25Q2467_CONFORMED.pdf

PDF 1 MB Posted

Attached to
LATTICE BEAM Federal contract opportunity
Solicitation number
SPMYM225Q2467
Issued by
Defense Logistics Agency Land and Maritime

About this file

This document is a Combined Synopsis/Solicitation for Commercial Items issued by DLA Maritime Puget Sound for the procurement of scaffolding equipment. The solicitation is a 100% Small Business Set-Aside (SBSA) for various scaffolding components including lattice beams, ledgers, standards, base collars, rosettes, staircases, guardrails, toeboards, and related accessories manufactured by Layher Scaffolding. The contract will be a firm fixed-price supply contract for delivery to Puget Sound Naval Shipyard in Bremerton, Washington, with a total of 37 line items across different scaffolding components.

Key details include a solicitation number SPMYM225Q2467, offer due date of August 14, 2025 at 3:00 PM, and delivery date of October 24, 2025. The NAICS code is 532490 with a small business size standard of $40,000,000. Offerors must complete pricing for each Contract Line Item Number (CLIN), provide their CAGE code, complete representations and certifications, include manufacturer information, and ensure current registration in the System for Award Management (SAM.gov). The solicitation requires detailed specifications for each scaffolding component, including dimensions, weight, material composition, and specific use requirements.

View the file

Other files for this federal contract opportunity

Other files attached to LATTICE BEAM, newest first.
File Type Posted
2 PG MOD TO SIGN.pdf PDF
25Q2467 LATTICE BEAM.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SEE ADDENDUM

(No Collect Calls)

SPMYM225Q2467 12-Aug-2025

b. TELEPHONE NUMBER

360-813-9244

8. OFFER DUE DATE/LOCAL TIME

03:00 PM 14 Aug 2025

5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

STANDARD FORM 1449 (REV. 2/2012)

Prescribed by GSA – FAR (48 CFR) 53.212

(TYPE OR PRINT)

(SIGNATURE OF CONTRACTING OFFICER)

ADDENDA ARE

26. TOTAL AWARD AMOUNT (For Gov t. Use Only )

23.

CODE 10. THIS ACQUISITION IS

SUCH ADDRESS IN OFFER

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT

BELOW IS CHECKED

TELEPHONE NO.

SPMYM29. ISSUED BY

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK

7. FOR SOLICITATION

INFORMATION CALL:

a. NAME

NAOMI H. LARSON

2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER

(TYPE OR PRINT)

30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER

30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA

0 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.

25. ACCOUNTING AND APPROPRIATION DATA

1. REQUISITION NUMBER

20.

ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

N4523A52130155

ARE NOT ATTACHED

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:

. YOUR OFFER ON SOLICITATION

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN

% FOR:SET ASIDE:UNRESTRICTED OR X

SMALL BUSINESSX

17a.CONTRACTOR/ CODE FACILITY

OFFEROR CODE

DLA MARITIME PUGET SOUND

ATTN: NAOMI LARSON

467 W ST

BREMERTON WA 98314

18a. PAYMENT WILL BE MADE BY CODE

RATED ORDER UNDER

DPAS (15 CFR 700)

13a. THIS CONTRACT IS A

13b. RATING

CODE15. DELIVER TO CODE N4523A 16. ADMINISTERED BY

12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

SEE SCHEDULE

14. METHOD OF SOLICITATION

RFQ IFB RFPX

PUGET SOUND NAVAL SHIPYARD

RECEIVING OFFICER PSNS

BLDG 514 D1

1400 FARRAGUT AVE

N4523A

BREMERTON WA 98314-5001

TEL: 360-476-7640 FAX:

FAX:

TEL: 360-813-9244 SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

8(A)

HUBZONE SMALL

BUSINESS

SIZE STANDARD:

$40,000,000

NAICS:

532490

X

OFFER DATED

29. AWARD OF CONTRACT: REF.

DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND

EMAIL:

TEL:

31c. DATE SIGNED

SEE SCHEDULE

SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT

24.22.21.19.

WOMEN-OWNED SMALL BUSINESS (WOSB)

ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

EDWOSB

32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

(CONTINUED)

PAGE 2 OF103

ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________

32a. QUANTITY IN COLUMN 21 HAS BEEN

RECEIVED INSPECTED

32b. SIGNATURE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE

37. CHECK NUMBER

FINALPARTIALCOMPLETE

36. PAYMENT35. AMOUNT VERIFIED

CORRECT FOR

34. VOUCHER NUMBER

FINAL

33. SHIP NUMBER

PARTIAL

38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY

41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT

41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE

42a. RECEIVED BY (Print)

42b. RECEIVED AT (Location)

42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS

STANDARD FORM 1449 (REV. 2/2012) BACK

Prescribed by GSA – FAR (48 CFR) 53.212

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

SEE SCHEDULE

20.

SCHEDULE OF SUPPLIES/ SERVICES

21.

QUANTITY UNIT

22. 23.

UNIT PRICE

24.

AMOUNT

19.

ITEM NO.

