Specification Sheet- Pressure Tansducers.pdf

PDF 564 KB Posted

Attached to
Pressure Transducers
Solicitation number
FA9101_PressureTransducers
Issued by

About this file

This is a specification sheet for a commercially available pressure transducer required under a federal contract opportunity. The Government requires 54 units of pressure transducers capable of measuring hydrogen pressure in the 25-2200 psi range with both absolute and sealed gage operational modes. The transducers must withstand over-pressure conditions at 2x rated pressure and burst pressure up to 5x rated pressure or 15,000 psi maximum.

The transducers must operate across a wide temperature range from -40°F to +265°F (-40°C to +130°C), with compensation between -40°F to +250°F (-40°C to +120°C). Electrical specifications include rated excitation of 8 to 32 VDC with maximum current of 25 mA, full scale output of 4.0 VDC ±0.25 VDC, and a total error band of ±0.25% FSO maximum. The equipment must meet demanding environmental conditions including 100% relative humidity, linear vibration of 20g peak sine wave from 10 to 2000 Hz, and mechanical shock of 20g half sine wave with 11 millisecond duration. Additional requirements include infinitesimal resolution, 110 gram weight, insulation resistance of 100 megohms at 50 VDC, output impedance of 750 megohm maximum, a fully active four-arm Wheatstone bridge dielectrically isolated silicon pressure sensing principle, mounting torque of 100 inch-pounds maximum, electrical connection via PTIH-10-6P connector or equivalent, and pressure port connection of 7/16-20UNJF-3A MS33656E-4. The Government accepts either the Kulite manufacturer part number BME-76-1100 or an "or equal" commercially available product meeting these specifications.

View the file

Other files

File Type Posted
Sources Sought Notice-Pressure Transducers.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specification Sheet

The Government requires commercially available equipment meeting the specifications provided below.

Pressure Transducer Quantity: 54

Specification Value

Media Hydrogen

Pressure Range 25-2200 psi

Operational Mode Absolute, Sealed Gage

Over Pressure 2x Rated Pressure

Burst Pressure 5x Rated Pressure to 15,000 psi Maximum

Rated Electrical Excitation 8 to 32 VDC

Maximum Current 25 mA (Maximum)

Insulation Resistance 100 Megohms @ 50 VDC

Output Impedance 750 Megohm Max

Full Scale Output (Net) 4.0 VDC +/- .25 VDC

Total Error Band (Excluding End Points) +/- .25% FSO Max. (Combined Non-Linearity, Hysteresis, Repeatability, and All Thermal Effects Included)

Resolution Infinitesimal

Operating Temperature Range -40 deg F to +265 deg F (-40 deg C to +130 deg C)

Compensated Temperature Range -40 deg F to +250 deg F (-40 deg C to +120 deg C)

Linear Vibration 20g Peak, Sine 10 to 2000 Hz

Humidity 100% Relative Humidity

Mechanical Shock 20g half Sine Wave 11 msec. Duration

Electrical Connection PTIH-10-6P Connector or Equivalent

DRAFT

Weight 110 Grams

Pressure Sensing Principle Fully Active Four Arm Wheatstone Bridge Dielectrically Isolated Silicon on Silicon

Mounting Torque 100 Inch-Pounds (Max.)

Pressure Port Connection 7/16-20UNJF-3A MS33656E-4

NOTE: The requirement can be met by manufacturer Kulite, part number BME-76-1100, or an “or equal” commercially available product.

DRAFT

Specification Sheet

File details come from the government source that posted it. Updated .