SPK33014R5720_-_Make_Ready_Services.pdf

PDF 1 MB Posted

Attached to
Make Ready Services for U. S. Embassy, Islamabad, Pakistan Federal contract opportunity
Solicitation number
SPK33014R5720
Issued by
Department of State US Embassy Islamabad

View the file

Other files for this federal contract opportunity

Other files attached to Make Ready Services for U. S. Embassy, Islamabad, Pakistan, newest first.
File Type Posted
Attachement_(B).pdf PDF
Attachement_(A).pdf PDF
Amendment_A002.pdf PDF
Amendment_A001.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation # S-PK330-14-R-5720 0

Solicitation for make ready services.

September 6, 2014

To: Prospective Offerors

Subject: Solicitation number S-PK33014R5720, to provide make-ready services (Minor maintenance) for residences located in various sectors of Islamabad.

The Embassy of the United States of America invites you to submit a proposal for make-ready services

(minor maintenance and repair such as paint, air conditioning, plumbing, electrical, gardening etc.) for residences located in various sectors of Islamabad as described in Scope of Work (SOW).

If you are interested in submitting a proposal on this project, read the instructions in Section L of the attached

Request for Proposals (RFP) and submit your proposal, you should thoroughly examine all documents contained in the contract solicitation package. The Embassy intends to conduct a site visit. The site visit

(Pre-proposal conference) will be held on October 6, 2014 at 11:00 a.m. Offerors interested in attending must e-mail: LatifM@state.gov and ShahzadK2@state.gov on or before 2.00 p.m. October 1, 2014.

Maximum of two persons from one firm may participate in the site visit/ pre-proposal conference. Interested offerors must provide full name of participant(s) (as written on NIC), NIC number and particulars of vehicle to be used (make, model, color and registration number).

Your proposal must be submitted in a sealed envelope marked "Proposal Enclosed (SPK330-14-R-5720)" to GSO Procurement, American Embassy, Ramna-5, Islamabad on or before 1500 hrs on November 6, 2014, local time. No quotation will be accepted after this time.

Complete the OFFER portion of the Standard Form 1442, including all blank spaces, and have the form signed by an authorized representative of your company, or the proposal may be considered unacceptable and may be rejected.

In order for a Proposal to be considered:

follow the instructions in Section L of the solicitation, complete the required portions of the attached document, and submit your proposal to the address shown on the Standard Form 1442 that follows this letter.

The U.S. Government intends to award a contract to the responsible company submitting an acceptable offer at the lowest price. We intend to award a contract based on initial proposals, without holding discussions.

However, we may hold discussions with companies in the competitive range if there is a need to do so.

Sincerely, Faybein Moy

Contracting Officer

Enclosure: As Stated.

mailto:LatifM@state.gov mailto:ShahzadK2@state.gov

Solicitation # S-PK330-14-R-5720 1

OMB APPROVAL NO. 2700-0042

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

SPK33014R5720

2. TYPE OF SOLICITATION

SEALED BID

(IFB)

[x] NEGOTIATED

(RFQ)

3. DATE ISSUED

April 21, 2014

PAGE OF

PAGES

IMPORTANT - The “offer” section on the reverse must be fully completed by offeror.

4. CONTRACT NO.

5. REQUISITION/PURCHASE REQUEST NO.

PR2940894

6. PROJECT NO.

Make Ready services

7. ISSUED BY CODE 8. ADDRESS OFFER TO

Contracting Officer, GSO-Procurement & Contracting Office

American Embassy, Islamabad

Diplomatic Enclave, Ramna-5

Islamabad, Pakistan

Contracting Officer, GSO-Procurement & Contracting Office

American Embassy, Islamabad

Diplomatic Enclave, Ramna-5

Islamabad, Pakistan

9. FOR INFORMATION

CALL:

A. NAME

Mike M. Pitts

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

(92) 051-208-2218

SOLICITATION

NOTE: In sealed bid solicitations “offer” and “offeror” mean “bid” and “bidder.”

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS (Title, identifying no., date):

TABLE OF CONTENTS

A. Cover page, Standard Form 1442

B. Supplies or Services and Prices/costs

C. Description/Specifications/Work Statement

D. Packaging an Marking

E. Inspection and Acceptance

F. Deliveries or Performance

G. Contract Administration Data

H. Special Contract Requirements

I. Contract Clauses

J. List of Documents, Exhibits and other Attachments

K. Representations, Certifications, and other Statements of Offerors

L. Instructions, Conditions, and Notices to Offerors

Attachments/Exhibits

See list of exhibits in Section J

11. The Contractor shall begin performance within 3 calendar days and complete it within period specified in each task order after receiving award, notice to proceed. This performance period is mandatory, negotiable. (See _______________.)

12A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If “YES,” indicate within how many calendar days after award in Item 12B.)

YES NO

12B. CALENDAR DAYS

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and 2 copies to perform the work required are due at the place specified in Item 8 by 1500 (hour) local time

November 8, 2014. If this is a sealed bid solicitation, offers must be publicly opened at that time. Sealed envelopes containing offers shall be marked to show the offeror’s name and address, the solicitation number, and the date and time offers are due.

B. An offer guarantee is, is not required.

C. All offers are subject to the (1) work requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than 90 calendar days for Government acceptance after the date offers are due will not be considered and will be rejected.

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)

Computer Generated Prescribed by GSA

FAR (48 CFR) 53.236-1(e)

Solicitation # S-PK330-14-R-5720 2

Computer Generated STANDARD FORM 1442

BACK (REV. 4-85)

OFFER (Must be fully completed by offeror)

14. NAME AND ADDRESS OF OFFEROR (Include ZIP Code)

15. TELEPHONE NO. (Include area code)

16. REMITTANCE ADDRESS (Include only if different than Item 14)

CODE FACILITY CODE

17. The offeror agrees to perform the work at the prices specified below in strict accordance with the terms of this solicitation, if this offer is accepted by the Government within _____ calendar days after the date offers are due. (Insert any number equal to or greater than the minimum requirement stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.

