AMENDMENT 0002 of SOLICITION SPMYM2-22-Q-2080.pdf

PDF 369 KB Posted

Attached to
DRUM
Solicitation number
SPMYM2-22-Q-2080
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N4523AIDIQDRUM

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

THE AMENDMENT IS BEING ISSUED TO CHANGE THE DECRIPTION OF THE CLIN 0003, 1003 & 2003 AND EXTEND THE CLOSING DATE TO

08/10/2022 AT 10 AM PACIFIC TIME.

THE OTHER TERMS AND CONDITIONS REMAIN UNCHANGED.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 08-Aug-2022

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X SPMYM222Q2080

X 9B. DATED (SEE ITEM 11)

15-Jun-2022

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

08-Aug-2022

CODE

DLA MARITIME PUGET SOUND

ATTN: KIM VO

467 W STREET

BREMERTON WA 98314

SPMYM2 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

SPMYM222Q2080

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 1449 - CONTINUATION SHEET

SOLICITATION/CONTRACT FORM

The required response date/time has changed from 01-Aug-2022 10:00 AM to 10-Aug-2022 10:00 AM.

SUPPLIES OR SERVICES AND PRICES

CLIN 0003

The CLIN extended description has changed from:

BASE YEAR5 GALLON CRIMPED TOPREMOVABLE LID WITH GASKETSTANDARD HEIGHT,

SLIGHTLY TAPERED SIDESBAIL HANDLESTEELCONSTRUCTION ,IAW 49 CFR, PART 178PAINTED

BLACKDRUMS LINED WITH RUST INHIBITORMUST BE CLEAN AND NEWEACH PAIL MUST BE

MARKED UN # 1A2 / Y36 / S (SOLIDS)PACKAGED 108 EACH PER PALLETA. DRUMS TO BE

MANUFACTURED TO MEET THE TESTING AND MARKINGREQUIREMENTS OF 49 CFR, SUBTITLE B,

CHAPTER 1, PART 178, SUBPART L (NON-BULK PERFORMANCE ORIENTED PACKAGING

STANDARDS )B. PACKING GROUP "Y" IS MINIMUM, "X" IS ALSO ACCEPTABLE.C. SPECIFIC

GRAVITY OF 1.5 IS MINIMUM.D. HYDROSTATIC PRESSURE OF 300 IS MINIMUM.E. MINIMUM

THICKNESS FOR STEEL IN BODY OF DRUM IS TO BE 20GAUGE.F. DRUMS ARE TO BE STANDARD

DIMENSIONS FOR 55 GALLONDRUMS AND PAINTED BLACK.G. TWO THREADED PLUG OPENINGS

(ONE EACH 2 INCH & 3/4 INCH) ON DRUM HEADSARE TO BE DIAMETRICALLY OPPOSED TO EACH OTHER, AND THREADEDPLUGS ARE TO BE IN PLACE.H. DRUMS TO BE PALLETIZED AND COVERED

WITH A FIBERBOARDCAP TO PRECLUDE STANDING WATER ON DRUM HEADS. PALLETS MAY

BEEITHER 40" X 48" OR 48" X 48" AND MUST ALLOW 4 WAY ENTRY.DRUMS TO BE SECURED TO

PALLETS TO PREVENT MOVEMENTAND/OR DAMAGE DURING SHIPMENT.

To:

BASE YEARDRUM, SHIPPING & STORAGE, CLOSED HEAD, USED FOR LIQUIDS 55 GL, WITH 2" & 3/4"

