This is a Statement of Work for Project 26Z1AY2, the FSA Horticulture and Composting Program at Alderson, which solicits a composting system for an institutional environment.

The specifications matrix requires contractors to confirm whether their proposed composting machine meets nine key requirements: acceptance of mixed organic waste streams (food waste, shredded paper, lawn clippings, fall leaves); minimization of downtime with capability for continuous waste additions 365 days annually at any time of day without batch processing; handling minimum 1 cubic yard of daily waste inputs; production of usable compost suitable for institutional horticultural needs; reliable operation in both indoor and outdoor locations; incorporation of safety features per Section 2.2; efficient loading mechanisms to minimize staff and inmate worker injuries; and provision of estimated average electrical consumption data. For each requirement, contractors must indicate Yes or No and reference where the specification appears in their cut sheet or submittal.

Section 2.2 establishes mandatory safety and operational features appropriate for a prison environment. The composting system must prevent operator injury during loading, operation, and maintenance; incorporate lockable or restricted-access components to limit unauthorized access; and protect individuals from internal mechanisms and heat concerns. The government seeks comprehensive safety designs and encourages contractors to propose the safest version of their technology, demonstrating high protection levels through their own best practices and innovations.

View the file

Other files for this federal contract opportunity

Other files attached to FPC Alderson - Composter, newest first.
File Type Posted
15B0AT26Q10100001 with SOW.pdf PDF
Statement of Work-Requirement.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work - Project 26Z1AY2 FSA Horticulture and Composting Program Alderson

SPECIFICATIONS MATRIX

Please list if your quoted machine offers the following based on the statement of work:

• Accept mixed organic waste streams including food waste, shredded paper, lawn clippings, and fall leaves.

Yes_____________Where in cut sheet/specifications submittal No

• Minimize downtime, allowing frequent or continuous flow of waste additions with minimal interruptions. Not batch sessions, due to the nature of a prison environment, the composter must be able to accept food scraps 365 days a year as well as any time of day such as 7am, 10am, 11am, and 3pm, etc.

• The ability to handle a minimum of 1 cubic yard of waste inputs daily.

• Produces usable compost appropriate for institutional horticultural needs.

• Operate reliably in both an indoor and outdoor location.

• Safety features described in Section 2.2

• Efficient loading mechanisms to minimize injuries of staff and inmate workers.

• Provides estimated/average electrical consumption as this is a cost savings initiative.

Statement of Work - Project 26Z1AY2 FSA Horticulture and Composting Program Alderson

Yes_____________Where in cut sheet/specifications submittal No

2.2 Safety and Operational Features

The composting system must include safety features appropriate for an institutional environment to protect staff and inmates participating in the vocational program.

Contractors are encouraged to propose the safest version of their technology, describing how their system:

• Prevents operator injury during loading, operation, and maintenance.

• Uses lockable or restricted-access components to limit unauthorized access to the machine.

• Protects individuals from internal mechanisms and heat concerns.

The government seeks solutions with comprehensive safety designs and contractors should demonstrate how their system achieves high protection levels through their own best practices and innovations.

Yes: Ex: Pg X of X
Yes_2:
Yes_3:
Yes_4:
Yes_5:
Yes_6:
Yes_7:
Yes_8:
Check Box18: Off
Check Box19: Off
Check Box20: Off