SPMYM225Q2467

Section SF 1449 - CONTINUATION SHEET

VENDOR INFORMATION

1. The Contractor’s POC is Phone:

Fax:

E-mail:

2. Buyer POC is NAOMI LARSON Phone: 385-591-9078 Fax:

E-mail: NAOMI.LARSON@DLA.MIL

3. Invoice Information:

The contractor shall utilize the electronic invoicing upon delivery of supplies indicated herein. Invoice may be submitted not more than one every two weeks. Invoices must be submitted electronically using Wide Area Work Flow (WAWF) – Receipt and Acceptance. The contractor shall self-register at the web site: https://wawf.eb.mil.

Contractor training is available on the Internet at https://wawftraining.eb.mil.

Additional support can be accessed by calling the NAVY WAWF Assistance Line: 1-800-756-4571 See clause 252.232-7006 for WAWF table.

4. Inspection Level:

QA 4 7 days inspection

5. Defense Biometric Identification System (DBIDS):

Effective 14 August 2017, NCACS credentials will no longer be accepted for base access. Any new contractor, vendor or supplier requesting base access will be required to obtain a Defense Biometric Identification System (DBIDS) credential. NCACS credentials will no longer be issued. Only DBIDS credentials will be issued to ALL contractors, vendors and suppliers seeking base access AFTER 30 June 2017. Defense Biometric Identification System (DBIDS) increases installation security and communications by receiving frequent database updates on changes to personnel/credential status, law enforcement warrants, lost/stolen cards, and force protection conditions.

The system provides continuous vetting anytime the DBIDS card is scanned at an installation entry point.

If you currently have a Navy Commercial Access Control System (NCACS) card, the following is required to get a DBIDS credential:

Present your NCACS Card and a completed copy of the SECNAV FORM 5512/1 to the base Visitor Control Center (VCC) representative.

The VCC will pull up your information in the computer, ensuring all information is current and correct.

Once your information is validated, a temporary DBIDS credential is provided.

Your temporary credential will have an expiration date, prior to which you will need to obtain your permanent DBIDS credential (~ 180 days).

For each additional U.S. Navy installation to which you need access, the first time you visit you only need to bring your DBIDS credential and statement of purpose for base access when arriving at the Visitor Control Center.

The representative will enter base access authorization and then you may proceed to work.

If you do NOT have an NCACS Card, the following is required to obtain a DBIDS credential:

Present a letter or official document from any government sponsoring organization that provides the purpose for your access.

Present valid identification, such as a passport or Real ID Act-compliant state driver's license.

Present a completed copy of the SECNAV 5512/1 form to obtain your background check.

Upon completion of the background check, the Visitor Control Center representative will complete the

DBIDS enrollment process, which includes your photo, finger prints, base restrictions, and several other assessments; after all this is done, you will be provided with your new DBIDS credential.

All deliveries must pass through the base Truck Inspection Station. All delivery vehicles are subject to inspection.

Drivers should expect delays due to heightened security.

For access to the main, perimeter gates at any Navy Base Kitsap installation, contractors are required to be a US Citizen and have either:

(a) DBIDS badge or

(b) Request a One-day Visitor badge at Pass & ID. Be prepared to present:

-Photo ID -Original proof of citizenship (any one of the following is acceptable):

State Certified Birth Certificate (must have the raised seal) Unexpired U.S. passport/Passport Card Alien Registration Card

Enhanced state-issued driver's license only accepted from Michigan, Minnesota, New York, Vermont, and Washington. Real ID licenses are not accepted at this time.

Naturalization papers Certificate/Statement of Birth Born Abroad)

-Current vehicle registration and insurance -Bill of lading that has the delivery address on it

Please note: The DBIDS badge does not give access through the second, Operational Area (OA) gate to lower base Bangor or to the Controlled Industrial Area (CIA) at Puget Sound Naval Shipyard (PSNS). To gain access to either the OA Gate or CIA area, a Navy Region Bangor or NAVSEA Badge is required.

To request a NAVY REGION NW badge, https://www.bavr.cnic.navy.mil/. Sponsor email is trina.f.williamson.civ@us.navy.mil

To request a NAVSEA badge, call PSNS Pass & ID 360-476-4882.

FOR MORE INFORMATION VISIT: https://www.cnic.navy.mil/om/dbids.html

252.204-7012 (DEV 2024-O0013)

THE FOLLOWING CLASS DEVIATION SUPERSEDES ANY PRIOR VERSION OF DFARS

CLAUSE 252.204-7012.

252.204-7012 SAFEGUARDING COVERED DEFENSE INFORMATION AND CYBER

INCIDENT REPORTING (MAY 2024) (DEVIATION 2024-O0013)

(a) Definitions. As used in this clause— Adequate security means protective measures that are commensurate with the consequences and probability of loss, misuse, or unauthorized access to, or modification of information. Compromise means disclosure of information to unauthorized persons, or a violation of the security policy of a system, in which unauthorized intentional or unintentional disclosure, modification, destruction, or loss of an object, or the copying of information to unauthorized media may have occurred. Contractor attributional/proprietary information means information that identifies the contractor(s), whether directly or indirectly, by the grouping of information that can be traced back to the contractor(s) (e.g., program description, facility locations), personally identifiable information, as well as trade secrets, commercial or financial information, or other commercially sensitive information that is not customarily shared outside of the company. Controlled technical information means technical information with military or space application that is subject to controls on the access, use, reproduction, modification, performance, display, release, disclosure, or dissemination.

