This document is a specification for 20-foot used shipping containers (Conex containers) for the Pennsylvania Department of Transportation (PennDOT). The procurement involves acquiring eight total 20-foot containers to be distributed across three PennDOT locations: four containers delivered to the Eighty Four garage, two containers to the Clover Hill shed, and two containers to the West Brownsville shed. The containers must meet specific quality standards, including being wind and watertight, with minimal rust, dents, and floor damage. Bidders are required to submit proposals electronically through the Commonwealth's electronic system (SRM) via the PA Supplier Portal, with technical support available through the Supplier Service Center.

The specification includes detailed technical requirements for the used shipping containers, such as intact door seals, floor conditions, door functionality, and hardware performance. Delivery must be accomplished using a tilt bed truck, with containers positioned facing the cab. Notably, bidders must complete the Worker Protection and Investment Certification Form (BOP-2201) to demonstrate compliance with Pennsylvania labor and workforce safety laws. The site contact for this procurement is Bonnie Cunningham, reachable at 724-223-4480, who can provide additional information about the container specifications and delivery requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifications for 20ft Used Conex shipping containers

All quantities are estimated.

WORKER PROTECTION - Pursuant to Executive Order 2021-06, Worker Protection and Investment (October 21, 2021), the Commonwealth is responsible for ensuring that every Pennsylvania worker has a safe and healthy work environment, and the protections afforded them through labor laws. To that end, contractors and grantees of the Commonwealth must certify that they are in compliance with all applicable Pennsylvania state labor and workforce safety laws. Such certification shall be made through the Worker Protection and Investment Certification Form (BOP-2201) and submitted with the bid, proposal, or quote.

Please complete and attach the BOP-2201 Worker Protection Form to your bid.

The container must be wind & watertight All rust is hammer-tested prior to delivery. Rusty pinholes and thinning steel are repaired with an overlay patch, extending beyond the affected area. Scratches and Dents should not exceed 4 inches inward or outward.

The seals must be intact The door seal gaskets secure the wind and watertightness of the moving door parts of the shipping container. The door gaskets will show no daylight from the interior of the container outward. The retainer strip holding the door gaskets will be intact and secured.

The floor is intact and in good condition All container floors must be inspected to ensure they are intact, providing a secure environment for storing goods. Flooring will not be broken or show holes, especially through to the undercarriage. Delamination may be present but will not exceed multiple layers. The floor should not be flexing or "spongy. “Holes and excessive delamination must be repaired with a wooden or steel plate. Crossmembers must be checked in conjunction with flooring. No broken welds should be present, and the crossmember should remain flush with the flooring.

The doors on the container open & close The doors to be able to be fully opened and peeled back. Container doors are heavier; however, they should open without maximum effort involved.

The door hardware has no malfunctions To close and lock the container from outside elements The lock rods to be able to rotate open and close, to lock or unlock the latch.

Door Opening: End wall doors are required. Side wall doors optional.

Easy open-door design and locking box which is typically only found on new units or the standard (4) locking bars will work.

Delivered to:

4 qty- 20 ft Conex containers PENNDOT Garage 160 SR 519, Eighty Four PA, 15330

2 qty- 20 ft Conex containers PENNDOT Clover Hill Shed 25 Grange Road, Coal Center PA 15423

2 qty- 20 ft Conex containers PENNDOT West Brownsville Shed 1 PennDOT Rd, Brownsville PA 15417

All containers need to face the cab of the delivery truck. Delivery needs to be with a tilt bed.

Site contact: Bonnie Cunningham RPC- 724-223-4480