This specification sheet details the resurfacing requirements for Pembroke Lakes Pool, located at 10500 Taft Street in Pembroke Pines, Florida, as issued by the City of Pembroke Pines. The project encompasses comprehensive pool restoration work including draining and hydrostatic pressure relief, removal of loose plaster and damaged sections, acid washing and surface preparation, application of Bond Kote sealant, installation of slip-resistant bull nose tile on pool steps and waterline per Florida Health Department regulations, replacement of broken coping and gutter tiles with chemical-resistant grout, replacement of faded or broken depth markers and no diving tiles, and application of Diamond Brite or Florida Gem pool coating in a color to be determined by the city with acid or water washing to expose color aggregate. Additional requirements include installation of new Virginia Graeme Baker Act-compliant main drain frames and grates supplied by the city, setup of a charcoal filtration system to prevent staining of the new surface, complete chemical balancing to Health Department standards, and restoration of the pool deck and surrounding areas to pre-work condition.

All installations must comply with local codes and Florida Health Department regulations, with inspections to be performed by the City of Pembroke Pines. The contractor is responsible for obtaining all required permits and associated costs. The specification sheet does not include information regarding pricing terms, contract duration, award dates, bidder meetings, site visits, response deadlines, or funding amounts and sources.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specification Sheet for resurfacing Pembroke Lakes Pool Location: 10500 Taft Street, Pembroke Pines, Fl 33026 Contractors Responsibilities:

1. Drain swimming pools and relieve hydrostatic pressure, if necessary.

2. Hand chip, chisel and remove all loose plaster. If necessary, cut out and repair where reinforcing steel is coming through. Under-cut and hand chisel below tile, around returns and other fixtures as required. Cut and repair all cracks.

3. Acid wash pool interior thoroughly from the coping line down to the clean etched surface to insure Proper adhesion of new surface to old. Neutralize acid wash.

4. Apply Bond Kote to pool interior in accordance with manufacturer recommendations.

5. Install new slip resistant bull nose tile on facing of steps and water line as per Florida Health Department regulations. Re-grout all new tiles with Chemical resistant grout. Tile should match current pool tile color.

6. Replace any broken tile on coping and gutter tile. Re-grout all new tiles with chemical resistant grout.

7. Replace faded or broken No Diving and depth marker tile.

8. Apply Diamond Brite/Florida Gem to pool interior, color and type to be determined by the City of Pembroke Pines. This product is to be batch mixed and hand troweled to a smooth and even finish. Then it is to be Acid Washed and/ or Water Washed to expose color aggregate. Tile breaks to be replaced with new tile.

9. Install new Virginia Graeme Baker Act Pool Compliant main drain frames and grates - supplied by the City of Pembroke Pines.

10. To prevent staining of the new Diamond Brite a special water purification system (charcoal filter tanks) must be set up.

11. Completely balance new pool water with all necessary chemicals, including stabilizer, which will bring water up to Health Department standards.

12. Pool deck and surrounding areas must left in the same condition as before work started.

13. Include all permit costs. Inspections to be determined by The City of Pembroke Pines.

All Installations must be made in accordance with local codes governing such installations.