Specifications - Powerhouse Bathroom.pdf
PDF 931 KB Posted
- Attached to
- Construct Powerhouse Bathroom
- Solicitation number
- 15B50526PR000263
- Issued by
-
Department of Justice Bureau of Prisons
About this file
This is a Material Purchase solicitation for supplies and materials to construct a prefabricated single-use restroom for the Federal Bureau of Prisons (FBOP), Federal Medical Center (FMC) Carswell in Fort Worth, Texas (Project 24Z5AT3). The document outlines specifications for an 8' x 8' x 8' exterior restroom unit to be delivered and assembled on-site.
The specifications require Class A exterior walls rated for 115 mph wind loads with 3-inch thick composite sandwich panels, 32 linear feet of wall at 8 feet tall, and ½-inch OSB for fixture mounting. The unit must conform to ADA Standards with accessible control booths featuring service windows no higher than 34 inches, 32-inch minimum door openings, 60-inch clear turning spacing, and work surface heights between 27-34 inches. Wall insulation must be one-pound density polystyrene core with shear strength of 18-22 PSI and shear modulus of 280-320 PSI, with water absorption less than 4 percent. The exterior roof is specified as ½:12 pitch with 3-inch composite sandwich panels and stucco-embossed aluminum pre-painted surfaces, covering 102 square feet. The supplier must provide a 20-gauge insulated steel flush door (36"W x 84"H x 1 3/4" thick) with galvanized steel construction, channels, and hardware compliant with ANSI A1567. Plumbing includes one white china toilet with tank and seat, one white china lavatory sink with dual-control chrome-plated faucet, and installation kits for connection to existing rough plumbing. Electrical specifications include surface-mounted #12 gauge copper wiring, pre-wired receptacles and switches, one wall switch, one duplex receptacle, exterior LED fixtures, and ceiling-mounted 110-volt 2x4 LED light fixtures with 50,000-hour service life and 70% lumen maintenance. The electrical service requires a 125 AMP single-phase 120/240 volt load center. All supplies and materials must be submitted with complete product detail sheets and specifications. Delivery is available between 7:30 AM and 2:30 PM, Monday through Friday, excluding federal holidays. Reference drawings (Sheets A1-A5) provide location site plans, proposed site and floor plans, slab layout and section, and project photos.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Source Sought Questionnaire Construct Powerhouse Bathroom - SAM.gov.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .