS, IT IS NOTED 7'-0" HEIGHT IS ALSO ACCEPTABLE. ALL DOORS TO COMPLY WITH APPLICABLE CODES.

HARDWARE SETS

HW 1:

3 HINGES

1 CLOSER

F07 STOREROOM LOCKSET

MUTES

STOP

HW 2:

3 HINGES

1 CLOSER

PANIC BARS ON PUSH/LEVERSET ON PULL WITH LATCHING (FREE NON-LOCKING FROM BOTH DIRECTIONS)

SMOKE GASKETING IF REQUIRED FOR FIRE RATING

*NOTE THAT HOLD OPEN DEVICES ARE TO BE INSTALLED BY OTHERS AND CONNECTED TO FIRE ALARM SYSTEM.

HW 3:

3 HINGES

1 CLOSER

PASSAGE LOCKSET WITH LATCHING

MOP PLATES

MUTES

STOPS

HW 4:

3 HINGES

1 CLOSER

F07 STOREROOM LOCKSET

MOP PLATES

MUTES

STOPS

HW 5:

6 HINGES

2 CLOSER

WEATHERSTRIPPING

THRESHOLD

TWO (2) EXIT DEVICES/ FUNCTION CODE 09/ LESS DOGGING

ASTRAGAL

REMOVABLE MULLION

HW 6:

3 HINGES

1 CLOSER

WEATHERSTRIPPING

THRESHOLD

MORTISE LOCKSET F07 STOREROOM (LATCHBOLT/DEADBOLT)

ELECTRIC STRIKE, BASIS OF DESIGN = 1600 SERIES (POE) BY MANUF. HES, an Assa Abloy Group company;[HES 5000 (interior)/ HES 1600 (exterior)]:

www.assaabloydss.com/#sle.

*NOTE THAT IT IS THE DESIGN INTENT THAT THESE DOORS WILL RECEIVE ACCESS CONTROLS BY OWNER. SEE ELECTRICAL FOR DATA WIRING, ALL OTHER ITEMS

FOR ACCESS CONTROLS ARE INSTALLED BY OWNER.

ADDITIONAL PRODUCT INFORMATION - Electric Strikes: Comply with BHMA A156.31, Grade 1.

Provide UL (DIR) listed burglary-resistant electric strike; style to suit locks.

Provide non-handed 24 VDC electric strike suitable for door frame material and scheduled lock configuration.

Provide field selectable Fail Safe/Fail Secure modes.

Strikes shall be compatible with Owner's card access system. See Hardware Schedule for Basis of Design (BOD) strikes.

M O

D U

LA

R

L E

A S

IN

G

P

LA

N S

T B

D issue date revisions

09.04.2026

B o y e t J r.

H ig h S c h o o l, M

O D

U L A

R L

E A

S

IN

G P

L A

N S

R e b e l D r, S lid e ll, L

A

S T

P S

B P ro je c t

N o

T B

D

F E

C

F E

C

WH

F E

C

F E

C

FEC

TRAVEL DISTANCE: 126' - 5"

TRAVEL DISTANCE: 131' - 5"

C.P.E.T.: 46' - 3"

FIRE AREA 2

FIRE AREA 1

30" X 48" EXTERIOR

AREA FOR ASSISTED

RESCUE

GENERAL CONTRACTOR IS REQUIRED TO PROVIDE

ADA COMPLIANT LANDINGS AND THRESHOLDS AT ALL

MODULAR CLASSROOM DOORS EXISTING PAVING. GENERAL

This is the start of the file's text. The full file is on GovTribe.