These are specification documents for replacement luff hoist wire rope for a Portal Crane, with separate specifications provided for port and starboard configurations.
The wire rope specifications require ASTM A1023/A1023M-21 compliant 6 × 36 classification wire rope manufactured from extra improved plow steel (Grade 1960) or extra-extra improved plow steel (Grade 2160). The rope must be pre-formed, non-rotation resistant, with bright uncoated finish, right regular lay construction, and nominal diameter of 1-3/4 inches (±0%/+5%). Both port and starboard ropes must measure at least 530 feet in length (±0%/+1%), with minimum breaking strength of 263,644 pounds, bend radius ratio D/d of 24 or less, and be sourced from a single continuous reel without splices. Each rope must include two distinct end connections: an open spelter socket (Crosby S-416, P/N 1039842) fabricated per Naval Ships' Technical Manual S9086-UU-STM-010 Chapter 613 Rev. 5 using either poured zinc or resin, and a welded Link Becket per the Wire Rope User's Manual fifth edition. Wire rope must be shipped on metal spools with an additional empty metal spool provided for inspection purposes.
Inspection by Code 700 Personnel at Portsmouth Naval Shipyard covers entire rope length for defects including kinks, bird-caging, flattening, broken wires, corrosion, heat damage, and wavy rope conditions. End connections are inspected for broken wires, kinking, stretching, twisting, undue looseness, and excessive wear. Pre-delivery testing requires breaking strength verification per ASTM A931-18 (must exceed 263,644 pounds) and pull-testing of socket end connections to 79,750 pounds. Contractor submittals must include certified documentation with traceability to manufacturer and reel, confirming all material specifications, actual breaking strength, and Charpy V-notch test reports for each open spelter socket. Acceptance occurs at destination only after government approval of all data, successful final inspection, and correction of any deficient items, with uncorrected deficiencies carried as contractor warranty obligations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 27Q6006 RFQ Required.docx | DOCX document | |
| Clauses - Full Text Provisions and Clauses 11-4-2026.docx | DOCX document | |
| NSTM S9086-UU-STM-010 Chapter 613 Rev 5 1JUN18 - Wire and Fiber Rope and Rigging.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LUFF HOIST (PORT) WIRE ROPE SPECIFICATIONS
1. SCOPE OF WORK:
Provide replacement luff hoist (port) wire rope for Portal Crane.
2. SPECIFICATIONS:
2.1 WIRE ROPE SHALL:
Be ASTM A1023/A1023M-21 compliant 6 × 36 classification wire rope.
Not be rotation resistant.
Be extra improved plow steel (EIPS/XIPS/Grade 1960) or extra-extra improved plow steel (EEIPS/XXIPS/Grade 2160) wire rope.
Be pre-formed wire rope.
Have bright (uncoated), non-galvanized surface finish.
Be of right regular lay (RRL) lay type and lay direction.
Have an independent wire rope core (IWRC), wire strand core, or steel core.
Permanently lubed and plastic filled ropes are permissible.
Be 1-3/4” (-0%/+5%) nominal diameter (ASTM A1023/A1023M-21).
Be at least 530 ft. (-0%/+1%) (within 1’ of starboard luff wire rope length) in length.
Have a minimum breaking strength of at least 263,644 lbs.
Have a minimum bend radius ratio D/d less than or equal to 24.
Be in one continuous spool, all taken from the same reel; the use of splices to permanently connect different reels of wire rope is prohibited.
The spool the wire rope to be shipped with will be of metal construction only To facilitate the inspection of the wire rope, be shipped with an additional empty metal spool equivalent in size to the spool containing the wire rope.
Have two distinct types of end connections, one at each end of the wire rope.
o The first end connection shall be an open spelter socket, Crosby S-416, P/N: 1039842, unpainted.
On location or prior to putting on reel, it shall be either poured (i.e. molten zinc) or with resin, into a steel socket.
Poured spelter socket end connections shall be fabricated in accordance with Naval Ships’ Technical Manual (NSTM) S9086-UU-STM-010 Chapter 613 Rev. 5, sections 1.11.2 through 1.11.2.3(m).
Resin socketing material must meet NSTM S9086-UU-STM-010 Chapter 613 Rev. 5, sections 1.11.3 through 1.11.3(h)(4), and resin end connections shall be fabricated in accordance with the resin OEM’s instructions.
o The other end connection shall be a welded Link Becket per the latest edition of the Wire Rope User’s Manual fifth edition.
