The Government is requesting the following items. Please submit a quote with the following items or a comparable system that meets or exceeds the salient characteristics listed in “General Requirements” section listed below.

1 each - CX300; Communications Service Monitor

1 each - CX300-AANT1; Antenna Kit 1 GHz

2 each - CX300-ABAT; Internal Battery 98 Watt-Hour Lithium-ion

1 each - CX300-ACBL; RF Cable

1 each - CX300-ACH; Carrying Case Hard Transit

General Requirements Proposed unit shall meet or exceed all requirements listed below:

Be portable and possess swappable batteries.

At minimum have - RF input, output and Duplex ports N-type and BNC connections.

Ability to save reports/test results and readings locally Trigger Inputs and Outputs for RADAR functionality

Component Requirements:

Spectrum Analyzer Auto Test for radios Oscilloscope Vector Network Analyzer Frequency Counter Power Meter RF Generator Analog Modulation Generator RF Receiver RF Demodulation Meter Audio Distortion/SINAD/S/N/AF Counter/level/ Meter Audio Analyzer AF Generator

Technical Requirements:

Range - 100 kHz to 3GHz Covers Radios and RADAR

VSWR

RF Duplex Port <1.1 (1 MHz to 1 GHz); <1.2 (1 GHz to 6 GHz) RF Output Port <1.4 (1 MHz to 1 GHz); <1.5 (1 GHz to 6 GHz)

Modulation:

Modes AM, FM, PM, SSB

Frequency:

Range 20 Hz to 20 kHz Distortion <1% THD

Internal Modulation Sources - number of sources 3

Measurement Modes RMS, average RMS, minimum, maximum

Bandwidth 5 kHz, 6.25 kHz, 8.33 kHz, 10 kHz, 12.5 kHz, 25 kHz, 30 kHz, 100 kHz, and 300 kHz

RF Receiver with a range of 9kHz to 3GHz Input level - +27 dBm (500 mW) max preamp and frequency >1 MHz +13 dBm (20 mW) max preamp on or frequency <1 MHz

Power Meter with a range of 100 kHz to 3 GHz -60dbm to +51dbm

Distortion Meter range AM 10 Hz to 20kHz

Spectrum Analyzer Frequency Range 9 kHz to 3 GHz RBW Range 100 Hz to 6 MHz VBW Range 100 Hz to 5 MHz Sweep Time Range 0.4 ms to 1000 s Display Range 1 dB/div to 20 dB/div with 10 divisions.

Trigger Free run, external.

Audio Level Meter with an input Impedance 100 kOhms, 600 Ohms

Oscilloscope 2 traces minimum Horizontal sweep at 20 micro secs to 1 second/division Vertical with a bandwidth of 100kHz Trigger Modes - single, normal, automatic, Free Run

Vector Network Analyzer with a range of 1 MHz to 6GHz Resolution - 0.1 Hz Measurement Displayed - Return Loss, VSWR Format - dB, VSWR