This is a Contract Data Requirements List (CDRL) for plain studs comprising five data items to be delivered by the contractor to Portsmouth Naval Shipyard. The CDRL, prepared by Johnathan Farrington on 07/22/2026 and approved by Jason Laflamme on 10/29/2026, specifies inspection, testing, and certification documentation requirements for material shipments.
The five required data items are: (1) B001—Inspection and Test Plan covering inspection system procedures (DI-QCIC-81110); (2) B002—Certification data for special emphasis materials addressing chemical and mechanical properties (DI-MISC-81020); (3) B003—Certification/data report for special emphasis materials with certificate of conformance (DI-MISC-80678); (4) B004—Procedures and test for non-destructive testing (NDT) liquid penetrant inspection procedure approval (UDI-T-23732B), required prior to any penetrant testing and submitted to PNS Code 135T for review; and (5) B005—Certification/data report for all test certifications of NDT procedures including liquid penetrant inspection with acceptance (DI-MISC-80678). All data items require DD 250 documentation and are submitted once per shipment. Certification data must be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each material shipment, with each data item submitted under a separate shipment number. Payment and submission reference FAR clauses 252.232-7006, 252.232-7003, or 52.232-36. No material may be shipped prior to receipt of acceptance for items B004 and B005.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SPMYM327Q4007 LEVEL 1 Studs 6274425-2.pdf | ||
| Attachment 1 - TDP PNTDP0169 VER 001.pdf | ||
| Exhibit A - SPMYM327Q4007.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT DATA REQUIREMENTS LIST
Form Approved
0MB No. 0 70 4-0188
(1 Data Item)
A. CONTRACT LINE ITEM NO. B. EXHIBIT C.CATEGORY
TDP
D. SYSTEM/ITEM E. CONTRACT/PR NO. F. CONTRACTOR
STUD,PLAIN
. 2. TITLE OF DATA ITEM 3. SUBTIT LE 1. DATA ITEM NO
B001 INSPECTION AND TEST PLAN INSPECTION SYSTEM PROCEDURES
4. AUTHORITY (Data Acqlsltlon Document No.) 5. CONTRACT REFERENCE!
DI-QCIC-81110 ( SE) TDP, PARA 3.12.3
7. DD 250REQ 9. DIST STATEMENT 10. FREQUENCY 12. DATE OF FIRST SUBMISSION
LT REQUIRED ONE/ R N/A
8.APP CODE 11.AS OF DATE 13. DATE OF SUBSEQUENT
N/A 0 SUBMISSION
N/A
16.REMARKS
Paragraph 10 .4 of DI-QCIC-81110 does not apply.
For payment & submission of data refer to clauses 252.232-7006 and 252.232-700 3 or 52.232-36. Certification data shall be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material. Each data item submitted by vendor must be submitted under separate shipment number.
G. PREPARED BY
Johnathan Farrinaton
DD Form 1423-1, JUN 90
SIN 0102-LF -010-5600
. DATE I. APPROVED BY
07/22/2026 Jason Laflamme
6. REQUIRING OFFICE
CODE245
14. DISTRIBUTION
a. ADDRESSEE Draft
Code 1 36.2 0
15. Total 0
Page 1 of 5 Page(s)
b. COPIES
Final
Reg Repro
1 0
1 0
J.DATE
10 /29/26
0MB No. 0704-0188
(1 Data Item)
A. CONTRACT LINE ITEM NO. B. EXHIBIT C.CATEGORY
TDP
D. SYSTEM/ITEM E. CONTRACT/PR NO. F. CONTRACTOR
STUD,PLAIN
. 2. TITLE OF DATA ITEM 3. SUBTIT LE 1. DATA ITEM NO
B002 CERT DATA FOR SPECIAL EMPHASIS MATL CHEMICAL AND MECHANICAL
4. AUTHORITY (Data Acqlsltlon Document No.) 5. CONTRACT REFERENCE!
DI-MISC-81020 (DD) TDP: PARA 3.18
7. DD 250REQ 9. DIST STATEMENT 10. FREQUENCY 12. DATE OF FIRST SUBMISSION
SD REQUIRED ONE/R N/A
D
8.APP CODE 11.AS OF DATE 13. DATE OF SUBSEQUENT
N/A 0 SUBMISSION
N/A
16.REMARKS
For payment & submission of data refer to clauses 252.232-7006 and 252.232-7003 or 52.232-36. Certification data shall be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material.
Each data item submitted by vendor must be submitted under separate shipment number.
G. PREPARED BY
Johnathan Farrington
DD Form 1423-1, JUN 90
SIN 0102-LF -010-5600
H.DATE I. APPROVED BY
07/22/2026 Jason Laflamme
6. REQUIRING OFFICE
PURCHASING ACTIVITY
14. DISTRIBUTION
a. ADDRESSEE Draft
CODE 133.2 0
15. Total 0
Page 2 of 5 Page(s)
b. COPIES
Final
Reg Repro
1 0
1 0
10/29/26
0MB No. 0704-0188
(1 Data Item)
A. CONTRACT LINE ITEM NO. B. EXHIBIT C.CATEGORY
TDP
D. SYSTEM/ITEM E. CONTRACT/PR NO. F. CONTRACTOR
STUD,PLAIN
. 2. TITLE OF DATA ITEM 3. SUBTIT LE 1. DATA ITEM NO
B003 CERTIFICATION/DATA REPORT SPECIAL EMPHASIS C OF C
4. AUTHORITY (Data Acqlsltlon Document No.) 5. CONTRACT REFERENCE
DI-MISC-80678 (CCDD) TDP: PARA 3.24
7. DD 250REQ 9. DIST STATEMENT 10. FREQUENCY 12. DATE OF FIRST SUBMISSION
SD REQUIRED ONE/R N/A
D
8.APP CODE 11.AS OF DATE 13. DATE OF SUBSEQUENT
N/A 0 SUBMISSION
N/A
16.REMARKS
Block 4 - Paragraphs 10.2.1, 10.2.2, 10.2.3, 10.3, and 10.4 of DI-MISC-80678 do not apply.
