SPMYM2-23-Q-1791 (SALIENT CHARACTERISTICS) SYSTEM HP WATERJET.pdf
PDF 420 KB Posted
- Attached to
- SYSTEM HP WATERJET Federal contract opportunity
- Solicitation number
- SPMYM2-23-Q-1791
About this file
This document outlines the technical specifications for a high pressure water jetting system solicited by the Defense Logistics Agency Land and Maritime under solicitation number SPMYM2-23-Q-1791. Key requirements for the system include a maximum pressure rating of 10,000 PSI, a flow rate of 6.1 GPM, manual pressure control, a rupture disc rated for 11,000 PSI, dimensions of approximately 48" tall x 45" wide x 34" deep to allow portability, NPT fittings for hoses and gauges, a standard motor control cabinet in place of a variable frequency drive, a 50HP motor rated for 480V 3-phase 60Hz power, and a 10 micron inlet filter.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SPMYM2-23-Q-1791 (SOLICITATION) SYSTEM HP WATERJET.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Doc #: 31863765
SALIENTS
High Pressure Water
Jetting System
-High Pressure Water Jetting System
* Rated for 10K PSI
* Rated for 6.1 GPM, with 0.63” Plungers
* Manual Pressure Control Valve
* Rupture Disc for 11K PSI (Relief Valve will suffice if Rupture Disc not feasible)
* Dimensions of the system to be approximately: 48” Tall x 45” Wide x 34” Deep to allow for being portable and allowing system to fit down into the engineering spaces of a Naval Vessel.
* Equipped for ½” NPT outlet for Aeroquip quick connects for Hoses along with Aeroquip quick connects for pressure gauge and relief valve.
* Standard Motor Control Cabinet (MCC) to be installed in lieu of the Variable Frequency Drive (VFD) and a Fused Knife Disconnect installed on the unit.
* 50HP AOL Starter, 380, 460VAC/3PH
* 10 Micron Filter installed on the water side.
* 50 HP Motor, 480V, 3 Phase, 60Hz, 59.2 Amp