This document contains the salient characteristics for a Vacuum Recovery Unit as part of a federal contract opportunity. The key details are:
The Vacuum Recovery Unit must have specific capabilities/features including a 150 HP electrical motor, a Roots dresser blower, 37 Teflon coated filter bags, sound attenuation to keep noise under 84 DBA, a HEPA safety filter, and various other components. The unit must be NRTL certified, come with operation/maintenance manuals, and have a one-year warranty. Load testing of the crane lifting points/padeyes and non-destructive testing of the attachment welds are required prior to delivery. Access to the work site at Naval Base Kitsap, Bangor requires obtaining a visitor security badge through the online Base Authorization and Visit Request (BAVR) system.
The related federal contract opportunity is for the procurement of a Vacuum Recovery System by the Defense Logistics Agency (DLA) Maritime Puget Sound Naval Shipyard/TRF Bangor. It will be a firm fixed price contract awarded under FAR Part 12 - Acquisition of Commercial Items and FAR Part 13 - Simplified Acquisition Procedures. Quotes must be submitted via email or fax and include the completed solicitation, lead time, and country of origin information.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SPMYM2-24-Q-2288 Amendment.pdf | ||
| EXHIBIT A-CDRL.pdf | ||
| EXHIBIT C-CDRL.pdf | ||
| SPMYM2-24-Q-2288.pdf | ||
| SPECIFICATION 24Q2288.pdf | ||
| EXHIBIT D-CDRL.pdf | ||
| EXHIBIT B- CDRL.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics for a Vacuum Recovery Unit Project #270-320
26 Jul 2024
1. Vacuum Recovery Unit (Industrial Vacuum Equipment Corporation, Hurricane Quiet Cube 150 HP, skid mounted vacuum, Item #QC-150, or equal. The Vacuum Recovery Unit shall be include the following minimal capabilities/features/items:
a. 460 Volt premium efficiency 150 horse power electrical motor, with all controls including soft starts in a NEMA 4 enclosure
b. Roots dresser Model #616DVJ, positive displacement, 2350 CFM capable of 27" of mercury, driven by 5 belts
c. 37 Teflon coated, sealed edge, quick change filter bags with 5 station reverse pulse cleaning and cyclonic separation. Air to cloth ratio 2.45:1
d. Sound attenuation system that keeps the total DBA at full vacuum, under 84 DBA, with no hearing protection required
e. Blower safety filter with a HEPA rating of 99.997 at .3 microns
f. Extra heavy duty 4" X 6" rectangular frame with fork lift pockets and certified lift eyes ( see paragraphs #4 & #5)
g. One (1) yard capacity collection cone mounted below the baghouse and cyclone separator; The cone shall have an automatic vibrator
h. Discharge of the vacuumed material will be automatic by adjustable timer. The discharge height will be 12" to 50" high, in 12" increments
i. 10" inspection manhole
j. Industrial epoxy primer base with high solids polyethylene top coat. One color, with logos
k. Flip top lid on baghouse
l. Gas shock on baghouse lid to assist with open and closing
m. OSHA approved work platform for filter bag change outs
n. Hydraulic lift baghouse/cyclone for a discharge height of 7 Feet
o. Magnehelic gauges on baghouse and blower safety filter
p. NRTL by UL Labs (see paragraph #2)
q. Operation & Maintenance Manuals (Qty: 2) (see paragraph #3)
r. A remote emergency tops button with 50 foot cord, quiet operation and locking shroud
s. One (1) year warranty on the entire vacuum, not including normal wear items (see paragraph #6)
2. Safety Requirement - The equipment and its component parts shall be in compliance with applicable Code of Federal Regulations (CFR) Title 29, Part 1910. By definition, any equipment will be deemed acceptable and approved by TRF, Bangor, if it meets specific Occupational Safety and Health Administration (OSHA) conditions outlined in CFR Title 29, Part 1910; Subparts "O" and "S". Specifically, equipment will be "Accepted" by TRF, Bangor, if it has been inspected and found by a Nationally Recognized Testing Laboratory (NRTL) to conform to specified plans or procedures of applicable codes. The equipment (as a whole system) shall be Nationally Recognized Testing Laboratory (NRTL) inspected and certified (by an OSHA authorized third party). Two (2) “hard” copies of the NRTL certification report shall be provided.
If the equipment type/model has already been NRTL inspected and certified, a certification report (two (2) ”hard” copies) or documentation mounted on the equipment, (which acknowledges it is NRTL certified), shall be provided.
3. Operator / Maintenance / Repair Manuals - The equipment shall be furnished with two (2) “hard” copies of the manufacturer’s standard Product Manual/Operation, Maintenance, and Repair Manual(s), bound in durable three ring binder(s). The manuals shall include all mechanical and electrical schematics showing discrete components/block diagrams/wiring diagrams with inputs and outputs identified/system electrical interface documents and drawings for the specific model of all machine equipment/drives/controls supplied. The information contained in the manual(s) shall reflect the unit and its components in the “as built” configuration. The information contained in the manual(s) shall be adequate to permit trouble shooting and repair of the equipment by journeymen level personnel. The information contained in the manual(s) shall be in the English language. The information contained in the manual(s) shall be in imperial units of measure.
4. Load Test of Crane Lifting Points/Padeyes and Non-Destructive Testing of the Attachment Welds - The contractor shall perform these tests prior to shipping the equipment to the government. Each lifting point/padeye shall undergo a load test for a minimum of 2 minutes without damage or deformation. The design & load test criteria, or Working Load Limit (WLL) for the lifting points/padeyes shall be per Process Instruction No. 611-400-026B, Appendix 1. Lift points/padeyes for 3 or 4 point lifts shall be sized such that any two points carry the entire load based on worse case load distribution with respect to the center of gravity. Acceptance shall be based on no visible damage or permanent deformation following the proof test. Damage and permanent deformation is defined as cracks, tears, mushrooming of load-bearing areas, bent or twisted padeyes or structure, etc. On each lifting padeye (or immediately adjacent to it) the crane lifting point/padeye rated capacity, 125% (+5%, -0%) test load and test date shall be stenciled or labeled in 1-inch high letters. All design load calculations shall be based on the “maximum weight” (+10%) including the additional loads induced by the lifting sling angle (and the weight of loaded fuel, etc.), per Process Instruction No. 611-400-026B, Appendix 1 (see paragraph 2.2).
OR
If the pull testing of the lifting padeyes are not performed, the engineering calculations (Performed by a Professional Engineer, P.E.), and the Magnetic Particle Testing (MT) certification papers of “each” padeye
5. Crane Lifting Point/Padeye Certification and Non-Destructive Testing (NDT) Report - Concurrent with delivery of the equipment, the contractor shall provide a signed, written certification of compliance to the lifting points/padeyes load test and NDT testing requirements as outlined in this specification. The lifting points/padeyes certification statement shall include that all lifting pads have been designed in accordance with design criteria of per Process Instruction (PI) for “Padeyes: Temporary and Permanent;
Installation, Use and Removal of” (PI No. 611-400-026B), for Trident Refit Facility, Bangor (TRF, Bangor). (A copy shall be provided by the government upon request), and that each lifting point/padeye has successfully passed a 125% to 130% load test. The NDT report shall show the results of the magnetic particle or liquid penetrant examination of each load bearing weld of the lifting point/padeye. Failure to provide the satisfactory load test certification and the NDT report could result in rejection of this equipment, because of failure to comply with the terms of the contract.
OR
If the pull testing of the lifting padeyes are not performed, the engineering calculations (Performed by a Professional Engineer, P.E.), and the Magnetic Particle Testing (MT) certification papers of “each” padeye
6. Warranty - Two (2) “hard” copies of the warranty certificate shall be provided. Supplies and services furnished shall be covered by warranty from defects in design, materials and workmanship. The warranty shall be the manufacturer’s standard commercial warranty, which shall conform to all the requirements of the contract. Acceptance of the manufacturer’s standard commercial warranty shall not minimize the rights of the government under clauses in the contract, and in any conflict that arises between the terms and conditions of the contract and manufacturer’s warranty, the terms and conditions of the contract shall take precedence. The warranty period shall be for 1 year. The warranty period shall commence from the date of acceptance. All warranty work shall be provided by a factory authorized distributer.
