This DD Form 2169 is a Special Packaging Instruction (SPI) for a military transmission with container, NSN 2520-01-549-8666, part number 57K6162. The document provides detailed specifications for preserving, cleaning, packing, and shipping a transmission assembly, including precise instructions for:
Key packaging requirements include using MIL-STD-2073-1 preservation methods, applying specific preservatives (MIL-PRF-2104, Grade 15/40 and MIL-PRF-16173, Grade 4), placing 56 units of MIL-D-3464 desiccant in a designated basket, and packing the transmission into a reusable container (P/N 19230). The packed container must be placed in a shaded area and monitored until internal relative humidity stabilizes at or below 30 percent, which typically requires a minimum of 24 hours. The total unit pack weight is 1,560 lbs, with dimensions of 58.0 x 39.5 x 40.5 inches, and the container alone weighs 720 lbs.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation - SPRDL125R0030.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DD FORM 2169, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 1 Pages
SPECIAL PACKAGING INSTRUCTION
Form Approved OMB No. 0704-0188
XCL
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
57K6162 (19207) TRANSMISSION W/ CONTAINER 19207 AK15498666
4. NATIONAL STOCK NUMBER 6. REVISION
2520-01-549-8666
5. DATE OF DRAWING
09-03-2019 -
7. QUP 8. ICQ 9. UNIT PACK WT. (LB) 10. UNIT PACK CU (CU FT) 11. UNIT PACK SIZE (INCHES)
1 EA NONE 1560.0 53.700 58.0 X 39.5 X 40.5
12. MILITARY PRESERVATION (METHOD) 18.
STEPS
19.
REQ’D
20.
DESCRIPTION
MIL-STD-2073-1, METHOD 55 1-B PRESERVATIVE: MIL-PRF-2104, GRADE 15/40
13. CLEANING 2-C PRESERVATIVE: MIL-PRF-16173, GRADE 4
MIL-STD-2073-1, C-1 3-E 56 DESICCANT: MIL-D-3464, TYPE I
14. DRYING 4-F 1 CONTAINER: P/N 19230
MIL-STD-2073-1
15. PACKING
a. LEVEL A
MIL-STD-2073-1 AND NOTE F
b. LEVEL B
NOT APPLICABLE
16. MARKING
MIL-STD-129
17. NOTES / DRAWING
A. INSPECT THE PRESERVATION AND UNIT PACK IAW MIL-STD-2073-1. INSPECT CONTAINER IAW A-
A-52462 INCLUDING THE FIRST ARTICLE INSPECTION.
B. FILL TRANSMISSION ASSEMBLY TO OPERATING LEVEL. ROTATE MECHANISM WHILE FULL TO ENSURE
100% COVERAGE OF PRESERVATIVE ON INTERNAL SURFACES. REMOVE DRAIN PLUG AND DRAIN
EXCESS PRESERVATIVE. REINSTALL DRAIN PLUG AND TORQUE TO 15-20 LBS/FT.
C. COAT ALL UNPAINTED UNPLATED EXTERIOR FERROUS METAL SURFACES.
D. PACK TRANSMISSION INTO 19230 CONTAINER IAW INSTALLATION DECAL LOCATED ON CONTAINER
USING SUPPLIED HARDWARE.
E. PLACE 56 UNITS OF MIL-D-3464 DESICCANT INTO DESIGNATED BASKET.
F. THE UNIT CONTAINER IS THE SHIPPING CONTAINER.
G. PART NUMBER 57K6162 CONSIST OF ONE (1) DRESSED TRANSMISSION, P/N 12512428, AND ONE (1)
REUSABLE CONTAINER, P/N 19230. CONTAINER WEIGHT ALONE IS 720 LBS.
H. THE PACKED REUSABLE CONTAINER WITH ITEM, SHALL BE PLACED IN A SHADED AREA AND
MONITORED UNTIL THE INTERNAL RELATIVE HUMIDITY LEVEL STABILIZES AT OR BELOW 30 PERCENT.
DESICCANT SHALL BE REPLACED AS NEEDED UNTIL THE STABILIZED RELATIVE HUMIDITY IS
ACHIEVED.
(NOTE: THE STABILIZATION OF RELITIVE HUMIDITY TYPICALLY REQUIERS A MINIMUM OF 24 HOURS TO
ACHIEVE.)