Controlled technical information would meet the criteria, if disseminated, for distribution statements B through F using the criteria set forth in DoD Instruction 5230.24, Distribution Statements on Technical Documents. The term does not include information that is lawfully publicly available without restrictions. Covered contractor information system means an unclassified information system that is owned, or operated by or for, a contractor and that processes, stores, or transmits covered defense information. Covered defense information means unclassified controlled technical information or other information, as described in the Registry at http://www.archives.gov/cui/registry/category-list.html, that requires safeguarding or dissemination controls pursuant to and consistent with law, regulations, and Governmentwide policies, and is—

(1) Marked or otherwise identified in the contract, task order, or delivery order and provided to the contractor by or on behalf of DoD in support of the performance of the contract; or

(2) Collected, developed, received, transmitted, used, or stored by or on behalf of the contractor in support of the performance of the contract. Cyber incident means actions taken through the use of computer networks that result in a compromise or an actual or potentially adverse effect on an information system and/or the information residing therein. Forensic analysis means the practice of gathering, retaining, and analyzing computer-related data for investigative purposes in a manner that maintains the integrity of the data. Information system means a discrete set of information resources organized for the collection, processing, maintenance, use, sharing, dissemination, or disposition of information. Malicious software means computer software or firmware intended to perform an unauthorized process that will have adverse impact on the confidentiality, integrity, or availability of an information system. This definition includes a virus, worm, Trojan horse, or other code-based entity that infects a host, as well as spyware and some forms of adware. Media means physical devices or writing surfaces including, but is not limited to, magnetic tapes, optical disks, magnetic disks, large-scale integration memory chips, and printouts onto which covered defense information is recorded, stored, or printed within a covered contractor information system. Operationally critical support means supplies or services designated by the Government as critical for airlift, sealift, intermodal transportation services, or logistical support that is essential to the mobilization, deployment, or sustainment of the Armed Forces in a contingency operation. Rapidly report means within 72 hours of discovery of any cyber incident.

Technical information means technical data or computer software, as those terms are defined in the clause at DFARS 252.227-7013, Rights in Technical Data—Other Than Commercial Products and Commercial Services, regardless of whether or not the clause is incorporated in this solicitation or contract. Examples of technical information include research and engineering data, engineering drawings, and associated lists, specifications, standards, process sheets, manuals, technical reports, technical orders, catalog-item identifications, data sets, studies and analyses and related information, and computer software executable code and source code.

(b) Adequate security. The Contractor shall provide adequate security on all covered contractor information systems. To provide adequate security, the Contractor shall implement, at a minimum, the following information security protections:

(1) For covered contractor information systems that are part of an Information Technology (IT) service or system operated on behalf of the Government, the following security requirements apply:

(i) Cloud computing services shall be subject to the security requirements specified in the clause 252.239-7010, Cloud Computing Services, of this contract.

(ii) Any other such IT service or system (i.e., other than cloud computing) shall be subject to the security requirements specified elsewhere in this contract.

(2) For covered contractor information systems that are not part of an IT service or system operated on behalf of the Government and therefore are not subject to the security requirement specified at paragraph (b)(1) of this clause, the following security requirements apply:

(i) Except as provided in paragraph (b)(2)(ii) of this clause, the covered contractor information system shall be subject to the security requirements in National Institute of Standards and Technology (NIST) Special Publication (SP) 800-171, “Protecting Controlled Unclassified Information in Nonfederal Information Systems and Organizations”, Revision 2 (available via the internet at http://dx.doi.org/10.6028/NIST.SP.800-171).

(ii)(A) The Contractor shall implement NIST SP 800-171, as soon as practical, but not later than December 31, 2017. For all contracts awarded prior to October 1, 2017, the Contractor shall notify the DoD Chief Information Officer (CIO), via email at osd.dibcsia@mail.mil, within 30 days of contract award, of any security requirements specified by NIST SP 800-171 not implemented at the time of contract award. (B) The Contractor shall submit requests to vary from NIST SP 800-171 in writing to the Contracting Officer, for consideration by the DoD CIO.

The Contractor need not implement any security requirement adjudicated by an authorized representative of the DoD CIO to be nonapplicable or to have an alternative, but equally effective, security measure that may be implemented in its place. (C) If the DoD CIO has previously adjudicated the contractor’s requests indicating that a requirement is not applicable or that an alternative security measure is equally effective, a copy of that approval shall be provided to the Contracting Officer when requesting its recognition under this contract. (D) If the Contractor intends to use an external cloud service provider to store, process, or transmit any covered defense information in performance of this contract, the Contractor shall require and ensure that the cloud service provider meets security requirements equivalent to those established by the Government for the Federal

Risk and Authorization Management Program (FedRAMP) Moderate baseline (https://www.fedramp.gov/resources/documents/) and that the cloud service provider complies with requirements in paragraphs (c) through (g) of this clause for cyber incident reporting, malicious software, media preservation and protection, access to additional information and equipment necessary for forensic analysis, and cyber incident damage assessment. (3) Apply other information systems security measures when the Contractor reasonably determines that information systems security measures, in addition to those identified in paragraphs (b)(1) and (2) of this clause, may be required to provide adequate security in a dynamic environment or to accommodate special circumstances (e.g., medical devices) and any individual, isolated, or temporary deficiencies based on an assessed risk or vulnerability. These measures may be addressed in a system security plan.

