This is a specifications document for RFQ 26-P-00127 issued by the City of Tampa's Wastewater Department in Florida for the procurement of fuel polishing equipment. The equipment must be delivered to the department's warehouse located at 2700 MaritimeBlvd, Tampa, FL 33605 between 7am and 3pm. The specifications detail a single unit of fuel polishing equipment with a chassis construction of steel and aluminum featuring Brite Tread, a maximum lift height of 15 feet, and a maximum working pressure of 40 PSI for fuel. The equipment must include a positive displacement pump with internal bypass, a maximum flow rate of 1,320 gallons per hour, and a two-gallon water trap capacity. Power specifications require 115/230V single-phase, 50/60Hz operation with a 3/4 horsepower TEFC motor.
The equipment specifications include dimensional requirements of 30 inches wide, 37 inches deep, and 50 inches overall height when primed. The unit must be equipped with 1-1/2 inch and 1 inch Cam-Loc inlets and outlets with ball valves, a 2-inch liquid-filled vacuum gauge, 24-inch bag sludge filters, a military-type micro-glass water coalescer, a Teflon hydrophobic water separator, and 13-inch flat-free wheels. Supply and return hoses must each measure 1-1/2 inches and 1 inch diameter respectively, both 12 feet in length. No pricing terms, set-asides, response deadlines, or award information is provided in the specifications document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Fuel_Polishing_Equipment.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifications for RFQ 26-P-00127 Fuel Polishing Equipment
Chassis Construction Steel and Aluminum Brite Tread
Maximum lift 15 feet primed
Working pressure fuel max. 40 PSI
Maximum Flow rate 1320 Gallons per hour
Water Trap two (2) Gallons US
Power 115/230V 1PH 50/60Hz 3/4HP TEFC
Width: 30” Depth: 37” Overall Height 50”
Pump positive displacement, with internal bypass
Inlets/Outlets 1-1/2” & 1” Cam-Loc w/ Ball Valves
Hose Supply 1-1/2” & Return 1” X 12’ each
Vacuum Gauge 2” liquid filled
Sludge Filters 24” Bag
Water Coalescer micro-glass (military type)
Water Separator Teflon hydrophobic
Wheels 13” flat free