AMOUNTS

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGMENT OF AMENDMENTS

The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN OFFER

(Type or print)

20B. SIGNATURE

20C. OFFER DATE

AWARD (To be completed by Government)

21. ITEMS ACCEPTED:

22. AMOUNT

23. ACCOUNTING AND APPROPRIATION DATA

24. SUBMIT INVOICES TO ADDRESS SHOWN IN

(4 copies unless otherwise specified)

ITEM

25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c)( ) 41 U.S.C. 253(c)( )

26. ADMINISTERED BY CODE GSO 27. PAYMENT WILL BE MADE BY

Contracting Officer, U.S Embassy, Diplomatic Enclave, Ramna-5

Islamabad

Islamabad, Pakistan

Financial Management Officer (FMO)

U.S Embassy, Diplomatic Enclave, Ramna-5

Islamabad

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

28. NEGOTIATED AGREEMENT (Contractor is required to sign this document and return ____ copies to issuing office.) Contractor agrees to furnish and deliver all items or perform all work, requisitions identified on this form and any continuation sheets for the consideration slated in this contract. The rights and obligations of the parties to this contract shall be governed by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certifications, and specifications or incorporated by reference in or attached to this contract.

29. AWARD (Contractor is not required to sign this document.)

Your offer on this solicitation is hereby accepted as to the items listed.

This award consummates the contract, which consists of (a) the Government solicitation and your offer, and (b) this contract award.

No further contractual document is necessary.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED

TO SIGN (Type or print)

31A. NAME OF CONTRACTING OFFICER (Type or print)

30B. SIGNATURE

30C. DATE 31B. UNITED STATES OF AMERICA

BY

31C. AWARD DATE

Solicitation # S-PK330-14-R-5720 2

SECTION B - SUPPLIES OR SERVICES AND PRICES/COSTS

B.1 SCOPE OF SERVICES

The Contractor shall provide personnel, supplies and equipment for all make-ready services for residences for U.S. Embassy, Islamabad as described in Sections B and

C of this contract, and the exhibits in Section J.

B.2 TYPE OF CONTRACT

This is an indefinite-delivery, indefinite-quantity type contract for make-ready.

The Contractor shall furnish services according to task orders issued by the Contracting

Officer. Oral task orders maybe necessary for emergencies, however, they shall be issued in writing within three days after issuance of the oral instructions. The task orders shall specify the location and type of work requested (see Section B.4 and the example in

Section J, Exhibit 2).

The contract will be for a one-year period from the date of the contract award, with 4 (four) one-year options. For each effective year of the contract, the U.S.

Government guarantees a minimum order of PKR 5,000,000 worth of services. The maximum amount of services ordered under each year of the contract will not exceed

PKR 120,000,000 worth of services.

B.3 PRICES/COSTS

The prices will include all work, including furnishing all labor, materials, equipment and services, unless otherwise specified in Section B.4.4. The prices listed below shall include all labor, materials, direct and indirect costs, insurance (see FAR 52.228-4 and

52.228-5), overhead, and profit.

B.3.1 VALUE ADDED TAX

Value Added Tax (VAT) is not applicable to this contract and shall not be included in the

CLIN rates or invoices because the U.S. Embassy has a tax exemption certificate from the host government.

B.3.2 CURRENCY

Pricing and Payment shall be made in the local currency (PKR); however, US firms may submit proposal for payment in US dollars.

Solicitation # S-PK330-14-R-5720 3

B.3.3 BASE YEAR PRICES (starting on the date stated in the Notice to Proceed and continuing for a period of 12 months)

CLIN Description of Service Unit of

Measure

Unit

Price

Estimated

Quantity

Total

Estimated

Price

Clean old paint, repair plaster, prime and smooth surface, apply ( two ) coats of ( emulsion) interior paint on walls and ceiling.

Square meter 5,000

Clean old paint, smooth surface, and apply ( two ) coats of ( emulsion) paint on walls and ceiling.

Square meter 10,000

Clean old paint, smooth surface, and apply ( one ) coats of ( emulsion) paint on walls and ceiling.

Square meter 5,000

Painting walls, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting ceilings, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting walls, two coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting ceilings, two coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting trim/baseboards, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Linear meter 5,000

Painting window grills, spikes and metal work, one coat, (oil-based) paint, (glossy) finish, following surface preparation. The grill is made of 1/2" square bar @ 6"x6" O.C.

Square meter 1,000

Painting of damaged surfaces (resin or plastic-based paint/Kitz or equal)

Square meter 1,000

Varnishing/shellacking of woodwork, following surface preparation

Square meter 1,000

12 Removal of wallpaper Square meter

Solicitation # S-PK330-14-R-5720 4

13 Textured Surfaces preparatory work Square meter 5,000

Painting of textured surfaces, one coat, (oil-based) paint, (glossy) finish

Square meter 5,000

Clean old paint, repair plaster, prime and smooth surface, apply ( two ) coats of weather shield paint on exterior of the house.

Square meter 10,000

Clean old paint, smooth surface, and apply (one) coats of weather shield paint on exterior of the house.

Square meter 10,000

Painting of textured surfaces, graphics (locally called rock wall) or similar on wall/façade surfaces -

Remove bubbled/loose graphics, clean and top dress related areas with the former color tone using brushes/rollers, then coat with same graphic material.

Square

10,000

17.1

Install new electrical water heater

(Embassy provided) with 6" high stand fabricated by 1-1/2"x1-1/2"

MS angle, black painted, 3 each valve(kitz grade-1) 3/4" size, 3 each union 3/4", all other accessories such as tees, elbow, barrel nipples, and pipe 3/4" about 10feet. Electrical connection from heater to main electrical panel approximate length

75feet 6mm cable Pakistan cable, dura duct, grounding wire, 30 Amp beaker for DB and earth leakage breaker exterior grade with cover near the heater. Provide galvanized iron sheet with angle iron bracing cover over heater. The cover shall be attached with wall and hang over the heater. Contractor will install

Temperature and Pressure relief

Valve (TPRV) and TPRV drain piping to direct discharge to floor.

The water heater exhaust must be located away from windows or intakes.

each 50

Solicitation # S-PK330-14-R-5720 5

17.2

Install new gas water heater

(Embassy provided) with all the fitting and accessories as per item

17.1 but excluding electrical work.

each 50

17.3

Install water filter (Embassy provided) on water pump supply line from underground to roof water tank.

each 150

17.4

Provide and install metal table

4’x2’x2’-6”, made of 1”x1” MS angle frame, 1 ½”x 1 ½” MS angle legs (4 each) with bracing of same size angle. Install MS sheet 18SWG sheet one at top and one at bottom, clean and paint two coat of paint including primer.

each 50

17.5

Provide and install small metal shed

(with 20SWG sheet, MS angle

1"x1"x1/8" angle frame and legs) over pressure pump and monoblock pump (approximate size 3'x3'x3' high).

each 50

Electrical services (see Section

C.2.6)

Square meter

18.1

Provide and install grounding rod

3/4" thick 8' feet long copper with

16mm thick ground wire up to main distribution panel and up to main disconnect switch approximate length of cable 30meter. Make sure the grounding works properly.

job 50

18.2

Replace old sockets and switches.

Provide and install SOKO/EURO type two with ground (Clipsal-

Australia) including box and repairs around.

each 500

18.3

Replace breakers. Provide and install breakers (Legrand) 20Amp in the panel.

each 100

18.4

Replace breakers. Provide and install breakers (Legrand) 16Amp in the panel.

each 150

18.5

Provide and install ground wires

2.5mm² (Pakistan cable) from sockets to sockets including dura each 10

Solicitation # S-PK330-14-R-5720 6 duct size 3/4". (approximate length

25feet)

18.6

Provide and install electric circuit with wire 4mm² (Pakistan cable) from main panel including ground wire to the required location in the room in existing conduit.

(approximate length 45feet) each 25

18.7

Provide and install electric circuit with wire 4mm² (Pakistan cable) from main panel to the required location in the room in including dura duct size 3/4". (approximate length 45feet) each 25

18.8

Provide and install electric circuit with wire 2.5mm² (Pakistan cable) from main panel to the master bedroom with connection box in including dura duct size 3/4".

(approximate length 45feet) each 25

18.9

Provide direct connection of pumps and electric water heater from GFCI breaker installed by Embassy.

each 25

18.10

Install GFCIs (Embassy provided)

10mA tripping, 16Amp sockets including wires.

each 100

18.11

Provide and install auto switch for water pumps and deep well pump.

(RADAR Liquid level control switch

ST-70ab. Made in Taiwan) each 25

18.12

Provide and install exhaust fan metal body 8" inch size with louvers (Pak

Fan), repairs holes etc.

each 25

18.13 Provide and install ceiling fan 56"

(Pak fan).

each 25

18.14

Replace old tube light. Provide and install Florescent light diffuser type.

Double rod 36W each, 4' long each 75

18.15

Replace old tube light. Provide and install Florescent light diffuser type.

Single rod 36W each, 4' long each 75

18.16

Replace old tube light. Provide and install Florescent light diffuser type.

Double rod 18W each, 2' long

Solicitation # S-PK330-14-R-5720 7

18.17

Replace old tube light. Provide and install Florescent light diffuser type.

Single rod 18W each, 2' long each 50

18.18

Provide and install FICO disconnect switch 100Amp on wall near ATS panel.

each 25

18.19

Mark all panels, distribution boards, circuit breakers, & outlets for correct label (English and Urdu) for identification and troubleshooting purposes.

Job 25

19 HVAC services (see Section C.2.7) Square meter 5,500

19.1

Service/repair existing air conditioning (split type) units.

(Electronic circuit/blower motor/fan motor) shall be provided by

Embassy).

each 100

19.2 Gas charging to air conditioning

(split type) units.

each 50

19.3

Provide and install metal tray (size

1'-6"x3') under outdoor units with outlet. Extend water outlet to the nearest drain. (approximate size of pipe 3/4" length 10 feet) each 80

19.4 Replace AC drain with new 3/4"

PVC pipe BETA exterior grade pipe.

each 50

19.5

Install air conditioning (split type) units. It includes the dismantling of existing unit if there is one. All plumbing work related to air conditioners shall be performed by the contractor by using standard quality material. All material required for air conditioners

(Refrigerant gas, insulation tape, aero flex pipes, duct tape, PVC pipe) shall be USA made and provided by contractor.

Batteries of AC shall be replaced only with good quality, and remotes shall be installed in proper places with screw. All air conditioner drains shall be channelized in pipes to each 80

Solicitation # S-PK330-14-R-5720 8 proper main holes. Pipes shall not be exposed on walk ways.

19.6 Provide and install remote control

batteries AAA Duracell each 160

Carpentry services (see Section

C.2.8)

Square meter 5,500

20.1

Provide and install weather strip 2" wide, 1/4" thick rubber on all exterior doors.

each 40

20.2

Provide and install lock on doors.

Lock shall be BAGATI 500, or

YANK knob lock, or AM

FAULTLESS high grade locks hand type.

each 50

20.3 Install lock on exit doors. (Embassy

shall provide lock).

each 40

20.4 Provide and install cabinets (kitchen

or closets). Lock shall be KG or 808.

each 40

20.5

Provide and install mesh screen of aluminum/wooden windows, repair latch and hinges

Square meter

20.6 Provide and install door stopper

(heavy duty, best quality) each 50

20.7

Provide and install door handles and hinges on cabinets and closets.

(heavy duty, best quality) each 50

20.8 Repairs of doors size 3'x7' each 20

20.9

Repairs doors that includes replacement of top plywood on both side 1/8" thick.

each 20

20.10 Provide and replace architrave for

doors and windows

Linear meter

20.11 Provide and replace base board

(wooden)

Linear meter

20.12

Provide and install windows blinds, aluminum (blinds shall be Butterfly blinds)

Square meter

20.13 Install door viewer on exterior doors

(Embassy shall provide door viewer) each 30

20.14 provide and install D-type curtain railing on all windows with double rod (aluminum) including fitting and accessories. Base shall be of deodar

Linear

Solicitation # S-PK330-14-R-5720 9 wood.

