This specification sheet and federal contract opportunity describe requirements for a rapidly collapsible expeditionary radar shelter. The 266th Range Squadron at Mountain Home Air Force Base seeks a shelter able to contain equipment measuring up to 90 inches wide, 120 inches long, and 160 inches tall. The structure must withstand snow loads up to 15 pounds per square foot and non-operating winds up to 115 miles per hour when collapsed below 5 feet tall. It must include ground anchors and secondary personnel access of at least 72 inches high by 28 inches wide. The contractor will provide manuals and the shelter is to be delivered to the specified vehicle yard within three hours of a two-person team. The contract number is FA489722Q0006 and the solicitation is open for the Department of the Air Force Air Combat Command to procure a shelter meeting the outlined specifications.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation - FA489723Q0006.pdf | ||
| Radar Shelter Drawing Open.png | PNG image | |
| Radar Shelter Drawing Closed.png | PNG image |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIFICATION SHEET
Mountain Home AFB, ID
Radar Clamshell Enclosure 18 April 2023
1.0 GENERAL: The 266th Range Squadron located on Mountain Home AFB, ID requires one
(1) expeditionary radar shelter allowing for rapid teardown and setup to permit operational use while also maximizing equipment protection.
2.0 ENCLOSURE MINIMUM SPECIFICATIONS: The shelter structure must (at a minimum) comply with the following salient characteristics:
2.1. Physical Characteristics
2.1.1. CONTAINMENT: A rapidly collapsible shelter with minimum dimensions able to contain a piece of equipment that is 90” W x 120” L x 160” H.
2.1.2. Required snow load rating 15 psf and non-operating wind speed rating of 115 mph.
2.1.3. When collapsed shall not exceed 5’from the ground.
2.1.4. Must include a bare ground anchor kit capable of performing at above mentioned wind speeds.
2.1.5. Secondary access for personnel to enter shelter without power minimum dimensions of
72” H x 28” W.
2.1.6. Structure must be reusable/relocatable.
2.1.7 The Contractor shall provide two (2) hard copies and one (1) digital copy of an instruction manual for all necessary uses of the shelter to include; setup/installation, teardown, daily operation, open and close, repair process, and related requirements.
2.1.8 Opening and closing mechanism must have electric/motorized and manual options.
2.1.8.1 Motor input power must be 200V - 220V, 3 phase, 60 Hz.
2.1.9 Required structure materials:
2.1.9.1. Fabric: Berry Amendment compliant vinyl, 15oz. desert tan/flat dark earth or forest/hunter green is required for environmental blending.
2.1.9.2. Frame: Powder-coated aluminum.
2.2. Warranty
2.2.1. Frame: 5 years
2.2.2. Fabric: 5 years
2.2.3. Motor: 1 years
3.0. INSTALLATION: Shall take two (2) personnel no longer than three (3) hours to assemble or disassemble.
4.0 SPECIFICS: Contractor shall deliver to 266 RANS Vehicle Yard, 255 Liberator St, Mountain Home AFB ID 83648