3. INSPECTION:
The two areas that require inspection are the wire rope and the end connections. The inspection criteria for these two areas are included below:
3.1 WIRE ROPE:
The wire rope shall be inspected by government personnel (specifically Code 700 Personnel located at Portsmouth Naval Shipyard) prior to acceptance by the government. This inspection shall be performed at destination by the receiving activity. The entire length of the wire rope shall be inspected using additional equipment as necessary for access.
Inspection criteria are as follows, the wire rope shall not:
Have any kinked, bird-caged, dog-legged, or crushed sections of rope where the core is missing or protrudes through or between strands.
Have any flattened sections where the diameter across the flat is less than 5/6 of the nominal diameter.
Have six or more broken wires across all strands in a length equal to six times the nominal rope diameter.
Have twelve or more broken wires in a length equal to thirty times the nominal rope diameter.
Have two or more outer wires broken at the point of contact with the core of the rope that has worked its way out of the rope structure and protrudes or loops out from the rope structure (valley break type).
Have two or more broken wires within a length equal to 30 times the nominal rope diameter from the end termination.
Have a measured loss from reference diameter greater than three and a half percent of the nominal diameter. New wire rope reference diameter is to be obtained from reel certification documentation or by direct measurement.
Have any high or low strands where the height or depth exceeds one-half the strand diameter.
Have any corrosion such that significant pitting occurs on the surfaces of outside wires and obvious signs of internal corrosion such as magnetic debris coming from the valleys. Minor surface roughness on outside wires is acceptable provided no significant pitting occurs and the rope is not corroded internally. Significant pitting is defined as pitting that cannot be removed by abrasive removal of less than 1/3 of the diameter of individual outside wires.
Have any heat damage evidence from any cause.
Have any wavy rope (where the longitudinal axis of the wire rope takes the shape of a helix instead of a line) when the diameter of the envelope of the wave is greater than 110% of the diameter of the nominal diameter of the wire rope.
Have any accumulation of defects which, in the judgment of the government inspector, creates an unsafe condition.
3.2 END CONNECTIONS:
The end connections shall be inspected for excessive wear, broken wires, stretching, kinking, twisting, or undue looseness of, at, or in end connections. Undue looseness is defined as abnormal looseness due to wear, distortion, slippage, etc., of individual components of end fittings or between end fittings and other mating components. Undue looseness in poured sockets is defined as looseness or evidence of slippage of wires in the potting material, evidence of deterioration (crushing or other significant deformation) of the potting material, looseness of wire rope strands or wires adjacent to the poured socket, or any looseness resulting from cracks or other defects in the socket.
Inspection criteria are as follows, the end connections shall not:
Have any broken wires of, at or in the end connections.
Have any kinking of, at or in the end connections.
Have any stretching of, at or in the end connections.
Have any twisting of, at or in the end connections.
Have any undue looseness of, at or in the end connections.
Have any excessive wear of, at or in the end connections.
3.3 PRE-DELIVERY:
Open spelter socket shall be:
Inspect/witness the socket pour for compliance with o Poured spelter socket end connections shall be fabricated in accordance with Naval Ships’
Technical Manual (NSTM) S9086-UU-STM-010 Chapter 613 Rev. 5, sections 1.11.2 through 1.11.2.3(m). or o Resin socketing material must meet NSTM S9086-UU-STM-010 Chapter 613 Rev. 5, sections 1.11.3 through 1.11.3(h)(4), and resin end connections shall be fabricated in accordance with the resin OEM’s instructions.
Inspected to ensure after the pour is complete, there is no bend in the socket to wire connection
4. TESTING:
There shall be testing evolutions that occur prior to delivery; they are listed below, and their results shall be submitted to the government for approval.
4.1. PRE-DELIVERY:
The actual breaking strength shall be determined using the methodology in ASTM A931-18, based on a sample taken from the same reel of wire rope. The actual breaking strength shall exceed the specified minimum breaking strength of 263,644 lbs.
The wire rope socket end connection shall be submitted to a pull-test of 79,750 lbs.
5. ACCEPTANCE:
Acceptance of the supplies or services to be furnished hereunder shall be made at destination by the receiving activity. Code 700 located at Portsmouth Naval Shipyard shall provide inspection personnel to accomplish the wire rope inspection. Following completion of government inspection, final government acceptance of the wire rope shall take place only after the following conditions are met:
5.1. CONDITIONS:
5.1.a. Contractor receives Government approval for all data items and submittals.
5.1.b. The wire rope passes a final inspection by the Government, per the previously listed inspection criteria.
5.1.c. All deficient items have been corrected, or methods of resolution have been determined.
Deficient items not corrected prior to the Government’s acceptance shall be carried as warranty items, which will be corrected by the Contractor.