20.15

Provide and install drawers rail including accessories. The rail shall be best quality each 40

20.16 replace window glass 5mm thick clear or tinted glass including fitting.

Square meter

21 Roofing services (see Section C.2.9) Square meter 2,750

Gardening services (see Section

C.2.10)

Square meter 5,000

Masonry services (see Section

C.2.11)

Square meter 5,500

General Mechanical services (see

Section C.2.12)

Square meter 5,500

Safety Equipment services (see

Section C.2.13)

Square meter 5,500

25.1

Install smoke detectors on all bedrooms, corridors, servant quarters. (Embassy shall provide smoke detectors) each 100

25.2

Provide and install door bell

(dingdong) locally available. Bell push shall be near at the main entrance door.

Total of all line-items prices:

Base Year Total: ___________________

Solicitation # S-PK330-14-R-5720 10

B.3.4 FIRST OPTION YEAR PRICES

The Contractor shall provide the services shown below for Option Year 1, starting one year after the date stated in the Notice to Proceed and continuing for a period of 12 months. The fixed unit prices and estimated quantities for each category are:

Measure

Unit

Price

Estimated

Quantity

Total

Estimated

Price

Clean old paint, repair plaster, prime and smooth surface, apply ( two ) coats of ( emulsion) interior paint on walls and ceiling.

Square meter 5,000

Clean old paint, smooth surface, and apply ( two ) coats of ( emulsion) paint on walls and ceiling.

Square meter 10,000

Clean old paint, smooth surface, and apply ( one ) coats of ( emulsion) paint on walls and ceiling.

Square meter 5,000

Painting walls, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting ceilings, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting walls, two coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting ceilings, two coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting trim/baseboards, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Linear meter 5,000

Painting window grills, spikes and metal work, one coat, (oil-based) paint, (glossy) finish, following surface preparation. The grill is made of 1/2" square bar @ 6"x6" O.C.

Square meter 1,000

Painting of damaged surfaces (resin or plastic-based paint/Kitz or equal)

Square meter 1,000

Varnishing/shellacking of woodwork, following surface preparation

Square

1,000

Solicitation # S-PK330-14-R-5720 11

12 Removal of wallpaper Square meter

13 Textured Surfaces preparatory work Square meter 5,000

Painting of textured surfaces, one coat, (oil-based) paint, (glossy) finish

Square meter 5,000

Clean old paint, repair plaster, prime and smooth surface, apply (two ) coats of weather shield paint on exterior of the house.

Square meter 10,000

Clean old paint, smooth surface, and apply (one) coats of weather shield paint on exterior of the house.

Square meter 10,000

Painting of textured surfaces, graphics (locally called rock wall) or similar on wall/façade surfaces -

Remove bubbled/loose graphics, clean and top dress related areas with the former color tone using brushes/rollers, then coat with same graphic material.

Square meter 10,000

17.1

Install new electrical water heater

(Embassy provided) with 6" high stand fabricated by 1-1/2"x1-1/2"

MS angle, black painted, 3 each valve(Kitz grade-1) 3/4" size, 3 each union 3/4", all other accessories such as tees, elbow, barrel nipples, and pipe 3/4" about 10feet. Electrical connection from heater to main electrical panel approximate length

75feet 6mm cable Pakistan cable, dura duct, grounding wire, 30 Amp beaker for DB and earth leakage breaker exterior grade with cover near the heater. Provide galvanized iron sheet with angle iron bracing cover over heater. The cover shall be attached with wall and hang over the heater. Contractor will install

Temperature and Pressure relief

Valve (TPRV) and TPRV drain piping to direct discharge to floor.

The water heater exhaust must be located away from windows or

Solicitation # S-PK330-14-R-5720 12 intakes.

17.2

Install new gas water heater

(Embassy provided) with all the fitting and accessories as per item

17.1 but excluding electrical work.

each 50

17.3

Install water filter (Embassy provided) on water pump supply line from underground to roof water tank.

each 150

17.4

Provide and install metal table

4’x2’x2’-6”, made of 1”x1” MS angle frame, 1 ½”x 1 ½” MS angle legs (4 each) with bracing of same size angle. Install MS sheet 18SWG sheet one at top and one at bottom, clean and paint two coat of paint including primer.

each 50

17.5

Provide and install small metal shed

(with 20SWG sheet, MS angle

1"x1"x1/8" angle frame and legs) over pressure pump and monoblock pump (approximate size 3'x3'x3' high).

each 50

Electrical services (see Section

C.2.6)

Square meter

18.1

Provide and install grounding rod

3/4" thick 8' feet long copper with

16mm thick ground wire up to main distribution panel and up to main disconnect switch approximate length of cable 30meter. Make sure the grounding works properly.

job 50

18.2

Replace old sockets and switches.

Provide and install SOKO/EURO type two with ground (Clipsal-

Australia) including box and repairs around.

each 500

18.3

Replace breakers. Provide and install breakers (Legrand) 20Amp in the panel.

each 100

18.4

Replace breakers. Provide and install breakers (Legrand) 16Amp in the panel.

each 150

Solicitation # S-PK330-14-R-5720 13

18.5

Provide and install ground wires

2.5mm² (Pakistan cable) from sockets to sockets including dura duct size 3/4". (approximate length

25feet) each 10

18.6

Provide and install electric circuit with wire 4mm² (Pakistan cable) from main panel including ground wire to the required location in the room in existing conduit.

(approximate length 45feet) each 25

18.7

Provide and install electric circuit with wire 4mm² (Pakistan cable) from main panel to the required location in the room in including dura duct size 3/4". (approximate length 45feet) each 25

18.8

Provide and install electric circuit with wire 2.5mm² (Pakistan cable) from main panel to the master bedroom with connection box in including dura duct size 3/4".

(approximate length 45feet) each 25

18.9

Provide direct connection of pumps and electric water heater from GFCI breaker installed by Embassy.

each 25

18.10

Install GFCIs (Embassy provided)

10mA tripping, 16Amp sockets including wires.

each 100

18.11

Provide and install auto switch for water pumps and deep well pump.

