SPMYM324Q2016 Exhibits.pdf
PDF 624 KB Posted
- Solicitation number
- SPMYM324Q2016
About this file
This document contains multiple Contract Data Requirements Lists (CDRLs) for assorted capscrews under solicitation number SPMYM324Q2016. The Defense Logistics Agency Land and Maritime has a requirement for various capscrews including socket head capscrews, socket flat countersunk head capscrews, hex head self-locking capscrews, and hex head capscrews. The CDRLs specify data items and certifications required from contractors, including Certificates of Compliance and Chemical and Mechanical Certification reports. Contractors must submit the required data with deliveries to the Portsmouth Naval Shipyard under code 245.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DLAD LOCAL and PROC Notes.docx | DOCX document | |
| 52.204-24 204-25 204-26 252.204-7016.docx | DOCX document | |
| SPMYM324Q2016 RFQ.docx | DOCX document | |
| SPMYM324Q2016 Security Agreement For NNPI.docx | DOCX document | |
| 252.204-7019 7020 Instructions for SPRS.docx | DOCX document | |
| SPMYM324Q2016 Combined Synopsis Solicitation.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT DATA REQUIREMENTS LIST
245.2C-0434-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET HEAD S/L CAPSCREW
E. CONTRACT/PR NO.
33554001-4
F. CONTRACTOR
1. DATA ITEM NO.
A001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
A002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical
& Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 &
252.232-7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC- 80678, the requirements of the contract section titled, Marking and
0 0 0
15. TOTAL
0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/21/23
I. APPROVED BY 245.2
X
J. DATE
12/30/2023
A. CONTRACT LINE ITEM NO. B. EXHIBIT
B
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET HEAD S/L CAPSCREW
E. CONTRACT/PR NO.
33554001-4
F. CONTRACTOR
1. DATA ITEM NO.
B001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
B002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical
& Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 &
252.232-7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC- 80678, the requirements of the contract section titled, Marking and
0 0 0
15. TOTAL
0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/21/23
I. APPROVED BY 245.2
X
J. DATE
A. CONTRACT LINE ITEM NO. B. EXHIBIT
C
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET HEAD S/L CAPSCREW
E. CONTRACT/PR NO.
33554001-4
F. CONTRACTOR
1. DATA ITEM NO.
C001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
C002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical
& Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 &
252.232-7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC- 80678, the requirements of the contract section titled, Marking and
0 0 0
15. TOTAL
0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/21/23
I. APPROVED BY 245.2
X
J. DATE
A. CONTRACT LINE ITEM NO. B. EXHIBIT
D
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET HEAD S/L CAPSCREW
E. CONTRACT/PR NO.
33554001-4
F. CONTRACTOR
1. DATA ITEM NO.
D001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
D002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical
& Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 &
252.232-7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC- 80678, the requirements of the contract section titled, Marking and
