This is a Specification Sheet for commercially available pressure transducers required by the Government in a quantity of 54 units. The transducers must be designed to measure hydrogen pressure within a range of 25-2200 psi and operate in absolute or sealed gage modes. The devices shall withstand over-pressure conditions of 2x rated pressure and burst pressures up to 5x rated pressure with a maximum limit of 15,000 psi.
The equipment specifications include an electrical excitation rating of 8 to 32 VDC with a maximum current of 25 mA, full scale output of 4.0 VDC +/- 0.25 VDC, and total error band of +/- 0.25% FSO maximum. Additional performance requirements encompass an operating temperature range of -40°F to +265°F, compensated temperature range of -40°F to +250°F, linear vibration tolerance of 20g peak sine wave (10 to 2000 Hz), and mechanical shock resistance of 20g half-sine wave with 11-millisecond duration. The transducers must feature 100% relative humidity tolerance, infinitesimal resolution, insulation resistance of 100 megohms at 50 VDC, and output impedance of 750 megohm maximum. Physical specifications include a weight of 110 grams, pressure sensing principle utilizing a fully active four-arm Wheatstone bridge with dielectrically isolated silicon on silicon, mounting torque limit of 100 inch-pounds maximum, electrical connection via PTIH-10-6P connector or equivalent, and pressure port connection of 7/16-20UNJF-3A MS33656E-4. The requirement can be satisfied by Kulite manufacturer part number BME-76-1100 or an equivalent commercially available product.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Cover Page_Pressure Transducers.pdf | ||
| Solicitation - FA910126QB050.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specification Sheet
The Government requires commercially available equipment meeting the specifications provided below.
Pressure Transducer Quantity: 54
Specification Value
Media Hydrogen
Pressure Range 25-2200 psi
Operational Mode Absolute, Sealed Gage
Over Pressure 2x Rated Pressure
Burst Pressure 5x Rated Pressure to 15,000 psi Maximum
Rated Electrical Excitation 8 to 32 VDC
Maximum Current 25 mA (Maximum)
Insulation Resistance 100 Megohms @ 50 VDC
Output Impedance 750 Megohm Max
Full Scale Output (Net) 4.0 VDC +/- .25 VDC
Total Error Band (Excluding End Points) +/- .25% FSO Max. (Combined Non-Linearity, Hysteresis, Repeatability, and All Thermal Effects Included)
Resolution Infinitesimal
Operating Temperature Range -40 deg F to +265 deg F (-40 deg C to +130 deg C)
Compensated Temperature Range -40 deg F to +250 deg F (-40 deg C to +120 deg C)
Linear Vibration 20g Peak, Sine 10 to 2000 Hz
Humidity 100% Relative Humidity
Mechanical Shock 20g half Sine Wave 11 msec. Duration
Electrical Connection PTIH-10-6P Connector or Equivalent
Weight 110 Grams
Pressure Sensing Principle Fully Active Four Arm Wheatstone Bridge Dielectrically Isolated Silicon on Silicon
Mounting Torque 100 Inch-Pounds (Max.)
Pressure Port Connection 7/16-20UNJF-3A MS33656E-4
NOTE: The requirement can be met by manufacturer Kulite, part number BME-76-1100, or an “or equal” commercially available product.