(RADAR Liquid level control switch

ST-70ab. Made in Taiwan) each 25

18.12

Provide and install exhaust fan metal body 8" inch size with louvers (Pak

Fan), repairs holes etc.

each 25

18.13 Provide and install ceiling fan 56"

(Pak fan).

each 25

18.14

Replace old tube light. Provide and install Florescent light diffuser type.

Double rod 36W each, 4' long each 75

18.15

Replace old tube light. Provide and install Florescent light diffuser type.

Single rod 36W each, 4' long each 75

Solicitation # S-PK330-14-R-5720 14

18.16 install Florescent light diffuser type.

Double rod 18W each, 2' long each 50

18.17

Replace old tube light. Provide and install Florescent light diffuser type.

Single rod 18W each, 2' long each 50

18.18

Provide and install FICO disconnect switch 100Amp on wall near ATS panel.

each 25

18.19

Mark all panels, distribution boards, circuit breakers, & outlets for correct label (English and Urdu) for identification and troubleshooting purposes.

Job 25

19 HVAC services (see Section C.2.7) Square meter 5,500

19.1

Service/repair existing air conditioning (split type) units.

(Electronic circuit/blower motor/fan motor) shall be provided by

Embassy).

each 100

19.2 Gas charging to air conditioning

(split type) units.

each 50

19.3

Provide and install metal tray (size

1'-6"x3') under outdoor units with outlet. Extend water outlet to the nearest drain. (approximate size of pipe 3/4" length 10 feet) each 80

19.4 Replace AC drain with new 3/4"

PVC pipe BETA exterior grade pipe.

each 50

19.5

Install air conditioning (split type) units. It includes the dismantling of existing unit if there is one. All plumbing work related to air conditioners shall be performed by the contractor by using standard quality material. All material required for air conditioners

(Refrigerant gas, insulation tape, aero flex pipes, duct tape, PVC pipe) shall be USA made and provided by contractor.

Batteries of AC shall be replaced only with good quality, and remotes

Solicitation # S-PK330-14-R-5720 15 shall be installed in proper places with screw. All air conditioner drains shall be channelized in pipes to proper main holes. Pipes shall not be exposed on walk ways.

19.6 Provide and install remote control

batteries AAA Duracell each 160

Carpentry services (see Section

C.2.8)

Square meter 5,500

20.1

Provide and install weather strip 2" wide, 1/4" thick rubber on all exterior doors.

each 40

20.2

Provide and install lock on doors.

Lock shall be BAGATI 500, or

YANK knob lock, or AM

FAULTLESS high grade locks hand type.

each 50

20.3 Install lock on exit doors. (Embassy

shall provide lock).

each 40

20.4 Provide and install cabinets (kitchen

or closets). Lock shall be KG or 808.

each 40

20.5

Provide and install mesh screen of aluminum/wooden windows, repair latch and hinges

Square meter

20.6 Provide and install door stopper

(heavy duty, best quality) each 50

20.7

Provide and install door handles and hinges on cabinets and closets.

(heavy duty, best quality) each 50

20.8 Repairs of doors size 3'x7' each 20

20.9

Repairs doors that includes replacement of top plywood on both side 1/8" thick.

each 20

20.10 Provide and replace architrave for

doors and windows

Linear meter

20.11 Provide and replace base board

(wooden)

Linear meter

20.12

Provide and install windows blinds, aluminum (blinds shall be Butterfly blinds)

Square meter

20.13 Install door viewer on exterior doors

(Embassy shall provide door viewer) each 30

Solicitation # S-PK330-14-R-5720 16

20.14 provide and install D-type curtain railing on all windows with double rod (aluminum) including fitting and accessories. Base shall be of deodar wood.

Linear meter

20.15

Provide and install drawers rail including accessories. The rail shall be best quality each 40

20.16 replace window glass 5mm thick clear or tinted glass including fitting.

Square meter

21 Roofing services (see Section C.2.9) Square meter 2,750

Gardening services (see Section

C.2.10)

Square meter 5,000

Masonry services (see Section

C.2.11)

Square meter 5,500

General Mechanical services (see

Section C.2.12)

Square meter 5,500

Safety Equipment services (see

Section C.2.13)

Square meter 5,500

25.1

Install smoke detectors on all bedrooms, corridors, servant quarters. (Embassy shall provide smoke detectors) each 100

25.2

Provide and install door bell

(dingdong) locally available. Bell push shall be near at the main entrance door.

First Option Year Total: ____________________________

Solicitation # S-PK330-14-R-5720 17

B.3.5 SECOND OPTION YEAR PRICES

The Contractor shall provide the services shown below for Option Year 2, starting two years after the date stated in the Notice to Proceed and continuing for a period of 12 months. The fixed unit prices and estimated quantities for each category are:

Measure

Unit

Price

Estimate d Quantity

Total

Estimated

Price

Clean old paint, repair plaster, prime and smooth surface, apply ( two ) coats of ( emulsion) interior paint on walls and ceiling.

Square meter 5,000

Clean old paint, smooth surface, and apply ( two ) coats of ( emulsion) paint on walls and ceiling.

Square meter 10,000

Clean old paint, smooth surface, and apply ( one ) coats of ( emulsion) paint on walls and ceiling.

Square meter 5,000

Painting walls, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting ceilings, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting walls, two coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting ceilings, two coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting trim/baseboards, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Linear meter 5,000

Painting window grills, spikes and metal work, one coat, (oil-based) paint, (glossy) finish, following surface preparation. The grill is made of 1/2" square bar @ 6"x6"

O.C.

Square

Solicitation # S-PK330-14-R-5720 18

Painting of damaged surfaces (resin or plastic-based paint/Kitz or equal)

Square meter 1,000

Varnishing/shellacking of woodwork, following surface preparation

Square meter 1,000

12 Removal of wallpaper Square meter

13 Textured Surfaces preparatory work Square meter 5,000

Painting of textured surfaces, one coat, (oil-based) paint, (glossy) finish

Square meter 5,000

Clean old paint, repair plaster, prime and smooth surface, apply ( two) coats of weather shield paint on exterior of the house.