THREADED PLUG OPENINGS ON DRUM HEAD STEEL CONSTRUCTION, MFR IAW 49CFR PART 178

SUBPART L P/N: 1A1/Y1.5/300

CLIN 1003

FIRST YEAR5 GALLON CRIMPED TOPREMOVABLE LID WITH GASKETSTANDARD HEIGHT,

SLIGHTLY TAPERED SIDESBAIL HANDLESTEELCONSTRUCTION ,IAW 49 CFR, PART 178PAINTED

BLACKDRUMS LINED WITH RUST INHIBITORMUST BE CLEAN AND NEWEACH PAIL MUST BE

MARKED UN # 1A2 / Y36 / S (SOLIDS)PACKAGED 108 EACH PER PALLETA. DRUMS TO BE

MANUFACTURED TO MEET THE TESTING AND MARKINGREQUIREMENTS OF 49 CFR, SUBTITLE B,

CHAPTER 1, PART 178, SUBPART L (NON-BULK PERFORMANCE ORIENTED PACKAGING

STANDARDS )B. PACKING GROUP "Y" IS MINIMUM, "X" IS ALSO ACCEPTABLE.C. SPECIFIC

GRAVITY OF 1.5 IS MINIMUM.D. HYDROSTATIC PRESSURE OF 300 IS MINIMUM.E. MINIMUM

THICKNESS FOR STEEL IN BODY OF DRUM IS TO BE 20GAUGE.F. DRUMS ARE TO BE STANDARD

SPMYM222Q2080

DIMENSIONS FOR 55 GALLONDRUMS AND PAINTED BLACK.G. TWO THREADED PLUG OPENINGS

(ONE EACH 2 INCH & 3/4 INCH) ON DRUM HEADSARE TO BE DIAMETRICALLY OPPOSED TO EACH OTHER, AND THREADEDPLUGS ARE TO BE IN PLACE.H. DRUMS TO BE PALLETIZED AND COVERED

WITH A FIBERBOARDCAP TO PRECLUDE STANDING WATER ON DRUM HEADS. PALLETS MAY

FIRST YEARDRUM, SHIPPING & STORAGE, CLOSED HEAD, USED FOR LIQUIDS 55 GL, WITH 2" & 3/4"

THREADED PLUG OPENINGS ON DRUM HEAD STEEL CONSTRUCTION, MFR IAW 49CFR PART 178

SUBPART L P/N: 1A1/Y1.5/300

CLIN 2003

SECOND YEAR5 GALLON CRIMPED TOPREMOVABLE LID WITH GASKETSTANDARD HEIGHT,

SLIGHTLY TAPERED SIDESBAIL HANDLESTEELCONSTRUCTION ,IAW 49 CFR, PART 178PAINTED

BLACKDRUMS LINED WITH RUST INHIBITORMUST BE CLEAN AND NEWEACH PAIL MUST BE

MARKED UN # 1A2 / Y36 / S (SOLIDS)PACKAGED 108 EACH PER PALLETA. DRUMS TO BE

MANUFACTURED TO MEET THE TESTING AND MARKINGREQUIREMENTS OF 49 CFR, SUBTITLE B,

CHAPTER 1, PART 178, SUBPART L (NON-BULK PERFORMANCE ORIENTED PACKAGING

STANDARDS )B. PACKING GROUP "Y" IS MINIMUM, "X" IS ALSO ACCEPTABLE.C. SPECIFIC

GRAVITY OF 1.5 IS MINIMUM.D. HYDROSTATIC PRESSURE OF 300 IS MINIMUM.E. MINIMUM

THICKNESS FOR STEEL IN BODY OF DRUM IS TO BE 20GAUGE.F. DRUMS ARE TO BE STANDARD

DIMENSIONS FOR 55 GALLONDRUMS AND PAINTED BLACK.G. TWO THREADED PLUG OPENINGS

(ONE EACH 2 INCH & 3/4 INCH) ON DRUM HEADSARE TO BE DIAMETRICALLY OPPOSED TO EACH OTHER, AND THREADEDPLUGS ARE TO BE IN PLACE.H. DRUMS TO BE PALLETIZED AND COVERED

WITH A FIBERBOARDCAP TO PRECLUDE STANDING WATER ON DRUM HEADS. PALLETS MAY

SECOND YEARDRUM, SHIPPING & STORAGE, CLOSED HEAD, USED FOR LIQUIDS 55 GL, WITH 2" &

3/4" THREADED PLUG OPENINGS ON DRUM HEAD STEEL CONSTRUCTION, MFR IAW 49CFR PART

178 SUBPART L P/N: 1A1/Y1.5/300

(End of Summary of Changes)