(c) Cyber incident reporting requirement.

(1) When the Contractor discovers a cyber incident that affects a covered contractor information system or the covered defense information residing therein, or that affects the contractor’s ability to perform the requirements of the contract that are designated as operationally critical support and identified in the contract, the Contractor shall—

(i) Conduct a review for evidence of compromise of covered defense information, including, but not limited to, identifying compromised computers, servers, specific data, and user accounts. This review shall also include analyzing covered contractor information system(s) that were part of the cyber incident, as well as other information systems on the Contractor’s network(s), that may have been accessed as a result of the incident in order to identify compromised covered defense information, or that affect the Contractor’s ability to provide operationally critical support;

and

(ii) Rapidly report cyber incidents to DoD at https://dibnet.dod.mil.

(2) Cyber incident report. The cyber incident report shall be treated as information created by or for DoD and shall include, at a minimum, the required elements at https://dibnet.dod.mil.

(3) Medium assurance certificate requirement. In order to report cyber incidents in accordance with this clause, the Contractor or subcontractor shall have or acquire a DoD-approved medium assurance certificate to report cyber incidents.

For information on obtaining a DoD-approved medium assurance certificate, see https://public.cyber.mil/eca/.

(d) Malicious software. When the Contractor or subcontractors discover and isolate malicious software in connection with a reported cyber incident, submit the malicious software to DoD Cyber Crime Center (DC3) in accordance with instructions provided by DC3 or the Contracting Officer. Do not send the malicious software to the Contracting Officer.

(e) Media preservation and protection. When a Contractor discovers a cyber incident has occurred, the Contractor shall preserve and protect images of all known affected information systems identified in paragraph (c)(1)(i) of this clause and all relevant monitoring/packet capture data for at least 90 days from the submission of the cyber incident report to allow DoD to request the media or decline interest.

(f) Access to additional information or equipment necessary for forensic analysis. Upon request by DoD, the Contractor shall provide DoD with access to additional information equipment that is necessary to conduct a forensic analysis.

(g) Cyber incident damage assessment activities. If DoD elects to conduct a damage assessment, the Contracting Officer will request that the Contractor provide all of the damage assessment information gathered in accordance with paragraph (e) of this clause.

(h) DoD safeguarding and use of contractor attributional/proprietary information. The Government shall protect against the unauthorized use or release of information obtained from the contractor (or derived from information obtained from the contractor) under this clause that includes contractor attributional/proprietary information, including such information submitted in accordance with paragraph (c). To the maximum extent practicable, the Contractor shall identify and mark attributional/proprietary information.

In making an authorized release of such information, the Government will implement appropriate procedures to minimize the contractor attributional/proprietary information that is included in such authorized release, seeking to include only that information that is necessary for the authorized purpose(s) for which the information is being released.

(i) Use and release of contractor attributional/proprietary information not created by or for DoD. Information that is obtained from the contractor (or derived from information obtained from the contractor) under this clause that is not created by or for DoD is authorized to be released outside of DoD—

(1) To entities with missions that may be affected by such information;

(2) To entities that may be called upon to assist in the diagnosis, detection, or mitigation of cyber incidents;

(3) To Government entities that conduct counterintelligence or law enforcement investigations;

(4) For national security purposes, including cyber situational awareness and defense purposes (including with Defense Industrial Base (DIB) participants in the program at 32 CFR part 236); or

(5) To a support services contractor (“recipient”) that is directly supporting Government activities under a contract that includes the clause at 252.204-7009, Limitations on the Use or Disclosure of Third-Party Contractor Reported Cyber Incident Information.

(j) Use and release of contractor attributional/proprietary information created by or for DoD. Information that is obtained from the contractor (or derived from information obtained from the contractor) under this clause that is created by or for DoD (including the information submitted pursuant to paragraph (c) of this clause) is authorized to be used and released outside of DoD for purposes and activities authorized by paragraph (i) of this clause, and for any other lawful Government purpose or activity, subject to all applicable statutory, regulatory, and policy based restrictions on the Government’s use and release of such information.

(k) The Contractor shall conduct activities under this clause in accordance with applicable laws and regulations on the interception, monitoring, access, use, and disclosure of electronic communications and data.

(l) Other safeguarding or reporting requirements. The safeguarding and cyber incident reporting required by this clause in no way abrogates the Contractor’s responsibility for other safeguarding or cyber incident reporting pertaining to its unclassified information systems as required by other applicable clauses of this contract, or as a result of other applicable U.S. Government statutory or regulatory requirements.