0 0 0
15. TOTAL
0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/21/23
I. APPROVED BY 245.2
X
J. DATE
245.2C-0441-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
E
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
CAP SCREW ANGLE
E. CONTRACT/PR NO.
33604001-4
F. CONTRACTOR
1. DATA ITEM NO.
E001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
E002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/26/2023
I. APPROVED BY 245.2
X
J. DATE
01/06/2024
A. CONTRACT LINE ITEM NO. B. EXHIBIT
F
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
CAP SCREW ANGLE
E. CONTRACT/PR NO.
33604001-4
F. CONTRACTOR
1. DATA ITEM NO.
F001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
F002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/26/2023
I. APPROVED BY 245.2
X
J. DATE
A. CONTRACT LINE ITEM NO. B. EXHIBIT
G
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
CAP SCREW ANGLE
E. CONTRACT/PR NO.
33604001-4
F. CONTRACTOR
1. DATA ITEM NO.
G001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
G002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/26/2023
I. APPROVED BY 245.2
X
J. DATE
A. CONTRACT LINE ITEM NO. B. EXHIBIT
H
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
CAP SCREW ANGLE
E. CONTRACT/PR NO.
33604001-4
F. CONTRACTOR
1. DATA ITEM NO.
H001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
H002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/26/2023
I. APPROVED BY 245.2
X
J. DATE
A. CONTRACT LINE ITEM NO. B. EXHIBIT
J
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
CAP SCREW ANGLE
E. CONTRACT/PR NO.
33604001-4
F. CONTRACTOR
1. DATA ITEM NO.
J001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
J002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/26/2023
I. APPROVED BY 245.2
X
J. DATE
245.2C-0443-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
K
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
CAP SCREW ANGLE
E. CONTRACT/PR NO.
33604011-4
F. CONTRACTOR
1. DATA ITEM NO.
K001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
K002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/27/2023
I. APPROVED BY 245.2
X
J. DATE
01/08/2024
A. CONTRACT LINE ITEM NO. B. EXHIBIT
L
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
CAP SCREW ANGLE
E. CONTRACT/PR NO.
33604011-4
F. CONTRACTOR
1. DATA ITEM NO.
L001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
L002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/27/2023
I. APPROVED BY 245.2
X
J. DATE
A. CONTRACT LINE ITEM NO. B. EXHIBIT
M
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
CAP SCREW ANGLE
E. CONTRACT/PR NO.
33604011-4
F. CONTRACTOR
1. DATA ITEM NO.
M001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
M002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/27/2023
I. APPROVED BY 245.2
X
J. DATE
245.2C-0444-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET HEAD CAP SCREW
E. CONTRACT/PR NO.
33614001-4
F. CONTRACTOR
1. DATA ITEM NO.
N001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
N002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/27/2023
I. APPROVED BY 245.2
X
J. DATE
245.2C-0444-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET HEAD CAP SCREW
E. CONTRACT/PR NO.
33614001-4
F. CONTRACTOR
1. DATA ITEM NO.
P001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
P002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/27/2023
I. APPROVED BY 245.2
X
J. DATE
245.2C-0444-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET HEAD CAP SCREW
E. CONTRACT/PR NO.
33614001-4
F. CONTRACTOR
1. DATA ITEM NO.
Q001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
Q002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/27/2023
I. APPROVED BY 245.2
X
J. DATE
245.2C-0444-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET HEAD CAP SCREW
E. CONTRACT/PR NO.
33614001-4
F. CONTRACTOR
1. DATA ITEM NO.
R001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
R002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
12/27/2023
I. APPROVED BY 245.2
X
J. DATE
245.2C-0459-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
HEX HEAD SLF LKG CAP SCREW &
HEX HEAD CAP SCREW
E. CONTRACT/PR NO.
40024011-2
F. CONTRACTOR
1. DATA ITEM NO.
S001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
S002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
01/02/2024
I. APPROVED BY 245.2
X
J. DATE
245.2C-0459-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
HEX HEAD SLF LKG CAP SCREW &
HEX HEAD CAP SCREW
E. CONTRACT/PR NO.
40024011-2
F. CONTRACTOR
1. DATA ITEM NO.
T001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15. TOTAL 0 1 0
1.DATA ITEM NO.
T002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
3. SUBTITLE
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a. ADDRESSEE b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
0 0 0
15. TOTAL 0 1 0
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
01/02/2024
I. APPROVED BY 245.2
X
J. DATE
| SPMYM324Q2016 Exhibit A |
| SPMYM324Q2016 Exhibit B |
| SPMYM324Q2016 Exhibit C |
| SPMYM324Q2016 Exhibit D |
| SPMYM324Q2016 Exhibit E |
| SPMYM324Q2016 Exhibit F |
| SPMYM324Q2016 Exhibit G |
| SPMYM324Q2016 Exhibit H |
| SPMYM324Q2016 Exhibit J |
| SPMYM324Q2016 Exhibit K |
| SPMYM324Q2016 Exhibit L |
| SPMYM324Q2016 Exhibit M |
| SPMYM324Q2016 Exhibit N |
| SPMYM324Q2016 Exhibit P |
| SPMYM324Q2016 Exhibit Q |
| SPMYM324Q2016 Exhibit R |
| SPMYM324Q2016 Exhibit S |
| SPMYM324Q2016 Exhibit T |
File details come from the government source that posted it. Updated .