Specifications - Drager CMS Analyzer Emergency Response Kit to include CMS Analyzer.docx
DOCX document 13 KB Posted
- Attached to
- Drager CMS Analyzer Emergency Response Kit
- Solicitation number
- RFQ - 15A - 13103000000000000326
- Issued by
- Maine
About this file
This is a specifications document for the State of Maine detailing requirements for a Drager CMS Analyzer Emergency Response Kit. The procurement seeks a complete system including the CMS Analyzer unit and all necessary components for emergency response applications. The specifications outline the required technical capabilities, performance standards, and operational features that the equipment must meet to support Maine's emergency response operations. The document establishes detailed functional requirements and acceptance criteria for the analyzer system, ensuring compatibility with existing emergency response protocols and infrastructure.
The specifications document includes technical performance parameters, certification requirements, and quality assurance standards that bidders must satisfy. The requirements address equipment calibration, reliability, maintenance protocols, and documentation standards necessary for operational deployment. Specific attention is given to interoperability requirements and data management capabilities essential for emergency response coordination. The document establishes baseline specifications to ensure all submitted bids meet Maine's operational needs and equipment standards for this critical emergency response procurement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Terms Conditions and Instructions to Bidders rev 1-25-12[1].doc | DOC document | |
| How to submit a response.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Drager CMS Analyzer Emergency Response Kit to include CMS Analyzer, 10 Chips (ammonia 10.0-150 ppm, carbon dioxide 1,000-25,000 ppm, carbon monoxide 5.0-150 ppm, chlorine 0.20-10.0 ppm, hydrochloric acid 1.0-25.0 ppm, hydrogen sulfide 2.0-50.0 ppm, nitrous fumes 0.20-15.0 ppm, perchloroethylene 5.0-500 ppm, petroleum hydrocarbons 100-3000 ppm, sulfur dioxide 0.40-10.0 ppm), remote system, telescopic probe, 4 spare batteries, pelican case and custom foam, laminated instructions and manuals, and space for 6 additional chips.