Square meter 10,000

Clean old paint, smooth surface, and apply (one) coats of weather shield paint on exterior of the house.

Square meter 10,000

Painting of textured surfaces, graphics (locally called rock wall) or similar on wall/façade surfaces -

Remove bubbled/loose graphics, clean and top dress related areas with the former color tone using brushes/rollers, then coat with same graphic material.

Square meter 10,000

17.1

Install new electrical water heater

(Embassy provided) with 6" high stand fabricated by 1-1/2"x1-1/2"

MS angle, black painted, 3 each valve(Kitz grade-1) 3/4" size, 3 each union 3/4", all other accessories such as tees, elbow, barrel nipples, and pipe 3/4" about

10feet. Electrical connection from heater to main electrical panel approximate length 75feet 6mm cable Pakistan cable, dura duct, grounding wire, 30 Amp beaker for

DB and earth leakage breaker exterior grade with cover near the heater. Provide galvanized iron

Solicitation # S-PK330-14-R-5720 19 sheet with angle iron bracing cover over heater. The cover shall be attached with wall and hang over the heater. Contractor will install

Temperature and Pressure relief

Valve (TPRV) and TPRV drain piping to direct discharge to floor.

The water heater exhaust must be located away from windows or intakes.

17.2

Install new gas water heater

(Embassy provided) with all the fitting and accessories as per item

17.1 but excluding electrical work.

each 50

17.3

Install water filter (Embassy provided) on water pump supply line from underground to roof water tank.

each 150

17.4

Provide and install metal table

4’x2’x2’-6”, made of 1”x1” MS angle frame, 1 ½”x 1 ½” MS angle legs (4 each) with bracing of same size angle. Install MS sheet 18SWG sheet one at top and one at bottom, clean and paint two coat of paint including primer.

each 50

17.5

Provide and install small metal shed

(with 20SWG sheet, MS angle

1"x1"x1/8" angle frame and legs) over pressure pump and monoblock pump (approximate size 3'x3'x3' high).

each 50

Electrical services (see Section

C.2.6)

Square meter

18.1

Provide and install grounding rod

3/4" thick 8' feet long copper with

16mm thick ground wire up to main distribution panel and up to main disconnect switch approximate length of cable 30meter. Make sure the grounding works properly.

job 50

18.2

Replace old sockets and switches.

Provide and install SOKO/EURO type two with ground (Clipsal-

Australia) including box and repairs each 500

Solicitation # S-PK330-14-R-5720 20 around.

18.3

Replace breakers. Provide and install breakers (Legrand) 20Amp in the panel.

each 100

18.4

Replace breakers. Provide and install breakers (Legrand) 16Amp in the panel.

each 150

18.5

Provide and install ground wires

2.5mm² (Pakistan cable) from sockets to sockets including dura duct size 3/4". (approximate length

25feet) each 10

18.6

Provide and install electric circuit with wire 4mm² (Pakistan cable) from main panel including ground wire to the required location in the room in existing conduit.

(approximate length 45feet) each 25

18.7

Provide and install electric circuit with wire 4mm² (Pakistan cable) from main panel to the required location in the room in including dura duct size 3/4". (approximate length 45feet) each 25

18.8

Provide and install electric circuit with wire 2.5mm² (Pakistan cable) from main panel to the master bedroom with connection box in including dura duct size 3/4".

(approximate length 45feet) each 25

18.9

Provide direct connection of pumps and electric water heater from

GFCI breaker installed by

Embassy.

each 25

18.10

Install GFCIs (Embassy provided)

10mA tripping, 16Amp sockets including wires.

each 100

18.11

Provide and install auto switch for water pumps and deep well pump.

(RADAR Liquid level control switch ST-70ab. Made in Taiwan) each 25

18.12

Provide and install exhaust fan metal body 8" inch size with louvers (Pak Fan), repairs holes etc.

each 25

Solicitation # S-PK330-14-R-5720 21

18.13 Provide and install ceiling fan 56"

(Pak fan).

each 25

18.14

Replace old tube light. Provide and install Florescent light diffuser type. Double rod 36W each, 4' long each 75

18.15

Replace old tube light. Provide and install Florescent light diffuser type. Single rod 36W each, 4' long each 75

18.16

Replace old tube light. Provide and install Florescent light diffuser type. Double rod 18W each, 2' long each 50

18.17

Replace old tube light. Provide and install Florescent light diffuser type. Single rod 18W each, 2' long each 50

18.18

Provide and install FICO disconnect switch 100Amp on wall near ATS panel.

each 25

18.19

Mark all panels, distribution boards, circuit breakers, & outlets for correct label (English and Urdu) for identification and troubleshooting purposes.

Job 25

19 HVAC services (see Section C.2.7) Square meter 5,500

19.1

Service/repair existing air conditioning (split type) units.

(Electronic circuit/blower motor/fan motor) shall be provided by Embassy).

each 100

19.2 Gas charging to air conditioning

(split type) units.

each 50

19.3

Provide and install metal tray (size

1'-6"x3') under outdoor units with outlet. Extend water outlet to the nearest drain. (approximate size of pipe 3/4" length 10 feet) each 80

19.4

Replace AC drain with new 3/4"

PVC pipe BETA exterior grade pipe.

Solicitation # S-PK330-14-R-5720 22

19.5

Install air conditioning (split type) units. It includes the dismantling of existing unit if there is one. All plumbing work related to air conditioners shall be performed by the contractor by using standard quality material. All material required for air conditioners

(Refrigerant gas, insulation tape, aero flex pipes, duct tape, PVC pipe) shall be USA made and provided by contractor.

Batteries of AC shall be replaced only with good quality, and remotes shall be installed in proper places with screw. All air conditioner drains shall be channelized in pipes to proper main holes. Pipes shall not be exposed on walk ways.

each 80

19.6 Provide and install remote control

batteries AAA Duracell each 160

Carpentry services (see Section

C.2.8)

Square meter 5,500

20.1

Provide and install weather strip 2" wide, 1/4" thick rubber on all exterior doors.

each 40

20.2

Provide and install lock on doors.

