SPECIFICATIONS FOR 250 MCM SINGLE CONDUCTOR, HEAT RESISTANT, OIL RESISTANT, FLEXIBLE (SHOF) SHORE POWER CABLES Lasted updated 12/27/2018
DESCRIPTION OF CABLE
1. 252.7 MCM extra flexible, stranded, single conductor
2. Cable characteristics: 90 degree Celsius operating temperature, 600V minimum rated, overall outside minimum 1.035” and maximum diameter 1.085”, Bend radius in inches – 8.5” minimum. Insulator and outer jacket bonded together.
2a. Conductor: #27 AWG not tinned copper; strand construction, approximately 1,254 strands 2b. Separator: Opaque Mylar 2c. Insulator: Butyl or Ethylene propylene rubber, minimum 0.070” thick 2d. Polyester Reinforcement Serve 2e. Outer Jacket: Smooth, abrasion-resistant polycure neoprene jacket, minimum 0.070” thick. Outer jacket to be imprinted with manufacturer’s name. size, voltage, and manufactured date
3. Ends of cables will be sealed to prevent dampness/water intrusion during shipping and storage.
4. Minimum resistance rating:
a. Insulation resistance – 150 Megohms per 1,000’
b. Conductor resistance - 0.0453 OHMs per 1000’
5. Ship lengths in 500’ to 1,000’ reels. Reel size approximately 40 to 45” in diameter by 27” plus/minus 1”. Cable length on spool must be divisible by 100’ (i.e. 590’ cable on a 500’ reel will be credited as a 500’ reel)