5/20/2008

SPECIFICATIONS FOR 150 MCM SHOF SHORE POWER CABLES

DESCRIPTION OF CABLE:

A. 150,000 MCM EXTRA FLEXIBLE, STRANDED, SINGLE CONDUCTOR;

B. #30 AWG NOT TINNED COPPER; APPROX. 760 STRANDS, STRAND CONSTRUCTION; 19 BY 40.

C. BUTYL OR ETHYLENE PROPYLENE RUBBER INSULATOR

D. TWO LAYER JACKET WITH THE LAYERS BONDED TOGETHER. INSULATION, MINIMUM .070" THICK, 90( C OPERATING TEMPERATURE; 2 REVERSED NYLON BRAID; INNER SEPARATOR;

SMOOTH, ABRASION-RESISTANT CURED-IN-LEAD OR POLYCURE

NEOPRENE JACKET, MINIMUM .075" THICK; 600 VOLT; JACKET TO BE IMPRINTED WITH MANUFACTURER'S NAME, SIZE, VOLTAGE, AND DATE;

E. OVERALL O. D. – .830 min, .870 max.

F. BEND RADIUS IN INCHES – 7.0" MIN.

G. ENDS OF CABLES WILL BE SEALED TO PREVENT DAMPNESS/WATER INTRUSION DURING SHIPPING AND STORAGE.

H. MINIMUM RESISTANCE RATINGS:

a. INSULATION RESISTANCE – 200 MEGOHMS PER 1000 FT

b. CONDUCTOR RESISTANCE – .0747 OHMS PER 1000 FT

I. 1000' SHIPPING LENGTHS ON REELS