Approved Deviations.pdf
PDF 24 KB Posted
- Attached to
- VLS RUGGEDIZED DESIGN SWITCHES
- Solicitation number
- SPMYM326Q6068
About this file
This is a drawing change notice document for engineering modifications to PC 3 (Housing Assembly) on Sheet 3 of drawing 6557926D. The document specifies ten discrete changes to dimensional tolerances, datum references, and geometric control callouts affecting the receptacle assembly.
The modifications include: deletion of a 1.90 reference dimension in Zone F6; updating the 1.25 dimension to 0.756 +/- 0.030 with measurement point relocation in Zone F6; removal of Datum C from True Position callouts for 0.0623/0.0625 holes in Zone F3; deletion of True Position tolerances to multiple datums for receptacle threads in Zone E3; replacement of 2x 1.90 dimensions with 2x 1.406 +/- 0.030 with measurement point adjustment in Zone B5; deletion of 0.020 parallelism tolerance to Datum C in Zone B5; removal of True Position tolerances in Zone A5; deletion of basic dimensions 1.125 in Zone A4 and 1.625 in Zone B4; and deletion of Datum C reference in Zone B3. These changes simplify the geometric control framework and adjust dimensional requirements for the housing assembly component.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Clauses - Full Text Provisions and Clauses 260210.docx | DOCX document | |
| 26Q6068 RFQ Required.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
All changes are to PC 3 (Housing Assembly) on SH 3 of 6557926D
1. Zone F6: Delete (1.90) Reference dimension
2. Zone F6: Update 1.25 dimension to 0.756 +/- 0.030 and move the bottom measurement point for the dimension upward from the back of receptacle threads to the step in the receptacle body
3. Zone F3: Delete Datum C from True Position callout for the 0.0623/0.0625 holes
4. Zone E3: Delete True Position of 0.030 to Datums A/B/D for the receptacle threads
5. Zone B5: Replace 2x 1.90 dimension with 2x 1.406 +/- 0.030 and move top measurement point for the dimension downward from back of receptacle threads (Datum C) to the step in the receptacle body (located between current Datum C and the weld between the receptacle and the frame).
6. Zone B5: Delete 0.020 parallelism to Datum C
7. Zone A5: Delete True Position of 0.060 to Datum D/C/E and 0.005 to Datum D
8. Zone A4: Delete 1.125 basic dimension
9. Zone B4: Delete 1.625 basic dimension
10. Zone B3: Delete Datum C
File details come from the government source that posted it. Updated .