Lock shall be BAGATI 500, or

YANK knob lock, or AM

FAULTLESS high grade locks hand type.

each 50

20.3 Install lock on exit doors. (Embassy

shall provide lock).

each 40

20.4

Provide and install cabinets

(kitchen or closets). Lock shall be

KG or 808.

each 40

20.5

Provide and install mesh screen of aluminum/wooden windows, repair latch and hinges

Square meter

20.6 Provide and install door stopper

(heavy duty, best quality) each 50

20.7

Provide and install door handles and hinges on cabinets and closets.

(heavy duty, best quality)

Solicitation # S-PK330-14-R-5720 23

20.8 Repairs of doors size 3'x7' each 20

20.9

Repairs doors that includes replacement of top plywood on both side 1/8" thick.

each 20

20.10 Provide and replace architrave for

doors and windows

Linear meter

20.11 Provide and replace base board

(wooden)

Linear meter

20.12

Provide and install windows blinds, aluminum (blinds shall be Butterfly blinds)

Square meter

20.13

Install door viewer on exterior doors (Embassy shall provide door viewer) each 30

20.14 provide and install D-type curtain railing on all windows with double rod (aluminum) including fitting and accessories. Base shall be of deodar wood.

Linear meter

20.15

Provide and install drawers rail including accessories. The rail shall be best quality each 40

20.16 replace window glass 5mm thick clear or tinted glass including fitting.

Square meter

Roofing services (see Section

C.2.9)

Square meter 2,750

Gardening services (see Section

C.2.10)

Square meter 5,000

Masonry services (see Section

C.2.11)

Square meter 5,500

General Mechanical services (see

Section C.2.12)

Square meter 5,500

Safety Equipment services (see

Section C.2.13)

Square meter 5,500

25.1

Install smoke detectors on all bedrooms, corridors, servant quarters. (Embassy shall provide smoke detectors) each 100

25.2

Provide and install door bell

(dingdong) locally available. Bell push shall be near at the main entrance door.

Solicitation # S-PK330-14-R-5720 24

Second Option Year Total: ____________________________

B.3.6 THIRD OPTION YEAR PRICES

The Contractor shall provide the services shown below for Option Year 3, starting three years after the date stated in the Notice to Proceed and continuing for a period of 12 months. The fixed unit prices and estimated quantities for each category are:

Measure

Unit

Price

Estimated Quantity

Total

Estimated

Price

Clean old paint, repair plaster, prime and smooth surface, apply ( two ) coats of ( emulsion) interior paint on walls and ceiling.

Square meter 5,000

Clean old paint, smooth surface, and apply ( two ) coats of ( emulsion) paint on walls and ceiling.

Square meter 10,000

Clean old paint, smooth surface, and apply ( one ) coats of ( emulsion) paint on walls and ceiling.

Square meter 5,000

Painting walls, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting ceilings, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting walls, two coat, (oil-based) paint, (glossy) finish, following surface preparation

Square meter 1,000

Painting ceilings, two coat, (oil-based) paint, (glossy) finish, following surface preparation

Square

Solicitation # S-PK330-14-R-5720 25

Painting trim/baseboards, one coat, (oil-based) paint, (glossy) finish, following surface preparation

Linear meter 5,000

Painting window grills, spikes and metal work, one coat, (oil-based) paint, (glossy) finish, following surface preparation. The grill is made of 1/2" square bar @ 6"x6"

O.C.

Square meter 1,000

Painting of damaged surfaces (resin or plastic-based paint/Kitz or equal)

Square meter 1,000

Varnishing/shellacking of woodwork, following surface preparation

Square meter 1,000

12 Removal of wallpaper Square meter

13 Textured Surfaces preparatory work Square meter 5,000

Painting of textured surfaces, one coat, (oil-based) paint, (glossy) finish

Square meter 5,000

Clean old paint, repair plaster, prime and smooth surface, apply ( two ) coats of weather shield paint on exterior of the house.

Square meter 10,000

Clean old paint, smooth surface, and apply (one) coats of weather shield paint on exterior of the house.

Square meter 10,000

Painting of textured surfaces, graphics (locally called rock wall) or similar on wall/façade surfaces -

Remove bubbled/loose graphics, clean and top dress related areas with the former color tone using brushes/rollers, then coat with same graphic material.

Square

Solicitation # S-PK330-14-R-5720 26

17.1

Install new electrical water heater

(Embassy provided) with 6" high stand fabricated by 1-1/2"x1-1/2"

MS angle, black painted, 3 each valve(Kitz grade-1) 3/4" size, 3 each union 3/4", all other accessories such as tees, elbow, barrel nipples, and pipe 3/4" about

10feet. Electrical connection from heater to main electrical panel approximate length 75feet 6mm cable Pakistan cable, dura duct, grounding wire, 30 Amp beaker for

DB and earth leakage breaker exterior grade with cover near the heater. Provide galvanized iron sheet with angle iron bracing cover over heater. The cover shall be attached with wall and hang over the heater. Contractor will install

Temperature and Pressure relief

Valve (TPRV) and TPRV drain piping to direct discharge to floor.

The water heater exhaust must be located away from windows or intakes.

each 50

17.2

Install new gas water heater

(Embassy provided) with all the fitting and accessories as per item

17.1 but excluding electrical work.

each 50

17.3

Install water filter (Embassy provided) on water pump supply line from underground to roof water tank.

each 150

17.4

Provide and install metal table

4’x2’x2’-6”, made of 1”x1” MS angle frame, 1 ½”x 1 ½” MS angle legs (4 each) with bracing of same size angle. Install MS sheet 18SWG sheet one at top and one at bottom, clean and paint two coat of paint including primer.

Solicitation # S-PK330-14-R-5720 27

17.5

Provide and install small metal shed

(with 20SWG sheet, MS angle

1"x1"x1/8" angle frame and legs) over pressure pump and monoblock pump (approximate size 3'x3'x3' high).

each 50

Electrical services (see Section

C.2.6)

Square meter

18.1

Provide and install grounding rod

3/4" thick 8' feet long copper with

16mm thick ground wire up to main distribution panel and up to main disconnect switch approximate length of cable 30meter. Make sure the grounding works properly.

job 50

18.2

Replace old sockets and switches.