(m) Subcontracts. The Contractor shall—

(1) Include this clause, including this paragraph (m), in subcontracts, or similar contractual instruments, for operationally critical support, or for which subcontract performance will involve covered defense information, including subcontracts for commercial products or commercial services, without alteration, except to identify the parties. The Contractor shall determine if the information required for subcontractor performance retains its identity as covered defense information and will require protection under this clause, and, if necessary, consult with the Contracting Officer; and

(2) Require subcontractors to—

(i) Notify the prime Contractor (or next higher-tier subcontractor) when submitting a request to vary from a NIST SP 800-171 security requirement to the Contracting Officer, in accordance with paragraph (b)(2)(ii)(B) of this clause; and

(ii) Provide the incident report number, automatically assigned by DoD, to the prime Contractor (or next higher-tier subcontractor) as soon as practicable, when reporting a cyber incident to DoD as required in paragraph (c) of this clause.

-End of Clause-

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0001 18 Each

LATTICE BEAM

FFP

18 EA. LAYHER HA KD XL LATTICE BEAMS, 1.00M, MANUFACTURER

P/N: 5975.200, THIS PARTICULAR

PART NUMBER IS CUSTOM BY MANUFACTURER DUE TO THE

DIMENSIONS

SEE SALIENT CHARACTERISTICS:

Lattice Beams must have dimensions: 3'3" L x 2'7" W Lattice Beams must weigh 23.18 lbs Lattice Beams must be made of aluminum Lattice beams must be made for scaffold roofing

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 5975.200

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications for technical evaluation. Quote packages missing manufacturer specifications will be deemed incomplete and will not be included for consideration.

FOB: Destination

BRAND NAME/SOLE SOURCE: BN

MILSTRIP: N4523A52110155

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

SIGNAL CODE: A

PSC CD: 5440

NET AMT

0002 10 Each

O-LATTICE BEAM

FFP

10 EA. LAYHER AR O-LATTICE BEAMS, 5.144 X 0.5M, W.SPI,

MANUFACTURER P/N: 2674.514

SEE SALIENT CHARACTERISTICS:

Lattice beams must have 4 wedge-heads Lattice beams must be made of steel Lattice beams must have dimensions: 16'-10" x 1'-7" Lattice beams must be 112.64 lbs

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2674.514

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications for technical evaluation. Quote packages missing manufacturer specifications will be deemed incomplete and will not be included for consideration.

FOB: Destination

BRAND NAME/SOLE SOURCE: BN

MILSTRIP: N4523A52110156

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0003 74 Each

O-LEDGER

FFP

74 EA. LAYHER AR O-LEDGERS, LW, 0.73 METERS, MANUFACTURER

P/N: 2601.073

SEE SALIENT CHARACTERISTICS:

Ledgers must have dimensions: 2"-5" ledgers must be made of steel ledgers must have the wedge head design with an Autolock function

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2601.073

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications for technical evaluation. Quote packages missing manufacturer specifications will be deemed incomplete and will not be included for consideration.

FOB: Destination

BRAND NAME/SOLE SOURCE: BN

MILSTRIP: N4523A52110157

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0004 151

LEDGER

FFP

151 EA. LAYHER AR O-LEDGERS, LW, 2.57 METERS, MANUFACTURER

P/N: 2601.257

SEE SALIENT CHARACTERISTICS:

Ledgers must have dimensions: 8'-5" ledgers must be made of steel ledgers must have the wedge head design with an Autolock function

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2601.257

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications for technical evaluation. Quote packages missing manufacturer specifications will be deemed incomplete and will not be included for consideration.

FOB: Destination

BRAND NAME/SOLE SOURCE: BN

MILSTRIP: N4523A52110158

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0005 34 Each

BASE COLLAR

FFP

34 EA. LAYHER BASE COLLARS, AR, MANUFACTURER P/N: 2602.2000

SEE SALIENT CHARACTERISTICS:

base collars must fit with steel standards base collars must have the following dimensions: 0"-1 O" base collars must be 3.08 lbs.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2602.2000

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications for technical evaluation. Quote packages missing manufacturer specifications will be deemed incomplete and will not be included for consideration.

FOB: Destination

BRAND NAME/SOLE SOURCE: BN

MILSTRIP: N4523A52110159

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0006 8 Each

ROSETTE

FFP

8 EA. LAYHER ROSETTES, 22MM, WS CLAMP, FORGED,

MANUFACTURER P/N: 2602.022

SEE SALIENT CHARACTERISTICS:

Rosettes must be clampable to any point of a steel standard Rosettes must allow up to 6 ledgers or diagonal braces to be connected to it Rosette dimensions must be: 0'-5" Rosettes must weigh 2.20 lb.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2602.022

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications for technical evaluation. Quote packages missing manufacturer specifications will be deemed incomplete and will not be included for consideration.

