Spec 1.pdf
PDF 272 KB Posted
- Attached to
- Electrical Copper Cable Assemblies Federal contract opportunity
- Solicitation number
- N0016724Q0155
About this file
This document is a detailed specification sheet for MIL-DTL-24643/64B, a military specification for twisted shielded pair electrical cables. It provides comprehensive technical requirements for the cable construction, dimensions, electrical properties, physical and environmental performance, and qualification inspection.
The related federal contract opportunity is a solicitation from the Naval Surface Warfare Center Carderock Division (NSWCCD) for Glenair or ODU brand copper electrical cable assemblies. The NSWCCD intends to award a firm fixed-price purchase order using Simplified Acquisition Procedures. The requirement is being solicited on a brand name basis due to the specialized nature of the certified materials. Interested parties may submit capability statements by 10 June 2024 to indicate their interest in this opportunity.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N0016724Q0155 0001.pdf | ||
| Specs Amendment.docx | DOCX document | |
| N0016724Q0155.pdf | ||
| GPE Post.pdf | ||
| REDACTED Brand Name Justification.docx | DOCX document | |
| Spec 2.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMSC N/A FSC 6145
Distribution Statement A. Approved for public release: distribution is unlimited.
INCH-POUND
MIL-DTL-24643/64B
27 November 2023
SUPERSEDING
MIL-DTL-24643/64A
w/INT. AMENDMENT 1
11 July 2011
MIL-DTL-24643/64A
28 January 2010
DETAIL SPECIFICATION SHEET
CABLE, ELECTRICAL, TWISTED SHIELDED PAIR(S), -4 DEGREES FAHRENHEIT (-20 DEGREES
CELSIUS) TO +194 DEGREES FAHRENHEIT (+90 DEGREES CELSIUS), 600 VOLTS, TYPE LSTPSJ
This specification is approved for use by all Departments and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification sheet and
MIL-DTL-24643.
Construction (Non-Watertight)
First - Copper conductor, tin-coated, in accordance with ASTM B286 (see table I for sizes).
Second - Separator may be used at manufacturer’s option where required to provide free stripping insulation.
Third - Thermoset insulation. Nominal 0.010 inch (see table I for finished wire diameter).
Fourth - Two conductors (one black and one white) twisted together with a lay length as specified in table II. Twisted pair identification code applied by method 6 if more than one pair in cable.
Fifth - An optional binder.
Sixth - Braided shield of 36 AWG tin-coated copper. Minimum coverage shall be 90 percent and the braid angle shall be between 20 and 40 degrees.
Seventh - The required number of pairs (see table III) cabled together with a lay length as specified in 3.4.4 of MIL-DTL-24643. Fillers may be used as required to form a firm, well-rounded assembly. Cabling sequence shall be consecutive for four pair cables.
NOTE: For one pair cable, omit the seventh step.
Eighth - An optional binder.
Ninth - Cross-linked polyolefin jacket. Jacket wall thickness shall be 0.030±0.005 inch for cables with core diameters less than 0.300 inch. Jacket wall thickness shall be 0.040±0.005 inch for cables with core diameters greater than or equal to 0.300 inch (see table III for finished cable diameter).
NOTE: Manufacturer’s identification tape is required (see 3.4.9 of MIL-DTL-24643).
Source: http://assist.dla.mil -- Downloaded: 2024-04-03T15:37Z Check the source to verify that this is the current version before use.
TABLE I. Wire configurations and dimensions.
Conductor size
(AWG)
Stranding
(inches)
Conductor diameter
(inch)
(±0.003 inch)
Finished wire diameter (inch) Conductor resistance
(ohms) min. max.
24 19 x 36 0.024 0.041 0.047 25.91
22 19 x 34 0.030 0.047 0.053 16.21
20 19 x 32 0.039 0.056 0.062 9.95
18 19 x 30 0.049 0.066 0.072 6.34
16 19 x 29 0.056 0.073 0.079 4.92
14 19 x 27 0.070 0.087 0.093 3.11
TABLE II. Length of lay.
Wire size range Lay length Twist tolerance
(inch)
20-24 1 ±0.25
14-18 1.5 ±0.25
TABLE III. Finished cable details.
Military part no.