Provide and install SOKO/EURO type two with ground (Clipsal-

Australia) including box and repairs around.

each 500

18.3

Replace breakers. Provide and install breakers (Legrand) 20Amp in the panel.

each 100

18.4

Replace breakers. Provide and install breakers (Legrand) 16Amp in the panel.

each 150

18.5

Provide and install ground wires

2.5mm² (Pakistan cable) from sockets to sockets including dura duct size 3/4". (approximate length

25feet) each 10

18.6

Provide and install electric circuit with wire 4mm² (Pakistan cable) from main panel including ground wire to the required location in the room in existing conduit.

(approximate length 45feet) each 25

18.7

Provide and install electric circuit with wire 4mm² (Pakistan cable) from main panel to the required location in the room in including dura duct size 3/4". (approximate length 45feet) each 25

Solicitation # S-PK330-14-R-5720 28

18.8

Provide and install electric circuit with wire 2.5mm² (Pakistan cable) from main panel to the master bedroom with connection box in including dura duct size 3/4".

(approximate length 45feet) each 25

18.9

Provide direct connection of pumps and electric water heater from

GFCI breaker installed by

Embassy.

each 25

18.10

Install GFCIs (Embassy provided)

10mA tripping, 16Amp sockets including wires.

each 100

18.11

Provide and install auto switch for water pumps and deep well pump.

(RADAR Liquid level control switch ST-70ab. Made in Taiwan) each 25

18.12

Provide and install exhaust fan metal body 8" inch size with louvers (Pak Fan), repairs holes etc.

each 25

18.13 Provide and install ceiling fan 56"

(Pak fan).

each 25

18.14

Replace old tube light. Provide and install Florescent light diffuser type. Double rod 36W each, 4' long each 75

18.15

Replace old tube light. Provide and install Florescent light diffuser type. Single rod 36W each, 4' long each 75

18.16

Replace old tube light. Provide and install Florescent light diffuser type. Double rod 18W each, 2' long each 50

18.17

Replace old tube light. Provide and install Florescent light diffuser type. Single rod 18W each, 2' long each 50

18.18

Provide and install FICO disconnect switch 100Amp on wall near ATS panel.

each 25

18.19

Mark all panels, distribution boards, circuit breakers, & outlets for correct label (English and Urdu) for identification and troubleshooting purposes.

Job 25

19 HVAC services (see Section C.2.7) Square

5,500

Solicitation # S-PK330-14-R-5720 29

19.1

Service/repair existing air conditioning (split type) units.

(Electronic circuit/blower motor/fan motor) shall be provided by Embassy).

each 100

19.2 Gas charging to air conditioning

(split type) units.

each 50

19.3

Provide and install metal tray (size

1'-6"x3') under outdoor units with outlet. Extend water outlet to the nearest drain. (approximate size of pipe 3/4" length 10 feet) each 80

19.4

Replace AC drain with new 3/4"

PVC pipe BETA exterior grade pipe.

each 50

19.5

Install air conditioning (split type) units. It includes the dismantling of existing unit if there is one. All plumbing work related to air conditioners shall be performed by the contractor by using standard quality material. All material required for air conditioners

(Refrigerant gas, insulation tape, aero flex pipes, duct tape, PVC pipe) shall be USA made and provided by contractor.

Batteries of AC shall be replaced only with good quality, and remotes shall be installed in proper places with screw. All air conditioner drains shall be channelized in pipes to proper main holes. Pipes shall not be exposed on walk ways.

each 80

19.6 Provide and install remote control

batteries AAA Duracell each 160

Carpentry services (see Section

C.2.8)

Square meter 5,500

20.1

Provide and install weather strip 2" wide, 1/4" thick rubber on all exterior doors.

each 40

20.2

Provide and install lock on doors.

Lock shall be BAGATI 500, or

YANK knob lock, or AM

FAULTLESS high grade locks

Solicitation # S-PK330-14-R-5720 30 hand type.

20.3 Install lock on exit doors. (Embassy

shall provide lock).

each 40

20.4

Provide and install cabinets

(kitchen or closets). Lock shall be

KG or 808.

each 40

20.5

Provide and install mesh screen of aluminum/wooden windows, repair latch and hinges

Square meter

20.6 Provide and install door stopper

(heavy duty, best quality) each 50

20.7

Provide and install door handles and hinges on cabinets and closets.

(heavy duty, best quality) each 50

20.8 Repairs of doors size 3'x7' each 20

20.9

Repairs doors that includes replacement of top plywood on both side 1/8" thick.

each 20

20.10 Provide and replace architrave for

doors and windows

Linear meter

20.11 Provide and replace base board

(wooden)

Linear meter

20.12

Provide and install windows blinds, aluminum (blinds shall be Butterfly blinds)

Square meter

20.13

Install door viewer on exterior doors (Embassy shall provide door viewer) each 30

20.14 provide and install D-type curtain railing on all windows with double rod (aluminum) including fitting and accessories. Base shall be of deodar wood.

Linear meter

20.15

Provide and install drawers rail including accessories. The rail shall be best quality each 40

20.16 replace window glass 5mm thick clear or tinted glass including fitting.

Square meter

Roofing services (see Section

C.2.9)

Square

2,750

Solicitation # S-PK330-14-R-5720 31

Gardening services (see Section

C.2.10)

Square meter 5,000

Masonry services (see Section

C.2.11)

Square meter 5,500

General Mechanical services (see

Section C.2.12)

Square meter 5,500

Safety Equipment services (see

Section C.2.13)

Square meter 5,500

25.1

Install smoke detectors on all bedrooms, corridors, servant quarters. (Embassy shall provide smoke detectors) each 100

25.2

Provide and install door bell

(dingdong) locally available. Bell push shall be near at the main entrance door.

Third Option Year Total: _________________________

B.3.7 FOURTH OPION YEAR PRICES

The Contractor shall provide the services shown below for Option Year 4, starting four years after the date stated in the Notice to Proceed and continuing for a period of 12 months. The fixed unit prices and estimated quantities for each category are:

Measu…