This document contains Salient Characteristics for three Radio Frequency (RF) Transmission Lines and Cable Assemblies, detailing technical specifications for specialized military-grade communication equipment. The three products are:
-
Part Number 914049: A Flexible RF Transmission Line with 7/8" diameter coaxial design, operating from Direct Current to 2.0 GHz, rated for -65 to 100 degrees C, with a maximum voltage of 6200V and RF power rating of 10KW peak. The cable features a copper alloy outer conductor, OFHC copper inner conductor, and a polychloroprene black jacket, designed to withstand 50,000 flexing cycles per foot.
-
Part Number 914051: A Semi-Rigid Cable Assembly with 7/8" flexible corrugated outer conductor, terminated with flange connectors, operating from Direct Current to 7.0 GHz. It has similar temperature and voltage specifications to the previous item, with a stranded silver-plated copper center conductor, polytetrafluoroethylene dielectric, and cadmium-plated flanges. The cable is designed for 50,000 flexing cycles and 100-pound cable retention.
-
Part Number 707473-2: A 3/8" Semi-Rigid Cable Assembly with a more expansive frequency range (Direct Current to 13.5 GHz), featuring a solid copper silver-plated center conductor, Teflon jacket, and unique termination with a flange, 7/8" bullet, and 5/8" collar. This cable boasts an impressive one million flex cycle capability and is designed for high-performance RF applications with specific mechanical and electrical requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation - N0016425Q0813.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Nomenclature: Line, RF Transmission, Flexible
Part Number: 914049
Voltage: 6200 V Max
Operating Temperature: -65 – 100 degrees C
Weight: Approx. 1-3 pounds
Dimensions: 13.12 L, .885 max Dia., Description: Transmission Line, RF, 7/8 Dia coaxial, Frequency Range: Direct Current to 2.0 GHz minimum, VSWR: 1.15:1 max. Input and outport, with load terminated in a VSWR of 1.05:1 max, measured at 1.0 GHz. Impedance: 50 OHMS, RF Power Rating: 10KW peak. Bend radius: 5.13 inches max.
Material: Outer Conductor and Flanges: Copper Alloy per ATSM B372 or equiv. Inner Conductor: OFHC Copper per ASTM B372 or equiv.
Finish: Outer Conductor Jacket: Polychoroprene, Black, per MIL-I-23053/1. Inner Conductor: Silver Plated per QQ-S-365 or equiv. Flanges: Cadmium Plated per QQ-P-416, Type II, Class 3. Flexible Life:
50,000 cycles per foot min as +- 45 degree bend.
Marking: Manufacturer’s name and Part Number, and Raytheon Part Number 914049-1, preceded by code indent no. 49956.
Nomenclature: Cable Assembly, Radio Frequency
Part Number: 914051
Operating Temperature: -65 – 100 degrees C
Weight: Approx. 3-5 pounds
Dimensions: 115 L, 1.15 Dia max
Description: Cable Assembly, Radio Frequency, Semi-Rigid, Corrugated Copper Alloy, 7/8 Inch, Jacketed.
Assembly shall consist of 7/8 inch flexible corrugated out conductor, jacketed, coaxial cable, with spline type dielectric, terminated with flange type connectors on each end.
Construction: Center Conductor: Stranded Copper, Silver Plated. Dielectric: Polytetrafluoroethylene.
Outer Conductor: Corrugated, Copper Alloy. Jacket: polychloroprene, Black, per MIL-I-23053/1. Max Diameter: 1.025 unjacketed, 1.150 with jacket. Flanges: Rotating Type: Per Requirements of MIL-F- 24044/2-01. Inner Conductor per MIL-F-24044/2-01C. Flange Finish: Cadmium Plated per QQ-P-416, Type II, Class 3, with all exterior surfaces painted per paragraph 1.2 Class I & II of 709244.
Mechanical Requirements: Flex-Life: Flexing +- 45 degrees per foot for a min of 50,000 cycles Cable Retention: 100 pounds min. Bend Radius: 5.13 min.
Electrical Requirements: Operating Frequency Range: Direct Current to 7.0 GHz. Impedance: 50 +- 2 OHMS. Operating Voltage: 6200 V max. Insertion Loss: 2.0 DB max per 100 feet at 1.0 GHz. RF Leakage:
100 DB min. VSWR: 1.15:1 max at 1.0 GHz
Environmental Requirements: Shock: Per MIL-STD-202, method 213, Condition A. Vibration: Per MIL- STD-202, Method 204, Condition A. Salt Spray: Per MIL-STD-202, Method 101, Condition B.
Marking: Marked or identified with manufacturers name and part number and Ratheon Part Number 914051-1, preceded by code indent no 49956.
Nomenclature: Cable Assembly, Radio Frequency
Part Number: 707473-2
Operating Temperature: -65 – 100 degrees C
Weight: Approx. 3-5 pounds
Dimensions: 52.09 L, .75 Dia max
Description: Cable Assembly, Radio Frequency, Semi-rigid, corrugated Copper Alloy, 3/8 Inch, jacketed.
Assembly shall consist of 3/8 inch flexible corrugated outer conductor, Teflon jacketed, coaxial cable, with spline type dielectric, terminated with flange and 7/8 inch bullet on one end and 5/8 diameter collar for split nut compression fitting on the opposite end.
Cable Construction: Center Conductor: 0.133 diameter solid copper silver plated. Dielectric:
Polytetrafluoroethylene. Outer Conductor: 0.475 max dia corrugated coppery alloy. Jacket: 0.510 max dia, polytetrafluoroethylene. Color Clear, flame resistant, nonburning. Bullet: Beryllium copper, silver plated. Flange: Aluminum or brass, cadmium plated, type II, Class 3 per QQ-P-416. Collar and Probe:
Brass, electrp;ess nickle plated per MIL-C-26074B, Class 2, Grade A
Mechanical: Flex-life: Shall be capable of flexing +- 45 degrees per foot for a min of one million cycles without degradation of mechanical or electrical performance. Cable retention: 100 pounds min. Tube Test: the collar and probe end of the cable shall pass freely through a tube of ID 0.635 inches by 5.5 inches long.
Electrical Requirements: Operating Frequency Range: Direct Current to 13.5 GHz. Impedance: 50 +- 2 OHMS. Operating Voltage: 2500 V. Capacitance: 25 Picofarads/foot. Insertion Loss: 6 DB per 100 feet at 1 GHz. RF Leakage: 100 DB. VSWR: Shall meet requirements of 707483 Note 3.
Environmental Requirements: Shock: PER MIL-STD-202, Method 213 Condition A. Vibration: Per MIL- STD-202, Method 204, Condition A. Salt Spray: Per MIL-STD-202, Method 101, Condition B
Identification: Identify part per MIL-STD-103 with manufacturers name and part number.