This document is a Specification for the fabrication and delivery of insulated glass units for the U.S. Bureau of Reclamation's Central California Area Office (CCAO) Pavilion project located at 7794 Folsom Dam Road, Folsom, California.

The requirement calls for the contractor to fabricate and deliver eight (8) insulated glass units sized to fit the truss openings at both ends of a PEQUEA 24' x 50' timber pavilion frame. Each unit must meet the following specifications: fully tempered insulated glass construction with ¼" Low-E 355 glass over ¼" clear glass, totaling 1 inch overall thickness. The contractor is required to field-verify all dimensions prior to fabrication, as the provided drawings are general and approximate. Final fabrication dimensions must be based on verified field measurements, with ½ inch clearance provided on all edges between glazing units and existing timber framing to allow for natural expansion, structural movement, and settling. The completed insulated glass units must be delivered to the Central California Area Office at the project location within 30 days after receipt of order. The specification includes reference drawings (BU-2 24x50 Kingston 5-Bents Drawings) and a photograph of the pavilion front view for reference purposes.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CCAO Pavilion Insulated Glass Folsom, California

Specifications

CCAO Pavilion Insulated Glass

SPECIFICATIONS

1. PROJECT DESCRIPTION

The U.S. Bureau of Reclamation, Central California Area Office (CCAO), purchased and assembled a PEQUEA 24’ x 50’ Timber Pavilion Frame. The insulated glass units procured under this requirement will be installed by Government personnel.

Location of Pavilion:

7794 Folsom Dam Road Folsom, CA 95630

2. REQUIREMENT

The Contractor shall fabricate and deliver insulated glass units that meet the specifications below.

2.1 Quantity

Eight (8) insulated glass units sized to fit the truss openings at both ends of the pavilion.

2.2 Dimensional Requirements

• Contractor shall field verify all dimensions prior to fabrication.

• Drawings provided are general and approximate. Final fabrication dimensions must be based on verified field measurements.

• Provide ½ inch clearance on all edges between glazing units and existing timber framing to allow for natural expansion, structural movement, and settling.

2.3 Product Specifications

Each insulated glass unit shall meet the following minimum requirements:

• Fully tempered insulated glass

• ¼” Low‑E 355 over ¼” clear

• 1 inch overall thickness

2.4 Deliverables

Completed insulated glass units fabricated to verified dimensions Delivery to:

Central California Area Office

7794 Folsom Dam Road Folsom, CA 95630

3. ATTACHMENTS

3.1 DRAWINGS

BU-2 24x50 Kingston 5-Bents Drawings

24’-0”

Pavilion Drawing: The above front view drawing of the pavilion contains approximate dimensions. The shown front view truss openings match rear view truss openings. Contractor to field verify units prior to fabrication.

3.2 PHOTOGRAPHS

Photograph A: Pavilion Front View (for reference only)

4. DELIVERY SCHEDULE

All items shall be delivered within 30 days after receipt of order.