For payment & submission of data refer to dauses 252.232-7006 and 252.232-7003 or 52.232-36. Certification data shall be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material.
Each data item submitted by vendor must be submitted under separate shipment number.
G. PREPARED BY
Johnathan Farrington
DD Form 1423-1, JUN 90
SIN 0102-LF -010-5600
H.DATE I. APPROVED BY
07/22/2026 Jason Laflamme
6. REQUIRING OFFICE
PURCHASING ACTIVITY
14. DISTRIBUTION
a. ADDRESSEE Draft
CODE 133.2 0
15. Total 0
Page 3 of 5 Page(s)
b. COPIES
Final
Reg Repro
1 0
1 0
0MB No. 0704-0188
(1 Data Item)
A. CONTRACT LINE ITEM NO. B. EXHIBIT C.CATEGORY
TDP
D. SYSTEM/ITEM E. CONTRACT/PR NO. F. CONTRACTOR
STUD,PLAIN
. 2. TITLE OF DATA ITEM 3. SUBTIT LE 1. DATA ITEM NO
B004 PROCEDURES, TEST NDT PT PROCEDURE APPROVAL
4. AUTHORITY (Data Acqlsltlon Document No.) 5. CONTRACT REFERENCE
UDI-T-23732B TDP: PARA 3.10
7. DD 250REQ 9. DIST STATEMENT 10. FREQUENCY 12. DATE OF FIRST SUBMISSION
SD REQUIRED ONE/R PRIOR TO ANY PT
D
8.APP CODE 11.AS OF DATE 13. DATE OF SUBSEQUENT
N/A 0 SUBMISSION
ASREQ
16.REMARKS
Block 4 - Paragraph 10.1 of UDI-T-23732B does not apply.
Non-Destructive Test Inspection Procedure. Liquid Penetrant Inspection IAWT9074-AS-GIB-010/271, Sampling per MIL-DTL-1222. Acceptance shall be per MIL-DTL-1222 and SAE Jl23.
The Vendor shall submit their PT inspection procedure prior to inspection to PNS Code 135T for review.
For payment & submission of data refer to clauses 252.232-7006 and 252.232-7003 or 52.232-36.
Certification data shall be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material. Each data item submitted by vendor must be submitted under separate shipment number. No material is to be shipped prior to the receipt of Acceptance.
G. PREPARED BY
Tohnathen Farrinuton
DD Form 1423-1, JUN 90
SIN 0102-LF -010-5600
H.DATE
07/22/2026
I. APPROVED BY
Jason Laflamme
6. REQUIRING OFFICE
CODE 245
14. DISTRIBUTION
a. ADDRESSEE Draft
135T 0
15. Total 0
Page 4 of 5 Page(s)
b. COPIES
Final
Reg Repro
1 0
1 0
J. DATE
0MB No. 0704-0188
(1 Data Item)
A. CONTRACT LINE ITEM NO. B. EXHIBIT C.CATEGORY
TDP
D. SYSTEM/ITEM E. CONTRACT/PR NO. F. CONTRACTOR
STUD,PLAIN
. 2. TITLE OF DATA ITEM 3. SUBTIT LE 1. DATA ITEM NO
BDOS CERTIFICATION/DATA REPORT TEST CERTIFICATIONS
4. AUTHORITY (Data Acqlsltlon Document No.) 5. CONTRACT REFERENCE
DI-MISC-80678 (DD) TOP: PARA 3.11
7. DD 250REQ 9. DIST STATEMENT 10. FREQUENCY 12. DATE OF FIRST SUBMISSION
SD REQUIRED ONE/R N/A
D
8.APP CODE 11.AS OF DATE 13. DATE OF SUBSEQUENT
N/A 0 SUBMISSION
N/A
16.REMARKS
Block 4 - Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 of DI-MISC-80678 do not apply.
All Test Certifications of NDT Procedures:
Liquid Penetrant Inspection with acceptance.
For payment & submission of data refer to dauses 252.232-7006 and 252.232-7003 or 52.232-36. Certification data shall be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material.
Each data item submitted by vendor must be submitted under separate shipment number. No material is to be shipped prior to the receipt of Acceptance.
G. PREPARED BY
Tohnathen Farrinlrton
DD Form 1423-1, JUN 90
SIN 0102-LF -010-5600
H.DATE I. APPROVED BY
07/22/2026 Jason Laflamme
6. REQUIRING OFFICE
CODE 245
14. DISTRIBUTION
a. ADDRESSEE Draft
133.2 0
15. Total 0
Page 5 of 5 Page(s)
b. COPIES
Final
Reg Repro
1 0
1 0
File details come from the government source that posted it. Updated .