FOB: Destination

BRAND NAME/SOLE SOURCE: BN

MILSTRIP: N4523A52110160

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0007 5 Each

STANDARD

FFP

5 EA. LAYHER STANDARDS, VERTICAL W/O SPIGOT, 4'11",

MANUFACTURER P/N: 2604.150

SEE SALIENT CHARACTERISTICS:

Standards must be made of galvanized steel tubing Standards must come with rosettes at every 50 CM for a max of 8 connections Standards must come without the spigot Standards must haver dimensions: 4'-11" Standards must weigh under 15 lb.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2604.150

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications for technical evaluation. Quote packages missing manufacturer specifications will be deemed incomplete and will not be included for consideration.

FOB: Destination

BRAND NAME/SOLE SOURCE: BN

MILSTRIP: N4523A52110161

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0008 68 Each

STANDARD

FFP

68 EA. LAYHER AR STANDARDS, VERTICAL, W/OUT SPIGOT, 6'7",

MANUFACTURER P/N: 2604.200

SEE SALIENT CHARACTERISTICS:

Standards must be made of galvanized steel tubing Standards must come with rosettes at every 50 CM for a max of 8 connections Standards must come without the spigot Standards must haver dimensions: 6'-6" Standards must weigh 19. 75 lb.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2604.200

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications for technical evaluation. Quote packages missing manufacturer specifications will be deemed incomplete and will not be included for consideration.

FOB: Destination

BRAND NAME/SOLE SOURCE: BN

MILSTRIP: N4523A52110162

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0009 73 Each

SPIGOT

FFP

73 EA. LAYHER AR SPIGOTS FOR 2604 AND 2605 STANDARD

VERTICALS, MANUFACTURER P/N:

2605.000

SEE SALIENT CHARACTERISTICS:

Spigot scaffolding must be made of steel Spigot dimensions must be: 1 '-8" Spigot must weigh 3.52 lb each Spigots must fit vertical standards 2619 and 2604

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2605.000

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52110163

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0010 2 Each

STAIRCASE

FFP

2 EA. LAYHER ALUMINUM SCAFFOLDING STAIRCASES,

MANUFACTURER P/N: 2635.257

SEE SALIENT CHARACTERISTICS:

Stair case scaffolding must be made of aluminum Stair case scaffolding dimensions must be: 8'-5" L/H x 2'-1" W Stair case scaffolding weight must be 64.37 pounds each Stair case scaffolding must be stair class B

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2635.257

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52110164

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0011 2 Each

GUARDRAIL

FFP

2 EA. LAYHER AR WEDGE STAIRCASE GUARDRAILS, MANUFACTURER

P/N: 2638.258

SEE SALIENT CHARACTERISTICS:

Stairway guardrail must be made of galvanized steel stairway guardrail dimensions must be: 8'-5" stairway guardrails must weigh under 40 lb. each stairway guardrails must have a swiveling wedge head

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2638.258

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52120155

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0012 2 Each

TOEBOARD

FFP

2 EA. LAYHER AR O-STEEL TOE BOARDS, 0.73M, T18, MANUFACTURER

P/N: 2643.073

SEE SALIENT CHARACTERISTICS:

Scaffolding Toe boards must be made of Steel Scaffolding Toe boards must be made for decking with O-insertion and longitudinal and end sides Scaffolding Toe boards dimensions: 2'-5" L x 6" W Scaffolding Toe boards must weigh 3.75 lbs.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2643.073

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52120156

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0013 14 Each

TOEBOARD

FFP

14 EA. LAYHER AR O-STEEL TOE BOARDS, 2.57M, T18,

MANUFACTURER P/N: 2643.257

SEE SALIENT CHARACTERISTICS:

Scaffolding Toe boards must be made of Steel Scaffolding Toe boards must be made for decking with O-insertion and longitudinal and end sides Scaffolding Toe boards dimensions: 8'-5" L x 6" Scaffolding Toe boards must weigh under 12 lbs.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2643.257

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52120157

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0014 2 Each

LEDGER

FFP

2 EA. LAYHER AR O-LEDGER LW, 2.57M, REINFORCED, T14

MANUFACTURER P/N: 2672.257

SEE SALIENT CHARACTERISTICS:

Bridging ledgers must be made of steel Bridging ledgers must have dimensions: 8' -5" Bridging ledgers must be 31.46 lbs.

Bridging ledgers must have wedge head design with Autolock function

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2672.257

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52120158

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0015 4 Each

LEDGER

FFP

4 EA. LAYHER AR O-LEDGER LW, 3.64M, PB, 2.57 X 2.57 M,

MANUFACTURER P/N: 2678.257

SEE SALIENT CHARACTERISTICS:

ledgers must be made of steel ledgers must have dimensions: 11'-11" ledgers must be under 27 lbs.

ledgers must be made for horizontal-diagonal use, with wedge heads

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2678.257

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52120159

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0016 22 Each

DIAGONAL BRACE

FFP

22 EA. LAYHER DIAGONAL BRACES, LW, 0.73 X 2.00M (2'5"),

MANUFACTURER P/N: 2683.073

SEE SALIENT CHARACTERISTICS:

