SPEAG Annual Support and Service Agreement of OET Laboratory Technical Equipment
Statement of Work
May 27, 2021
Location
FCC OET Laboratory 9050 Junction Drive Annapolis Junction, MD 20701
Work to be performed
To provide an annual calibration support and service agreement for the SPEAG list of laboratory test equipment (the DASY system) over the period of August 1, 2021 to July 31, 2022 at a Firm Fixed Price (FFP).
E-Field Probes for Dosimetric Measurements SN
Isotropic E-Field Probe EX3DV3 3509 Isotropic E-Field Probe EX3DV4 3878 Isotropic E-Field Probe EX3DV4 7480
E-Field Probes for General Near Field Applications SN
E-Field Probe EF3DV2 4007
E-Field Probes mm-Wave Probe SN
E-Field Probe for 5G Evaluations EUmmWV4
(delivered February 20)
H-Field Probes SN
Isotropic H-Field Probe H3DV6 6069
Temperature Probes SN
Temperature Probe T1V3 5020
Measurement System SN
Measurement System DASY3 upgrade from DASY3 > DASY4 upgrade from DASY4 > DASY5 upgrade from DASY5 > DASY6 (installed May 2018)
Data Acquisition Electronics DAE3 390 include Mechanical Surface Detection/E-Stop
DASY6 Measurement Server (installed May 2018) 1536 replacing DASY5 Measurement Server 1135 Probe Assignment Unit 232 Optical Transceiver for Surface Detector
Optical Links, cables & grounding material
Robot Remote Control with Safety Circuit V3.0
Dummy Probe DP1
HAC Extensions SN
HAC RF Emission Test Equipment
Test Arch Phantom 1013 DUT Positioner
CD835V3 1083
CD1880V3 1065
CD2450V3 1064
Dipole Positioner
HAC T-coil (ABM) Signal Test Equipment
Active Audio Magnetic Field Probe AM1DV2 1024 Audio Magnetic Measuring Instrument AMMI 1022 Helmholtz Calibration Coil AMCC 1020 Cable Set and adapters
Phantoms SN
SAM Twin phantom V4.0C incl. table TP1015 Mounting Device for Transmitter V3.1
Dipoles SN
D835V2 419 D1900V2 515 D450V2 1008 D2450V2 720 D5GHzV2 1012
CD700V3 1002
D300V3 1018 D750V3 1068 D1750V2 1073 D2600V2 1051
CLA-6 1003
5G System Verification Packages incl. Source SN
System Verification Device (Ka-Band, calibrated at 30 GHz) 1005 (delivered Aug 18, 2019)
System Verification Device (V-Band, calibrated at 60 GHz) 1013
(delivered Aug 18, 2019)
Calibration Services SN
Isotropic E-Field Probe EX3DV3 3509 Isotropic E-Field Probe EX3DV4 3878 Isotropic E-Field Probe EX3DV4 7480 E-Field Probe EF3DV2 4007 Isotropic H-Field Probe H3DV6 6069 Temperature Probe T1V3 5020 Active Audio Magnetic Field Probe AM1DV2 1024 Data Acquisition Electronics DAE3 390 CD700V3 (E & H-field distribution @ 750 MHz) 1002 CD835V3 (E & H-field distribution @ 835 MHz) 1083 CD1880V3 (E & H-field distribution @ 1880 MHz) 1065 CD2450V3 (E & H-field distribution @ 2450 MHz) 1064 D835V2 (includes one calibration) 419 D1900V2 (includes one calibration) 515 D450V2 (includes one calibration) 1008 D2450V2 (includes one calibration) 720 D5GHzV2 (includes two calibrations) 1012 D300V3 (includes one calibration) 1018 D750V3 (includes one calibration) 1068 D1750V2 (includes one calibration) 1073 D2600V2 (includes one calibration) 1051 Confined Loop Antenna CLA-6 (HSL cal @ 6MHz) 1003 Ka-Band System Verification Device (cal @ 30 GHz) 1005 V-Band System Verification Device (cal @ 60 GHz) 1013
Additional Probe Calibrations Quantity
Additional Conversion Factor Assessment 4
EUmmWVx Free Space Probe calibration (incl. CW cal for 0.75- 110GHz) 1
Key Equipment Support Specifications and Deliverables:
Provide technical support, annual calibration, software update and repair services for the RF Exposure measurement system (DASY) used at the FCC Laboratory in Columbia, MD.
Deliverable
The test equipment vendor shall provide technical support for the operation of the RF Exposure Measurement System. This support will include calibration services of the equipment listed above, software updates and repair services, & one-time return shipment of calibrated items (DPP to Columbia, MD including handling, freight, custom duties, and insurance). The return shipment of the items shall be included in the agreement. The vendor will perform the calibration services at their overseas facility.