Specifications Tensiometer.pdf

PDF 120 KB Posted

Attached to
Increased Sustainability and Utilization of Cotton and Other Natural Fiber-Based Textiles and Commercial Goods
Solicitation number
RFQ_1157400
Issued by

About this file

This document contains detailed technical specifications for a Theta Flow Optical Tensiometer used in scientific research. The device offers multiple experimental measurement capabilities, including static and dynamic contact angle measurements, surface/interfacial tension analysis, topography profiles, and surface free energy calculations using various scientific methods. Key technical specifications include a CMOS 1" USB 3.0 digital camera with 5MP resolution, maximum measuring speed of 3422 fps, and an integrated touch display.

The tensiometer requires a computer with a 2 GHz processor, 2 GB RAM, 120 GB hard drive (SSD recommended), and Windows 10 operating system. It operates within specific environmental conditions: ambient temperature of 15-30°C, pressure of 700-1060 hPa, and humidity of 20-80% non-condensing. The device has integrated sensors for monitoring temperature, humidity, and system levelness, and uses OneAttension software that includes all measurement modes. Physical specifications include dimensions of 765 x 230 x 435 mm, weight of 29 kg, and input voltage range of 100-240 VAC.

View the file

Other files

File Type Posted
NDAA 889 Certification.pdf PDF
USDA NDAA 889 Certification Form 2020.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifications for Theta Flow Optical Tensiometer with required parts for research:

Specifications:

Available measurements

Experiments available: Static contact angle, advancing and receding contact angles, batch contact angle, meniscus contact angle, surface / interfacial tension by pendant drop method, topography profiles, surface free energy and dilatational interfacial rheology by oscillating drop method.

Surface free energy methods: Zisman Plot, OWRK/Extended Fowkes, van Oss Acid-Base, Wu, Neumann’s Eq. of State, Schultz 1 and 2

Software and hardware

Measuring range (°, mN/m): 0…180, 0.01…2000

Accuracy (°, mN/m): ± 0.1, ± 0.01

Maximum sample size (mm): Unlimited x 100 x 320 (w. stage).

Integrated sample holders: Yes

Maximum resolution (pixels): 2592 x 2048 (5MP)

Maximum measuring speed (fps): 3422

Camera: CMOS 1’’ USB 3.0 digital camera with zoom.

Image focusing: Software-controlled autofocus, manual fine focus in optics

Image quality: Enhanced with DropletPlus technology

Camera protection: Inside instrument covers

Camera view angle (°): -4…2.5, with digital scale

Light source and size: High power monochromatic LED, 62 x 62 mm.

Field of view (diagonal in mm): 1.44…45.3

Measurement indicator LED: Yes

Integrated touch display Yes

Environment monitoring: Integrated digital ambient temperature, relative humidity and system levelness sensors

Disposable tip dispensing: Yes

Software: OneAttension, includes all measurement modes

Dimensions – Basic frame (LxWxH, mm): 765 x 230 x 435

Weight – Basic frame (kg): 29

Input voltage (Vac): 100…240

Frequency (Hz): 50…60

Input current (mA): 330…650

Fuses: T1.0A 5x20 mm

System requirements

Recommended system requirements for Theta Flow: 2 GHz processor, 2 GB RAM, 120 GB hard disk drive*, 1920x1080 resolution, 1 USB 3.0 port

*SDD hard disk (min. 500MB/s) needed for high speed recording with high resolution.

Operating system requirements: Windows 10 (32 or 64 bit).

Environmental conditions

Ambient temperature (°C): 15…30

Ambient pressure (hPa): 700…1060

Ambient humidity (%): 20-80 (non-condensing)