ATTACH_PID_Packaging_and_Marking.pdf
PDF 75 KB Posted
- Solicitation number
- SPE7MX19R0045
About this file
PID, Packaging and Marking
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SPE7MX19R0045_-_reviewed_Redacted.pdf | ||
| Encl_B-1_to_SPE7MX19D0052P0001.docx | DOCX document | |
| SF30_SPE7MX19D0052P00001.pdf | ||
| ATTACH_Solicitation.pdf | ||
| SF26_SPE7MX19D0052.pdf | ||
| Signed_1st_Page_(0052).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
*** LTC PID Packaging Consolidated Text *** PLEASE SEE GLOSSARY AT THE END OF THE DOCUMENT FOR FULL TEXT OF THE ITEM DESCRIPTION
AND PACKAGING REFERENCE NUMBERS CALLED OUT FOR EACH NSN.
NSN:013926648
ACTUATOR, ELECTRO-MECHANICAL, ROTARY.
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:CS241
REFERENCE NUMBER:CS199
CRITICAL APPLICATION ITEM
MORPAC INDUSTRIES, INC. DBA 66822 P/N 20009 ASSY 1
MORPAC INDUSTRIES, INC. DBA 66822 P/N 20009-1
PREP FOR DELIVERY
LINE ITEM 00001 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:52 CLNG/DRY:1 PRESV MAT:ZZ
WRAP MAT:GC CUSH/DUNN MAT:AD CUSH/DUNN THKNESS:F
UNIT CONT:GB OPI:M
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
PRESERVATIVE MATERIAL: ZZ - USE 89 PRESERVATION MATERIAL AS FOLLOWS -
ALL BARE METAL SHALL BE PROPERLY PRESERVED TO PREVENT CORROSION. ALL
MOVING PARTS SHALL BE PROPERLY LUBRICATED. EACH ITEM SHALL BE
INDIVIDUALLY PACKAGED.
PACKAGE DESIGN MUST IMMOBILIZE ITEM WITHIN CONTAINER TO ADEQUATELY
PACKAGE AND PROTECT ITEM. UNIT CONTAINER SELECTION MUST ADEQUATELY
CONTAIN AND PROTECT MATERIAL. WOODEN BOX SHALL HAVE AN INSPECTION
WINDOW.
ZZ = ADDITIONAL SPECIAL MARKING REQUIREMENTS:
THIS NSN IS IDENTIFIED AS A REPAIRABLE ITEM. MIL-STD-2073-1<(>,<)>
APPENDIX C COVERS REUSABLE CONTAINERS FOR REPAIRABLE ITEMS.
THESE CONTAINERS SHALL BE PROPERLY IDENTIFIED TO ENSURE
REUSE FOR THE PRODUCT AS FOLLOWS:
02 - ARROW UP
03 - METHOD 50;
13 - OPEN THIS SIDE;
14 - CENTER OF BALANCE
19 - METHOD 50 REUSABLE CONTAINER
24 - OPEN FOR INSPECTION OR USE ONLY
WHEN SPECIFIED/REQUIRED: PER MIL-STD-129<(>,<)>
SERIAL NUMBER SHALL BE MARKED ON THE UNIT<(>,<)>
INTERMEDIATE, AND SHIPPING CONTAINERS.
NSN:013990948
ACTUATOR,ELECTRO-MECHANICAL, ROTARY
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:CA061
CRITICAL APPLICATION ITEM
MORPAC INDUSTRIES, INC. DBA 66822 P/N 20008 ASSY 3
MORPAC INDUSTRIES, INC. DBA 66822 P/N 20008-3
LINE ITEM 00002 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:52 CLNG/DRY:1 PRESV MAT:ZZ
WRAP MAT:GC CUSH/DUNN MAT:AD CUSH/DUNN THKNESS:F
UNIT CONT:GB OPI:M
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
PRESERVATIVE MATERIAL: ZZ - USE 89 PRESERVATION MATERIAL AS FOLLOWS -
ALL BARE METAL SHALL BE PROPERLY PRESERVED TO PREVENT CORROSION. ALL
MOVING PARTS SHALL BE PROPERLY LUBRICATED. EACH ITEM SHALL BE
INDIVIDUALLY PACKAGED.
PACKAGE DESIGN MUST IMMOBILIZE ITEM WITHIN CONTAINER TO ADEQUATELY
PACKAGE AND PROTECT ITEM. UNIT CONTAINER SELECTION MUST ADEQUATELY
CONTAIN AND PROTECT MATERIAL. WOODEN BOX SHALL HAVE AN INSPECTION
WINDOW.
