This document outlines specifications for a low pressure injection molding machine solicitation by the Naval Air Warfare Center, Weapons Division in China Lake, California. The solicitation seeks a machine with horizontal injection and air over cylinder clamping capabilities producing a minimum clamping force of 5 tons and stroke of 150mm. The machine should accommodate molds up to 10" x 10" x 5.5" with safety features including a light curtain, emergency stop, and two hand door interlocks. Additional requirements include external melt tanks with 7 liter minimum capacity, 3 temperature control zones, a mobile base, touch screen controls, integrated ejection and chiller systems, and on-site equipment setup and training. Interested parties should respond to the solicitation number N6893624Q0055 by emailing Gwynn Hartkopf at gwynn.l.hartkopf.civ@us.navy.mil by the anticipated posting date of March 18, 2024 on the Contract Opportunities website. Offerors must maintain an active SAM registration and DLIS certification to access controlled information.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Commercial Solicitation N6893624Q0055.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Low pressure injection molding machine specifications A machine whose primary function is to over-mold cable connectors and circuit board assemblies
· Injection method – Horizontal
· Clamping method – Air over cylinder
· Clamping force – minimum 5 tons
· Clamping stroke - minimum 150 mm
· Mold size – minimum 10” X 10” X 5.5”
· Safety features – light curtain, emergency stop, two hand tie door interlocks
· Melt tanks – 2 external, 7 liter minimum capacity
· Temperature control zones – 3 minimum
· Mobile base/casters
· Touch screen controls
· Integrated ejection system
· Integrated chiller
· On site equipment setup and training