Specification Sheet for Grinder Pumps.docx

DOCX document 287 KB Posted

Attached to
TWO (2) - Myers Pentair Pump Group Grinder Pumps or Equivalent
Solicitation number
70Z02924QNEWO069
Issued by

About this file

This document is a Specification Sheet for two Grinder Pumps required for the United States Coast Guard's IPF New Orleans project. The Coast Guard is seeking two Myers Pentair Pump Group grinder pumps, Model # WGX50-43-25, with specific features including an explosion-proof, submersible centrifugal design, 5 HP motor, and 2 1/2" discharge flange. The period of performance is as soon as possible and no later than May 29, 2024, with delivery to the USCG Industrial Production Detachment in St. Louis, Missouri.

The related federal contract opportunity, Solicitation Number 70Z02924QNEWO069, is a Small Business Set-Aside for the purchase of these two grinder pumps or an equivalent product meeting the same specifications. The contract will be awarded as a firm fixed-price supply order based on the lowest price. Quotes should be submitted via email to the specified Point of Contact by the applicable deadline.

View the file

Other files

File Type Posted
Commercial PO Terms and Conditions - Full Template 20240229.docx DOCX document
SF1449 52065 069 correct.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF HOMELAND SECURITY

UNITED STATES COAST GUARD

IPF NEW ORLEANS

SOW Emergency Sewage Pump for IPD STL Floating Pier

Project location: IPD St. Louis POC: Leonard Raasch Alt POC: Jim Tepen

New Orleans, LA

DESCRIPTION OF WORK:

Provide two (2) each Myers Pentair Pump Group grinder pumps, Model # WGX50-43-25, Explosion Proof, 5 HP Submersible Centrifugal Grinder Pump, 460V, 3 Phase, 60 Hz, 3450 RPM, 70 GPM at a Total Head of 85', with a 2 1/2" Discharge Flange designed for industrial applications.

REQUIRED FEATURES:

· Cable Entry System

· Overload Heat Sensor

· Stainless Steel Shaft

· Stainless Steel Impeller

· Seal Leak Detection

· Oil Filled Motor and Seal Housing

· 50000 Hours Minimum Bearing Life

· Double-Dual Mechanical Shaft Seals with Oil Filled Cavity

· Rated For Hazardous Locations

Period of Performance:

ASAP and no later than 29 May 2024.

References:

N/A

Security Requirements:

NA

DELIVERY LOCATION:

USCG Industrial Production Detachment St. Louis 100 Arsenal St.

Building 17 St. Louis, MO 63118

POINT OF CONTACT (POC):

Leonard Raasch leonard.r.raasch@uscg.mil 314-771-6044 x 2111.

Alternate POC Jim Tepen james.a.tepen@uscg.mil 314-771-6044 x2103

LIABILITIES OF CONTRACTOR:

N/A image1.png