Diagonal braces must be made of steel Diagonal braces must have dimensions: 7'-0" Diagonal braces must have wedge locks Diagonal braces must be 15.65 lbs.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:2683.073

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52120160

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0017 35 Each

DIAGONAL BRACE

FFP

35 EA. LAYHER DIAGONAL BRACES, LW, 0.73 X 2.00M (2'5"), P/N:

2683257B

SEE SALIENT CHARACTERISTICS:

Diagonal braces must be made of steel Diagonal braces must have dimensions: 10'-5" Diagonal braces must have wedge locks Diagonal braces must be 22.05 lbs.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 2683.073

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52120161

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0018 4 Each

STEEL DECKING

FFP

4 EA. LAYHER CT-FILLER STEEL DECKS, T9, 2.57 X 0.19M,

MANUFACTURER P/N: 3863.257

SEE SALIENT CHARACTERISTICS:

Steel decking must be made of galvanized steel Steel decking must have integrated swiveling lift-off and tilt-preventer Steel decking must be perforated Steel decking dimensions: 8'-5" L x 7" W Steel decking must weigh under 29 lbs.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 3863.257

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52120162

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0019 2 Each

GAP COVER

FFP

2 EA. LAYHER BE ST-GAP COVERS, 2.57 X 0.32M, MANUFACTURER P/N:

3881.004

SEE SALIENT CHARACTERISTICS:

Cover Plates must fit widths up to 20 CM Cover plates must be made of steel grating Cover plates must be 8'-5" L x 1 '-0" W Cover plates must weigh 18.74 lbs.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 3881.004

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52120163

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0020 56

STEEL DECKING

FFP

56 EA. LAYHER BBE O-STEEL DECKING, LW, 2.57 X 0.32M

MANUFACTURER P/N: 3890.257

SEE SALIENT CHARACTERISTICS:

Steel decking must be made of galvanized steel steel decking must have integrated swiveling lift-off and tilt preventer Steel decking must be perforated Steel decking dimensions: 8'-5" L x 1 '-0" W Steel decking must weigh under 38 lbs

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 3890.257

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52120164

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0021 76 Each

LOCKING PIN

FFP

76 EA. LAYHER LOCKING PINS, RED, MANUFACTURER P/N: 4000.001

SEE SALIENT CHARACTERISTICS:

Locking pins must be red in color Locking pins dimensions: 11 MM (Diameter)

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 4000.001

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52130155

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0022 34 Each

BASE PLATE

FFP

34 EA. LAYHER ADJUSTABLE BASE PLATES, 0.60M (2'0"),

MANUFACTURER P/N: 4001.060

SEE SALIENT CHARACTERISTICS:

Base Plates must be adjustable Base plates must have color notched markings to protect against overwinding when adjusting Base plate must have a max spindle travel of 41 CM Base plate dimensions must be: 1'-10" Base plate must weigh 1.24 lbs

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN: 4001.060

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52130156

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0023 8 Each

RIGHT ANGLE CLAMP

FFP

8 EA. LAYHER RIGHT ANGLE CLAMP, 22M, WS, MANUFACTURER P/N:

4700.022

SEE SALIENT CHARACTERISTICS:

Clamps must be Class BB, C3, EN 74-1 (quality standards) Clamps must be made of steel Clamps must be made for right-angle connection to tubing Clamps must be drop-forged They must be clamps used for steel and aluminum tubing only They must weigh 2.87 lbs

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:4700.022

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52130157

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0024 300 Each

BOLT

FFP

300 EA. LAYHER SPECIAL BOLT, M12 X 60, WITH NUT,

MANUFACTURER P/N: 4905.062

SEE SALIENT CHARACTERISTICS:

Hex Bolt dimensions: M12 x 60 Hex Bolt must come with nut Hex Bolts must be made for bolting scaffolding standards to Spigots

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:4905.062

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52130158

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0025 36 Each

BRACE

FFP

36 EA. LAYHER HA LD HORIZONTAU DIAGONAL BRACES, 1.00 X 2.57

MM, MANUFACTURER P/N: 5939.100

SEE SALIENT CHARACTERISTICS:

Diagonal braces must have dimensions: 8'-5" x 3'-3" Diagonal braces must weigh 9.26 lbs. each Braces must used for diagonal and horizontal roof scaffolding Braces must be aluminum

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5939.100

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52130159

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0026 24 Each

BRACE STIFFENER

FFP

24 EA. LAYHER HA LD BRACES STIFFENERS, 2.57 M, HORIZONTAL

CLAWS, MANUFACTURER P/N: 5940.257

SEE SALIENT CHARACTERISTICS:

Brace Stiffeners must be made to fit in scaffolding roof truss posts Brace stiffeners must be made of aluminum Brace stiffeners must have dimensions: 2.57 M Brace stiffeners must have horizontal claws

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5940.257

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52130160

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0027 24 Each

ROOF LEDGER

FFP

24 EA. LAYHER KD ROOF LEDGERS, 2.57M, MANUFACTURER P/N:

5972.257

SEE SALIENT CHARACTERISTICS:

