Specifications.docx
DOCX document 17 KB Posted
- Solicitation number
- 142082-26-0409
About this file
This is a technical specification document for electromagnetic field strength measurement equipment required under a NOAA solicitation for the Engineering Branch in Norman, Oklahoma. The specification outlines two line items (CLINs) totaling sixty units of radiation detection equipment.
CLIN 0001 specifies thirty Wavecontrol SMP3-Broadband meters (part number WSL0001 or equivalent) capable of measuring electric field strength in V/m and power density in mW/cm² across a frequency range of 50MHz-3GHz, with measurements ranging from 800V/m down to 1V/m or less. The meters must feature true RMS readings, timed averaging, peak/max hold functions, real-time display readout, and a handheld form factor operable with a single hand. Battery operation must support at least one hour of continuous use with rechargeable batteries, and units must be supplied with hardshell shipping cases. CLIN 0002 specifies thirty Wavecontrol WPF3-HP field probes (part number WWP0302 or equivalent) capable of withstanding peak fields of at least 12kV/m (tested at 1-second bursts) and continuous wave fields of at least 1kV/m, with frequency coverage of 50MHz-3GHz and compatibility with the specified meter. Award will be made on a firm fixed price basis to the responsive responsible quoter providing best value. All contractors must be registered in the System for Award Management (SAM) with a valid Unique Entity Identifier (UEI) prior to award.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1305M226Q0147.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
High Power Electromagnetic Field Strength Meter
TECHNICAL SPECIFICATION:
1.0 CLIN 0001: Total quantity thirty (30) Wavecontrol SMP3- Broadband meter part number WSL0001 or equivalent.
1.1 Specification:
Measurement Electric field strength in V/m
Power density in mW/cm2 or equivalent units
Range from 800V/m or greater to 1 V/m or lesser
True RMS Readings
Timed Averaging Function
Peak/Max Hold Function
Display with real-time readout
Frequency range must cover at least 50MHz-3GHz
Compatible with probe to be delivered with EMF Strength meter
Form Factor Handheld: Meter with probe attached must be reasonably useable in a single hand
Meter must be able to operate for at least one (1) hour from battery power alone
Batteries shall be rechargeable
Supplied with hardshell shipping case for unit and probe
2.0 CLIN 0002: Total quantity thirty (30) Wavecontrol WPF3-HP field Probe part number WWP0302 or equivalent
2.1 Specifications
Withstand fields of at least 12kV/m peak (peak is considered as tested at 1µs bursts)
Withstand continuous wave fields of at least 1kV/m
Frequency range must cover at least 50MHz-3GHz
Compatible with EMF Strength Meter to be delivered with probe
File details come from the government source that posted it. Updated .