Specification Sheet- Pressure Tansducers.pdf
PDF 564 KB Posted
- Attached to
- Pressure Transducers
- Solicitation number
- FA9101_PressureTransducers
About this file
This is a specification sheet for a commercially available pressure transducer required under a federal contract opportunity. The Government requires 54 units of pressure transducers capable of measuring hydrogen pressure in the 25-2200 psi range with both absolute and sealed gage operational modes. The transducers must withstand over-pressure conditions at 2x rated pressure and burst pressure up to 5x rated pressure or 15,000 psi maximum.
The transducers must operate across a wide temperature range from -40°F to +265°F (-40°C to +130°C), with compensation between -40°F to +250°F (-40°C to +120°C). Electrical specifications include rated excitation of 8 to 32 VDC with maximum current of 25 mA, full scale output of 4.0 VDC ±0.25 VDC, and a total error band of ±0.25% FSO maximum. The equipment must meet demanding environmental conditions including 100% relative humidity, linear vibration of 20g peak sine wave from 10 to 2000 Hz, and mechanical shock of 20g half sine wave with 11 millisecond duration. Additional requirements include infinitesimal resolution, 110 gram weight, insulation resistance of 100 megohms at 50 VDC, output impedance of 750 megohm maximum, a fully active four-arm Wheatstone bridge dielectrically isolated silicon pressure sensing principle, mounting torque of 100 inch-pounds maximum, electrical connection via PTIH-10-6P connector or equivalent, and pressure port connection of 7/16-20UNJF-3A MS33656E-4. The Government accepts either the Kulite manufacturer part number BME-76-1100 or an "or equal" commercially available product meeting these specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sources Sought Notice-Pressure Transducers.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specification Sheet
The Government requires commercially available equipment meeting the specifications provided below.
Pressure Transducer Quantity: 54
Specification Value
Media Hydrogen
Pressure Range 25-2200 psi
Operational Mode Absolute, Sealed Gage
Over Pressure 2x Rated Pressure
Burst Pressure 5x Rated Pressure to 15,000 psi Maximum
Rated Electrical Excitation 8 to 32 VDC
Maximum Current 25 mA (Maximum)
Insulation Resistance 100 Megohms @ 50 VDC
Output Impedance 750 Megohm Max
Full Scale Output (Net) 4.0 VDC +/- .25 VDC
Total Error Band (Excluding End Points) +/- .25% FSO Max. (Combined Non-Linearity, Hysteresis, Repeatability, and All Thermal Effects Included)
Resolution Infinitesimal
Operating Temperature Range -40 deg F to +265 deg F (-40 deg C to +130 deg C)
Compensated Temperature Range -40 deg F to +250 deg F (-40 deg C to +120 deg C)
Linear Vibration 20g Peak, Sine 10 to 2000 Hz
Humidity 100% Relative Humidity
Mechanical Shock 20g half Sine Wave 11 msec. Duration
Electrical Connection PTIH-10-6P Connector or Equivalent
DRAFT
Weight 110 Grams
Pressure Sensing Principle Fully Active Four Arm Wheatstone Bridge Dielectrically Isolated Silicon on Silicon
Mounting Torque 100 Inch-Pounds (Max.)
Pressure Port Connection 7/16-20UNJF-3A MS33656E-4
NOTE: The requirement can be met by manufacturer Kulite, part number BME-76-1100, or an “or equal” commercially available product.