THIS NSN IS IDENTIFIED AS A REPAIRABLE ITEM. MIL-STD-2073-1<(>,<)>
APPENDIX C COVERS REUSABLE CONTAINERS FOR REPAIRABLE ITEMS.
THESE CONTAINERS SHALL BE PROPERLY IDENTIFIED TO ENSURE
REUSE FOR THE PRODUCT AS FOLLOWS:
ZZ - ADDITIONAL SPECIAL MARKING REQUIREMENTS:
02 - ARROW UP
03 - METHOD 50;
13 - OPEN THIS SIDE;
14 - CENTER OF BALANCE
19 - METHOD 50 REUSABLE CONTAINER
24 - OPEN FOR INSPECTION OR USE ONLY
WHEN SPECIFIED/REQUIRED: PER MIL-STD-129<(>,<)>
SERIAL NUMBER SHALL BE MARKED ON THE UNIT<(>,<)>
INTERMEDIATE, AND SHIPPING CONTAINERS.
NSN:014220876
VALVE,BUTTERFLY
REFERENCE NUMBER:RP001
REFERENCE NUMBER:A1202
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:CS241
REFERENCE NUMBER:CS199
REFERENCE NUMBER:ZD025
CRITICAL APPLICATION ITEM
MORPAC INDUSTRIES, INC. DBA 66822 P/N 10005-3
LINE ITEM 00003 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:53 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:CA CUSH/DUNN MAT:AD CUSH/DUNN THKNESS:F
UNIT CONT:F7 OPI:M
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
PACKAGE DESIGN MUST IMMOBILIZE ITEM WITHIN CONTAINER TO ADEQUATELY
PACKAGE AND PROTECT ITEM. UNIT CONTAINER SELECTION MUST ADEQUATELY
CONTAIN AND PROTECT MATERIAL. WOODEN BOX SHALL HAVE AN INSPECTION
WINDOW.
THIS NSN IS IDENTIFIED AS A REPAIRABLE ITEM. MIL-STD-2073-1<(>,<)>
APPENDIX C COVERS REUSABLE CONTAINERS FOR REPAIRABLE ITEMS.
THESE CONTAINERS SHALL BE PROPERLY IDENTIFIED TO ENSURE
REUSE FOR THE PRODUCT AS FOLLOWS:
ZZ - ADDITIONAL SPECIAL MARKING REQUIREMENTS:
02 - ARROW UP
03 - METHOD 50;
13 - OPEN THIS SIDE;
14 - CENTER OF BALANCE
19 - METHOD 50 REUSABLE CONTAINER
24 - OPEN FOR INSPECTION OR USE ONLY
WHEN SPECIFIED/REQUIRED: PER MIL-STD-129<(>,<)>
NSN:014483989
VALVE, GATE
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ002
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:CS241
REFERENCE NUMBER:CS199
MORPAC INDUSTRIES, INC. DBA 66822 P/N 10018-1
MORPAC INDUSTRIES, INC. DBA 66822 P/N 10018-2
LINE ITEM 00004 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:53 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:CA CUSH/DUNN MAT:AD CUSH/DUNN THKNESS:F
UNIT CONT:F7 OPI:M
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
PACKAGE DESIGN MUST IMMOBILIZE ITEM WITHIN CONTAINER TO ADEQUATELY
PACKAGE AND PROTECT ITEM. UNIT CONTAINER SELECTION MUST ADEQUATELY
CONTAIN AND PROTECT MATERIAL. WOODEN BOX SHALL HAVE AN INSPECTION
WINDOW.
THIS NSN IS IDENTIFIED AS A REPAIRABLE ITEM. MIL-STD-2073-1<(>,<)>
APPENDIX C COVERS REUSABLE CONTAINERS FOR REPAIRABLE ITEMS.
THESE CONTAINERS SHALL BE PROPERLY IDENTIFIED TO ENSURE
REUSE FOR THE PRODUCT AS FOLLOWS:
ZZ - ADDITIONAL SPECIAL MARKING REQUIREMENTS:
02 - ARROW UP
03 - METHOD 50;
13 - OPEN THIS SIDE;
14 - CENTER OF BALANCE
19 - METHOD 50 REUSABLE CONTAINER
24 - OPEN FOR INSPECTION OR USE ONLY
WHEN SPECIFIED/REQUIRED: PER MIL-STD-129<(>,<)>
GLOSSARY
PACKAGING TEXT
THE FOLLOWING PARAGRAPH APPLIES TO ALL PACKAGING CALLED OUT IN THIS DOCUMENT:
ITEM DESCRIPTION TEXT
REFERENCE NUMBER RP001
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
REFERENCE NUMBER RA001
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT: http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx. FOR
SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE
SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE
ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE
APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON
REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
REFERENCE NUMBER RQ011
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
REFERENCE NUMBER CS241
NOTE: THIS IS A RESTRICTED SOURCE ITEM AND
REQUIRES ENGINEERING SOURCE APPROVAL BY THE
GOVERNMENT DESIGN CONTROL ACTIVITY.