M24643/64
Type and size
Conductor size
(AWG)
Number of pairs
Finished cable diameter (inch)
(±0.016 inch for single pair cables)
(±0.030 inch for multi-pair cables)
-01UN LS1TPSJ-24 24 1 0.170
-02UN LS1TPSJ-22 22 1 0.182
-03UN LS1TPSJ-20 20 1 0.200
-04UN LS1TPSJ-18 18 1 0.220
-05UN LS1TPSJ-16 16 1 0.234
-06UN LS1TPSJ-14 14 1 0.262
-07UN LS2TPSJ-24 24 2 0.260
-08UN LS2TPSJ-22 22 2 0.285
-09UN LS2TPSJ-20 20 2 0.325
-10UN LS2TPSJ-18 18 2 0.390
-11UN LS2TPSJ-16 16 2 0.420
-12UN LS2TPSJ-14 14 2 0.465
-13UN LS3TPSJ-24 24 3 0.275
-14UN LS3TPSJ-22 22 3 0.285
-15UN LS3TPSJ-20 20 3 0.325
-16UN LS3TPSJ-18 18 3 0.390
-17UN LS3TPSJ-16 16 3 0.450
-18UN LS3TPSJ-14 14 3 0.490
-19UN LS4TPSJ-24 24 4 0.295
-20UN LS4TPSJ-22 22 4 0.325
-21UN LS4TPSJ-20 20 4 0.395
-22UN LS4TPSJ-18 18 4 0.450
-23UN LS4TPSJ-16 16 4 0.480
-24UN LS4TPSJ-14 14 4 0.540
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic electricals:
Conductor resistance
(ohms/1,000 feet at 77 °F [25 °C], max.)
See table I
Voltage withstand (volts, root mean square, min.)
Conductor to conductor 2,000
Conductor to shield 1,000
Insulation resistance (megohms/1,000 feet, min.)
Conductor to conductor 500
Conductor to shield 500
Conductor and shield continuity No failure
Jacket flaws No failure
Group A:
Visual and dimensional No failure
Group B:
Cold bending (cable) No failure
Thermoset proof test (percent, max.)
Insulation 50
Jacket (when tested at 392 °F [200 °C]) 50
Physicals (unaged)
Insulation (extruded insulation only)
Tensile strength (lb/in2, min.) 700
Elongation (percent, min.) 150
Jacket (cable)
Tensile strength (lb/in2, min.) 1,300
Elongation (percent, min.) 160
Tear (lb/in thickness, min.) 35
Group C:
Physicals (aged) (air oven)
Insulation (extruded insulation only)
Tensile strength (percent of unaged, min.) 75
Elongation (percent of unaged, min.) 75
Jacket (cable)
Tensile strength (percent of unaged, min.) 60
Elongation (percent of unaged, min.) 60
Shrinkage No failure
Heat distortion (percent of unaged, max.) 30
Permanence of printing (insulation) (cycles, min.)
(applicable to multi-pair cables only)
Permanence of printing (jacket) (cycles, min.) 125
Shield (conformance to material, constructions, and coverage)
No failure
Surface transfer impedance
(type LS1TPSJ only)
Milliohms per meter (max.) Not applicable
Electromagnetic pulse (EMP) response
(dB, min.)
Not applicable
Group D:
Flame propagation (finished cable) No failure
Qualification inspection:
Qualification inspection shall include basic electricals; groups A, B, C, and D; plus the following:
Aging and compatibility (cable) No failure
Abrasion resistance (jacket) (scrapes, min.) 75
Acid gas equivalent (percent, max.)
Jacket 2
Fillers 2
Insulation 18
Halogen content (percent, max.)
Jacket 0.2
Fillers 0.2
Insulation 0.2
Immersion (jacket)
Tensile strength (percent of unaged, min.) 50
Elongation (percent of unaged, min.) 50
Smoke index (max.)
Jacket 25
Fillers 45
Insulation 45
Toxicity index (max.)
Jacket 5
Fillers 5
Insulation 1.5
Weathering (jacket) No failure
Electrical moisture absorption
(extruded insulation only)
No failure
Durometer (jacket) – type A (hardness, min.) 80
UNIT ORDERING LENGTHS:
Type and size Feet (nominal)
LSTPSJ (all sizes) 1,000
CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes.
CONCLUDING MATERIAL
Custodians: Preparing activity:
Army – MI Navy – SH
Navy – SH (Project 6145-2013-080)
Review activities:
Army – AR, CR
Navy – CG, EC
DLA – CC
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the
ASSIST Online database at https://assist.dla.mil.