This is a Material Ordering Data sheet specifying requirements for welding electrodes and rods under federal procurement specification MIL-DTL-23765/1F. The document establishes ordering parameters for 70S-3 type bare solid welding electrodes with a diameter of 0.045 inch, requiring suppliers to maintain active qualification on QPL-23765 (Qualified Products List).

Key technical and administrative requirements include: containers must comply with MIL-W-10430 packaging standards at Level-C with additional marking requirements per MIL-STD-129; a Certificate of Conformance must accompany all shipments; both argon plus 2% oxygen and carbon dioxide weld tests are required for qualification; maximum allowable defects are determined by Table VI of the specification; retest of unsatisfactory material is not permitted; and material must be supplied on standard 8-inch flange spools weighing 11-12 pounds. The applicable detail specification is MIL-DTL-23765/1F(1) dated 30 January 2026, with the general specification being MIL-DTL-23765C dated 16 August 2024. The ordering data references IDN N4523A 6276-1221 and ICN 38WAI99209. All unit, intermediate, and shipping containers require marking in accordance with MIL-STD-129, with reference to DLA Procurement Note C20 for further instructions.

View the file

Other files

File Type Posted
27Q00280002 - Electrode SF-30.pdf PDF
62761221 cdrl.pdf PDF
62761221 cdrl 2.pdf PDF
SPMYM227Q0028- Electrode -Solicitation.pdf PDF
62761221 aul.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MATERIAL ORDERING DATA

MIL-DTL-23765/1F

Any specification that is referenced in this Material Order Data sheet is required to be to the latest revision at time of award.

IDN: N4523A 6276-1221

ICN: 38WAI99209 KO: S03 KOI: 038

MIL-DTL-23765C Paragraph 6.2 Ordering Data (General Specification)

a. Title, number, and date of this specification: MIL-DTL-23765C, Electrodes and Rods -

Welding, Bare, Solid and Alloy Cored; General Specification for, dated 16 August 2024.

b. Title, number and date of the applicable detail specification: MIL-DTL-23765/1F(1), Electrodes and Rods - Welding, Bare, Solid and Alloyed Cored, Ordinary Strength and Low Alloy Steel, w/ Amendment 1 dated 30 January 2026.

c. Type: 70S-3 Form: Other (see Additional Requirements block) Diameter Size: .045 inch

d. When qualification is required: QPL REQUIRED. MUST BE ACTIVELY LISTED QPL-23765

e. Whether alloy identity testing of each electrode or rod after final marking is required:N/A

f. When the plastic spool burn test is required and how many spools are to be tested (see 3.6.7 and 4.4.7): N/A

g. When 12- or 18-inch rods are required (see 3.7.2) : N/A

h. Whether containers are required to be in accordance with MIL-W-10430 or

AWS A5.02/A5.02M (see 3.8): MIL-W-10430

i. Additional container requirements (see 3.8): N/A

j. Additional container marking requirements (see 3.9): MIL-STD-129 IN

ADDITION TO MIL-W-10430 REQUIREMENTS

k. When first article inspection is required (see 4.3): N/A

l. Maximum allowable number of defects (see 4.4.4.2 and 4.4.5.1): PER TABLE

VI OF THIS SPECIFICATION.

m. When a sampling plan for containers and container marking other than in accordance with MIL-W-10430 is required (see 4.4.6): N/A

n. Plastic spool burn test sampling requirements (see 4.4.7): N/A

o. When a CoC is not required (see 4.4.8): COC MUST ACCOMPANY

SHIPMENT

p. When a CoC indicating electrodes, rods, flux, and packaging are asbestos-free is required (see 4.4.8.9): N/A

q. Accepted analytical method agreed upon by the supplier and purchaser (see

4.6.2.3): N/A

r. When check mechanical property tolerances are not permitted for retest as part of receipt inspection (see 4.6.4.2): RETEST OF UNSATISFACTORY

MATERIAL PER 4.6.4.2 IS NOT PERMITTED FOR THIS PROCUREMENT

s. Packaging requirements (see 4.7, 5.1, and 6.5): PER PARA. 6.5 OF MIL-W-

10430. LEVEL-C

t. Requirements for first article inspection reports (see 6.2.1): N/A

Additional Requirements for MIL-DTL-23765: N/A

MIL-DTL-23765/1F Paragraph 6.2 Ordering Data (Detail Specification)

a. Title, number and date of the applicable detail specification: MIL-DTL-23765/1F, Electrodes and Rods - Welding, Bare, Solid and Alloyed Cored, Ordinary Strength and Low Alloy Steel, dated 30 January 2026.

b. For MIL-70 series electrodes and rods, whether the copper and phosphorus content should be restricted (see note 2 of table I and 6.1.12.1): N/A.

c. For MIL-80 series electrodes and rods, whether the copper content should be restricted (see note 5/ of table II and 6.1.12.2): N/A.

d. Mechanical properties of as-welded weld metal if other than as specified in 3.5. (see 3.5): N/A

e. For MIL-70S-1, -2, -3, -4, -5, and -6, whether the tests must be conducted in the stress-relieved condition in accordance with 3.5.1, 3.5.1.1, and 3.5.1.2 (either method (a) or (b)) (see table XI and note 3/ of table XII). N/A

f. For electrodes MIL-70S-7, -8, and -9, whether the tests must be conducted in the stress-relieved condition in accordance with 3.5.1 and 3.5.1.2 (method (a)) (see note 4/ of table XII).

N/A

g. Other base metal steel to be used in tests, if required (see note 14/ of table XII or note 13/ of table XIV, as applicable). N/A

h. For electrodes MIL-70S-2,-3,-4, -6 and 70S-3H, whether only the argon plus 2percent oxygen weld test or only the carbon dioxide weld test is required (see note 11/ of table XII and note 9/ of table XIII). BOTH THE Ar+2%O and CO2 WELD TESTS ARE REQUIRED.

I. For MIL-80S-3, whether the GMAW shielding gas should be argon plus 2 percent oxygen or argon plus 5 percent CO2 (see table XIV). N/A

j. For MIL-80S-1, -2, and -3, whether the holding time at temperature for the stress relief treatment should be in accordance with 3.5.1.2 (either method (a) or (b)) (see note 3/ of table

XIV). N/A

k. For MIL-80S-1 and -2, which specific brand name electrode and flux combination(s) must be used for conformance testing (see note 9/ of table XIV and 4.2.2). See current QPL for qualified combinations. N/A

l. Packaging requirements (see 5.1). PER MIL-W-10430 OF MIL-DTL-23765 AND MIL-STD-129

Additional Requirements for MIL-DTL-23765/1F: MATERIAL MUST BE SUPPLIED ON STANDARD 8-INCH FLANGE SPOOL (11-12 lb.)

All unit, intermediate, and shipping containers must be marked in accordance with MIL-STD-129.