REFERENCE NUMBER CS199
ALTERNATE OFFEROR REQUIREMENTS:
THE FOLLOWING DOCUMENTATION IS REQUIRED IN
ACCORDANCE WITH MIL-T-31000. (A) ALL DRAWINGS
AND SPECIFICATIONS REQUIRED FOR MANUFACTURE.
(B) PROCESS/OPERATION SHEETS WHICH DESCRIBE
IN DETAIL EACH CRITICAL PROCESS AND ASSOCIATED
INSPECTION/ACCEPTANCE CRITERIA. (C)
IDENTIFICATION OF SOURCES WHO WILL PERFORM
CRITICAL PROCESSES/OPERATIONS, INCLUDING
SOURCES OF FORGINGS AND CASTINGS. (D) IF
AVAILABLE COPIES OF PURCHASE ORDERS FROM THE
ITEM. (E) A SHOCK EXTENSION REPORT IN
ACCORDANCE WITH MIL-S-901 AND IN A FORMAT AS
SPECIFIED IN DI-ENVR-80706 IS REQUIRED.
IF THE OEM'S DETAILED DRAWINGS ARE NOT
AVAILABLE, THE OFFEROR MUST SUPPLY AN
ENGINEERING ANALYSIS REPORT WHICH DETAILS HOW
THEIR DRAWINGS WERE DEVELOPED. ADDITIONALLY,
IF REVERSE ENGINEERING WAS USED, THE COMPLETE
PROCEDURE WILL BE REPORTED INCLUDING: NUMBER
OF SAMPLES, METHODS AND MEASURES USED, ALL DATA
COMPILED, RATIONALE FOR DIMENSION TOLERANCE
DEVIATION, AND RATIONALE FOR ACCEPTANCE. THIS
DATA WILL BE FORWARDED TO THE ENGINEERING
SUPPORT ACTIVITY FOR EVALUATION.
REFERENCE NUMBER CA061
ADEQUATE DATA FOR THE EVALUATION OF ALTERNATE
OFFERS IS NOT AVAILABLE AT THE PROCUREMENT
AGENCY.THE OFFEROR MUST PROVIDE A COMPLETE
DATA PACKAGE INCLUDING DATA FOR THE APPROVED
AND ALTERNATE PART FOR EVALUATION.
REFERENCE NUMBER A1202
Casting/forging may be required to manufacture this NSN. If a casting/forging is required, tooling is typically involved. The government may not have this special tooling. For sourcing, tooling, materials or other information, please contact the appropriate assistance team: (Aviation, C&E Supply Chains) DSCR.AFCAT@dla.mil; (Land & Maritime Supply Chains) DSCC.cast.forge@dla.mil
REFERENCE NUMBER ZD025
MERCURY OR MERCURY CONTAINING COMPOUNDS SHALL
NOT BE INTENTIONALLY ADDED TO<(>,<)> OR COME IN DIRECT
CONTACT WITH<(>,<)> ANY HARDWARE OR SUPPLIES FURNISHED
UNDER THIS CONTRACT. EXCEPTION: FUNCTIONAL MERCURY
USED IN BATTERIES, FLUORESCENT LIGHTS, REQUIRED
INSTRUMENTS; SENSORS OR CONTROLS; WEAPON SYSTEMS;
AND CHEMICAL ANALYSIS REAGENTS SPECIFIED BY NAVSEA.
PORTABLE FLUORESCENT LAMPS AND PORTABLE INSTRUMENTS
CONTAINING MERCURY SHALL BE SHOCK PROOF AND CONTAIN
A SECOND BOUNDARY OF CONTAINMENT OF THE MERCURY OR
MERCURY COMPOUND. (IAW NAVSEA 5100-003D).
REFERENCE NUMBER RQ002
RQ002: CONFIGURATION CHANGE MANAGEMENT - ENGINEERING CHANGE PROPOSAL
REQUEST FOR VARIANCE (DEVIATION OR WAIVER)
File details come from the government source that posted it.