7. Admittance To The Work Site:
a. Upon contract award, employees or representatives of the Contractor who require access to the
Receiving Activity's facility at Naval Base Kitsap, Bangor (NBK, Bangor) shall be admitted to the work site only after they have been issued an appropriate Naval Region NW visitor security badge which is obtained at NBK, Bangor Pass & ID Office (located outside the NBK, Bangor Trident/ Main Gate).
b. Navy Region NW badge is required to gain access to Trident Refit Facility (TRF) Bangor Site, and is obtained through the “on-line” Base Authorization and Visit Request (BAVR) computer system. The prime contractor will need to submit all badge requests for their personnel and for sub-contractor personnel.
c. To request a Navy Region NW badge, (use Internet Explorer or Microsoft Edge browsers) and go on line to https://www.bavr.cnic.navy.mil. After the web site comes up, click “APPLY FOR NEW BADGE” button and submit a request for a badge, a minimum of five business days prior to arrival.
All requested information highlighted in red is mandatory. Type N/A for “Driver’s License Information”. The "Command you are visiting" is: Trident Refit Facility TRF). The “Company Name or Command” and “Work Phone” is your company/command information. The “Originating Command Security Officer Information” should be left blank. The "Sponsor E-Mail" for an on-line badge should be: aaron.k.peal1@navy.mil (Aaron Peal, 360-315-1047, 360-471-8624 (cell)). In the "Purpose of Visit" box, please explain in detail the purpose of your visit, and include the Contract Number, the Receiving Activity Point of Contact (name and telephone number) and ALL the buildings/areas/piers you are visiting. The “Start Date” is the day you expect to pick up your badge.
The “End Date” is the last date of your visit. Also send a copy of the contract to Aaron Peal at the e-mail address listed above. You will be notified at the e-mail address you provided, when all approvals have been completed. If the BAVR computer system doesn't work, try different search engines (“Firefox” search engine seems to work the best). If BAVR still doesn’t work contact the Receiving Activity Point of Contact or our security manager, Aaron Peal, 360-315-1047, 360-471- 8624 (cell) to schedule a visit(s), and shall provide the following information:
* Full Legal Name
* US Citizen Status
* All Company Contact Information
* Contract Number
d. Visitors must show proof of US Citizenship (at the NBK Bangor Pass & ID Office, located outside Bangor’s Main Gate (Trident Boulevard), with office hours: Monday – Friday, 7:00 am – 3:00 pm), by having an original active US Passport, OR an "Enhanced Driver's License" (from Washington, Vermont, Michigan, Minnesota or New York), OR an unlamented official birth certificate. “Real IDs” are not accepted.
e. Truck delivery personnel only need to show their Bill of Lading and show proof of US Citizenship (at the NBK Bangor Pass & ID Office) by having an original active US Passport, Enhanced Driver's License, or an unlamented official birth certificate. All deliveries must pass through the base Truck Inspection Station. All delivery vehicles are subject to inspection. Drivers should expect delays due to heightened security.
f. Notice: Persons who are currently on probation or parole from a felony conviction cannot qualify for security clearances, and will be denied access to the activity.
g. It shall be the Contractor's responsibility to collect, account for all identification passes issued to their personnel at the expiration of the contract or when access is no longer required. All NBK Bangor Pass & ID Office issued badges and identification passes must be returned back to the NBK Bangor Pass & ID Office no later than the expiration date. Badges can be dropped off at the NBK Bangor
Pass & ID Office, or drop box located at the Main Gate (Trident Boulevard), when exiting the base by vehicle (outside lane), or mailed back to the site POC.
h. Foreign Nationals or Affiliations - Foreign Nationals (non U.S. Citizens) or persons affiliated with, or employed by, a foreign, or foreign owned company will not be granted access without proper NBK Bangor Commanding Officer's written approval. Please note that All NBK Bangor Command Foreign Nationals or Affiliations visit request must be submitted sixty (60) days prior to a requested visit date.
i. Identification. All Contractors shall clearly identify themselves as contactor personnel. Badging shall be attached to the front side of clothing above the waist, or on a lanyard worn around the neck, hanging on the front side of clothing.
File details come from the government source that posted it. Updated .