Specifications - minirhizotron system.pdf
PDF 254 KB Posted
- Attached to
- Minirhizotron Imaging System Federal contract opportunity
- Solicitation number
- 12405B24Q0313
About this file
The document provided is a specification for a Minirhizotron Imaging System required by the USDA-ARS in Raleigh, NC. The key details are:
The imaging module must have a minimum scanning depth of 1.8 m, a minimum image resolution of 1200 dpi, weigh less than 5 lbs, and have a scan head diameter less than 2". The module must interface with a tablet or computer via USB and be USB-powered. The soil tubes must be a minimum of 1.8 m length and no greater than 2.25" outside diameter. The tablet or computer included must be NDAA-899 compliant.
This specification is related to a federal contract opportunity with Solicitation Number 12405B24Q0313 for the procurement of the Minirhizotron Imaging System. Offerors must submit a quote on company letterhead and a completed FAR 52.212-3 Offeror Representations and Certifications by 4:00PM CST on July 18, 2024. Award will be made based on best value to the government, with technical capability and past performance being more important than price.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Clauses and Provisions (supply Solicitation).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIFICATIONS
1.0 Specifications Description: Minirhizotron Imaging System
With soil tubes to facilitate soybean root research
Quantity: 1
Unit Type: Each
Minimum Requirements:
• The imaging module must have a minimum scanning depth of 1.8 m.
• The image resolution shall be a minimum of 1200 dpi.
• The weight of the imaging module shall be less than 5 lbs.
• The scan head shall have a diameter of less than 2”.
• The imaging module must interface with the in-field image viewer (tablet or computer) via
USB port.
• The imaging module must be powered via USB port connected to tablet or computer
• The soil tubes shall be a minimum of 1.8 m length and no greater than 2.25” outside diameter.
• Tablet or computer included with system must be NDAA-899 compliant.
2.0 Place of Delivery
USDA-ARS
Attn: Anna Locke 840 Oval Drive Raleigh, NC 27606
3.0 Delivery Schedule
Item QTY Unit Place of Delivery Delivery Date Minirhizotron imaging system 1 Each See section 2.0 mailto:anna.locke@usda.gov