6. SUBMITTALS:
The contractor shall submit to the Contracting Officer all items of technical documentation listed hereinafter. The contractor shall ensure that all submittals are entirely legible and suitable for reproduction. Compliance with the requirements of this specification will be determined by a review of the submittals by the government and acceptance inspection/testing.
6.1. REQUIREMENTS:
6.1.a. The contractor shall submit certification with positive traceability to the wire rope manufacturer and wire rope reel that provides the following documentation:
The diameter of the wire rope.
The length of the wire rope.
The minimum breaking strength of the wire rope.
The actual breaking strength of the wire rope.
That the wire rope is fabricated to ASTM A1023/A1023M-21 standards.
That the wire rope is fabricated with extra improved or extra-extra improved plow steel.
That the wire rope is pre-formed.
That the wire rope is bright (uncoated) and non-galvanized.
That the wire rope is right regular lay (RRL).
That the wire rope has an independent wire rope, wire strand or steel core.
6.1.b. The contractor shall submit documentation that the wire rope’s socket end connection is spelter or resin and has been satisfactorily pull-tested to 79,750 lbs.
6.1.c The contractor shall submit a Charpy V-notch test report for each supplied Open Spelter Socket.
LUFF HOIST (STARBOARD) WIRE ROPE SPECIFICATIONS
1. SCOPE OF WORK:
Provide replacement luff hoist (port) wire rope for Portal Crane.
2. SPECIFICATIONS:
2.1 WIRE ROPE SHALL:
Be ASTM A1023/A1023M-21 compliant 6 × 36 classification wire rope.
Not be rotation resistant.
Be extra improved plow steel (EIPS/XIPS/Grade 1960) or extra-extra improved plow steel (EEIPS/XXIPS/Grade 2160) wire rope.
Be pre-formed wire rope.
Have bright (uncoated), non-galvanized surface finish.
Be of right regular lay (LRL) lay type and lay direction.
Have an independent wire rope core (IWRC), wire strand core, or steel core.
Permanently lubed and plastic filled ropes are permissible.
Be 1-3/4” (-0%/+5%) nominal diameter (ASTM A1023/A1023M-21).
Be at least 530 ft. (-0%/+1%) (within 1’ of port luff wire rope length) in length.
Have a minimum breaking strength of at least 263,644 lbs.
Have a minimum bend radius ratio D/d less than or equal to 24.
Be in one continuous spool, all taken from the same reel; the use of splices to permanently connect different reels of wire rope is prohibited.
The spool the wire rope to be shipped with will be of metal construction only To facilitate the inspection of the wire rope, be shipped with an additional empty metal spool equivalent in size to the spool containing the wire rope.
Have two distinct types of end connections, one at each end of the wire rope.
o The first end connection shall be an open spelter socket, Crosby S-416, P/N: 1039842, unpainted.
On location or prior to putting on reel, it shall be either poured (i.e. molten zinc) or with resin, into a steel socket.
Poured spelter socket end connections shall be fabricated in accordance with Naval Ships’ Technical Manual (NSTM) S9086-UU-STM-010 Chapter 613 Rev. 5, sections 1.11.2 through 1.11.2.3(m).
Resin socketing material must meet NSTM S9086-UU-STM-010 Chapter 613 Rev. 5, sections 1.11.3 through 1.11.3(h)(4), and resin end connections shall be fabricated in accordance with the resin OEM’s instructions.
o The other end connection shall be a welded Link Becket per the latest edition of the Wire Rope User’s Manual fifth edition.
3. INSPECTION:
The two areas that require inspection are the wire rope and the end connections. The inspection criteria for these two areas are included below:
3.1 WIRE ROPE:
The wire rope shall be inspected by government personnel (specifically Code 700 Personnel located at Portsmouth Naval Shipyard) prior to acceptance by the government. This inspection shall be performed at destination by the receiving activity. The entire length of the wire rope shall be inspected using additional equipment as necessary for access.
Inspection criteria are as follows, the wire rope shall not:
Have any kinked, bird-caged, dog-legged, or crushed sections of rope where the core is missing or protrudes through or between strands.
Have any flattened sections where the diameter across the flat is less than 5/6 of the nominal diameter.
Have six or more broken wires across all strands in a length equal to six times the nominal rope diameter.
Have twelve or more broken wires in a length equal to thirty times the nominal rope diameter.
Have two or more outer wires broken at the point of contact with the core of the rope that has worked its way out of the rope structure and protrudes or loops out from the rope structure (valley break type).
Have two or more broken wires within a length equal to 30 times the nominal rope diameter from the end termination.
Have a measured loss from reference diameter greater than three and a half percent of the nominal diameter. New wire rope reference diameter is to be obtained from reel certification documentation or by direct measurement.
Have any high or low strands where the height or depth exceeds one-half the strand diameter.
Have any corrosion such that significant pitting occurs on the surfaces of outside wires and obvious signs of internal corrosion such as magnetic debris coming from the valleys. Minor surface roughness on outside wires is acceptable provided no significant pitting occurs and the rope is not corroded internally. Significant pitting is defined as pitting that cannot be removed by abrasive removal of less than 1/3 of the diameter of individual outside wires.
Have any heat damage evidence from any cause.
Have any wavy rope (where the longitudinal axis of the wire rope takes the shape of a helix instead of a line) when the diameter of the envelope of the wave is greater than 110% of the diameter of the nominal diameter of the wire rope.
Have any accumulation of defects which, in the judgment of the government inspector, creates an unsafe condition.
3.2 END CONNECTIONS:
The end connections shall be inspected for excessive wear, broken wires, stretching, kinking, twisting, or undue looseness of, at, or in end connections. Undue looseness is defined as abnormal looseness due to wear, distortion, slippage, etc., of individual components of end fittings or between end fittings and other mating components. Undue looseness in poured sockets is defined as looseness or evidence of slippage of wires in the potting material, evidence of deterioration (crushing or other significant deformation) of the potting material, looseness of wire rope strands or wires adjacent to the poured socket, or any looseness resulting from cracks or other defects in the socket.
Inspection criteria are as follows, the end connections shall not:
Have any broken wires of, at or in the end connections.
Have any kinking of, at or in the end connections.
Have any stretching of, at or in the end connections.
Have any twisting of, at or in the end connections.
Have any undue looseness of, at or in the end connections.
Have any excessive wear of, at or in the end connections.
3.3 PRE-DELIVERY:
Open spelter socket shall be:
Inspect/witness the socket pour for compliance with o Poured spelter socket end connections shall be fabricated in accordance with Naval Ships’
Technical Manual (NSTM) S9086-UU-STM-010 Chapter 613 Rev. 5, sections 1.11.2 through 1.11.2.3(m). or o Resin socketing material must meet NSTM S9086-UU-STM-010 Chapter 613 Rev. 5, sections 1.11.3 through 1.11.3(h)(4), and resin end connections shall be fabricated in accordance with the resin OEM’s instructions.
Inspected to ensure after the pour is complete, there is no bend in the socket to wire connection
4. TESTING:
There shall be testing evolutions that occur prior to delivery; they are listed below, and their results shall be submitted to the government for approval.
4.1. PRE-DELIVERY:
The actual breaking strength shall be determined using the methodology in ASTM A931-18, based on a sample taken from the same reel of wire rope. The actual breaking strength shall exceed the specified minimum breaking strength of 263,644 lbs.
The wire rope socket end connection shall be submitted to a pull-test of 79,750 lbs.
5. ACCEPTANCE:
Acceptance of the supplies or services to be furnished hereunder shall be made at destination by the receiving activity. Code 700 located at Portsmouth Naval Shipyard shall provide inspection personnel to accomplish the wire rope inspection. Following completion of government inspection, final government acceptance of the wire rope shall take place only after the following conditions are met:
5.1. CONDITIONS:
5.1.a. Contractor receives Government approval for all data items and submittals.
5.1.b. The wire rope passes a final inspection by the Government, per the previously listed inspection criteria.
5.1.c. All deficient items have been corrected, or methods of resolution have been determined.
Deficient items not corrected prior to the Government’s acceptance shall be carried as warranty items, which will be corrected by the Contractor.
6. SUBMITTALS:
The contractor shall submit to the Contracting Officer all items of technical documentation listed hereinafter. The contractor shall ensure that all submittals are entirely legible and suitable for reproduction. Compliance with the requirements of this specification will be determined by a review of the submittals by the government and acceptance inspection/testing.
6.1. REQUIREMENTS:
6.1.a. The contractor shall submit certification with positive traceability to the wire rope manufacturer and wire rope reel that provides the following documentation:
The diameter of the wire rope.
The length of the wire rope.
The minimum breaking strength of the wire rope.
The actual breaking strength of the wire rope.
That the wire rope is fabricated to ASTM A1023/A1023M-21 standards.
That the wire rope is fabricated with extra improved or extra-extra improved plow steel.
That the wire rope is pre-formed.
That the wire rope is bright (uncoated) and non-galvanized.
That the wire rope is right regular lay (RRL).
That the wire rope has an independent wire rope, wire strand or steel core.
6.1.b. The contractor shall submit documentation that the wire rope’s socket end connection is spelter or resin and has been satisfactorily pull-tested to 79,750 lbs.
6.1.c The contractor shall submit a Charpy V-notch test report for each supplied Open Spelter Socket.