Roof ledgers must have dimensions: 8'-5" L Roof ledgers must weigh 8.26 lbs Roof ledgers must be manufactured to be fitted to the bottom chords of roof scaffolding near the eaves

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5972.257

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52130161

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0028 8 Each

ROOF SHEET

FFP

8 EA. ROOF SHEETS, 2.57 X 17.00, MANUFACTURER P/N: 5972.308

SEE SALIENT CHARACTERISTICS:

Roof sheets must be made of flame-retardant tarpaulin according to standard ISO 3795' Roof sheets must be UV and heat resistant Roof sheets must be made of PVC-coated polyester fabric Roof sheets must have dimensions: 55'-9" L x 8'5" Roof sheets must weigh 78.26 lbs

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5972.308

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52130162

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0029 2 Each

GABLE

FFP

2 EA. LAYHER TARPAULIN GABLES, 11.5 M, MANUFACTURER P/N:

5972.382

SEE SALIENT CHARACTERISTICS:

Gables must be Flame retardant according to ISO 3795 Gables must have dimensions: 31 '-9" Gables must weigh under 40 lb.

Gables must be made of PVC tarpaulin

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5972.382

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52130163

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0030 18 Each

SUPPORT

FFP

18 EA. LAYHER SUPPORTS, 11.5 M, MANUFACTURER P/N: 5975.073

SEE SALIENT CHARACTERISTICS:

Supports must have dimensions: 0. 73 M Must be roof supports manufactured to stabilize roof of tent awarded in contact

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5975.073

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52130164

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0031 125 Each

SCREW

FFP

125 EA. LAYHER HA KD XL HEX SCREWS, M12X90 WITH NUT,

MANUFACTURER P/N: 5975.092

SEE SALIENT CHARACTERISTICS:

Hex screw must come with nut, dimensions for both: M12 x 60

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5975.092

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52140155

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0032 18 Each

EAVE SECTION

FFP

18 EA. LAYHER HA KD XL EAVES SECTIONS, MANUFACTURER P/N:

5975.100

SEE SALIENT CHARACTERISTICS:

Eaves Sections must have the following dimensions: 6'-6" L x 2-7" W Eaves sections must weigh 31.53 lbs.

Eaves Sections must have a closed, rounded corner on one side Eave sections must be manufactured to fit with lattice girders and ridge sections for awarded scaffolding tent

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5975.100

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52140156

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0033 9 Each

RIDGE SECTION

FFP

9 EA. LAYHER HA KD XL 18 DEGREE RIDGE SECTIONS,

MANUFACTURER P/N: 5975.110

SEE SALIENT CHARACTERISTICS:

Ridge sections must come to an 18 degree angle Ridge section must have dimensions: 6'-11" L x 2'-7" W Ridge sections must weigh 54 lbs.

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5975.110

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52140157

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0034 16 Each

WALL CASSETTE

FFP

16 EACH LAYHER WALL CASSETTES, 0.73 X 1.0M, MANUFACTURER

P/N: 5980.073

SEE SALIENT CHARACTERISTICS:

Wall Cassettes must have dimensions: 2'-5" L x 3'-3" W Wall Cassettes must weigh 23.15 lb. each Wall Cassettes must be made from aluminum sections with galvanized sheet steel inserts Wall Cassettes must a surrounding rubber seal for mating up to the next wall

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5980.073

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications

MILSTRIP: N4523A52140158

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0035 70 Each

WALL CASSETTE

FFP

70 EA. LAYHER WALL CASSETTES, 2.57 X 1.0M, VENDOR P/N: 59802578,

MANUFACTURER P/N: 5980.257

SEE SALIENT CHARACTERISTICS:

Wall Cassettes must have dimensions: 8'-5" L x 3'-3" W Wall Cassettes must weigh 48.94 lbs each Wall Cassettes must be made from aluminum sections with galvanized sheet steel inserts Wall Cassettes must a surrounding rubber seal for mating up to the next wall

BRAND NAME OR EQUAL TO:

MFR: LAYHER SCAFFOLDING

PN:5980.257

MFR NAME:______________________________________

BRAND:__________________________________________

NO:_____________________________________________

Note: Vendors offering equal-to material must include manufacturer specifications for technical evaluation. Quote packages missing manufacturer specifications will be deemed incomplete and will not be included for consideration.

FOB: Destination

BRAND NAME/SOLE SOURCE: BN

MILSTRIP: N4523A52140159

PURCHASE REQUEST NUMBER: N4523A52130155

PROJECT: 6X3

0036 16 Each

WALL CASSETTE

FFP

16 EA. LAYHER CORNER WALL CASSETTES, 90 DEGREES, 1.0M,

VENDOR P/N: 59850108, MANUFACTURER P/N: 5985.010

SEE SALIENT CHARACTERISTICS:

Wall Cassettes must have dimensions: 6" x 3'-3" Wall Cassettes must weigh 13.67 Wall Cassettes must come to a 90 degree angle for corners Wall Cassettes must be made from aluminum sections with galvanized sheet steel inserts Wall Cassettes must a surrounding rubber seal for mating up to the next wall

BRAND NAME OR EQUAL TO:

M…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .