05/13/16 PID PACK Text *** LTC PID Packaging Consolidated Text *** PLEASE SEE GLOSSARY AT THE END OF THE DOCUMENT FOR FULL TEXT OF THE ITEM DESCRIPTION
AND PACKAGING REFERENCE NUMBERS CALLED OUT FOR EACH NSN.
NSN:013763342
BARREL,GRENADE LAUN
THIS ITEM IS A "DEFENSE ARTICLE" AS DEFINED IN
AND SUBJECT TO THE INTERNATIONAL TRAFFIC IN ARMS
REGULATIONS (22 C.F.R. 120-30) AND THE ARMS
EXPORT CONTROL ACT (22 U.S.C.A. 2778-2799).
ANY MANUFACTURER OR EXPORTER OF DEFENSE ARTICLES
IS REQUIRED TO REGISTER WITH THE DIRECTORATE OF
DEFENSE TRADE CONTROLS (DDTC), DEPARTMENT OF
STATE. DOCUMENTARY EVIDENCE OF REGISTRATION MAY
BE REQUIRED PRIOR TO AWARD. ADDITIONAL EXPORT
RESTRICTIONS APPLY AS INDICATED HEREIN. FAILURE
TO SUBMIT DDTC REGISTRATION WHEN REQUESTED WILL
MAKE A QUOTE/OFFER INELIGIBLE FOR AWARD.
REFERENCE NUMBER:ES371
REFERENCE NUMBER:ZLM10
GFP-STANDARD ROUND OF TEST AMMUNITION<(>,<)>
1310-01-211-8073] IS REQUIRED ON THIS ITEM FOR EACH
BARREL TO BE DELIVERED. ONE ROUND OF GFP IS REQUIRED
FOR EACH BARRELL, EXAMPLE, A CONTRACT FOR 226 WOULD
REQUIRE GFP QUANTITY OF 226.
_______________EXCEPTION DATA____________________
IF DRAWING NOTE GIVES OPTION FOR ZINC OR
MANGANESE COATING THEN MANGANESE IS REQUIRED.
*************** NO EXCEPTIONS ********************
______________END OF EXCEPTIONS__________________
__________SPECIAL PACKAGING INSTRUCTIONS_________
********* SEE SPECIAL PACAKGING DOCUMENT **********
______END OF SPECIAL PACKAGING INSTRUCTIONS______
THE ITEM BEING PROCURED IS A CRITICAL GUN PART
ITEM WITH UNIQUE REQUIREMENTS.
CONTRACTOR FAT APPLIES.
AFTER RECEIPT OF QUOTES, OFFERORS MAY BE
CONTACTED TO PRICE THE FAT REQUIREMENT.
PROCESS PROCEDURES AND OR WORKMANSHIP SPECIMENS
REQUIRED BY MILITARY SPECIFICATION (S) APPLICABLE
TO THIS CONTRACT WILL BE APPROVED BY THE CONTRACT
POST AWARD CONTRACTING OFFICER (PCO).
PRODUCT INSPECTION WILL BE CONDUCTED BY THE DCMA
QAR AT THE ACTUAL MANUFACTURER'S FACILITY.
THE IDENTIFICATION OF THE ACTUAL
MANUFACTURER AND PHOSPHATE CONTRACTOR MUST BE
SUBMITTED TO THE CONTRACTING OFFICER FOR
INCLUSION IN THE AWARD. UPON AWARD, ANY CHANGES
TO THE ABOVE MUST BE APPROVED BY THE PCO VIA
FORMAL CONTRACT MODIFICATION.
THIS NSN CONTAINS ONE OR MORE COMPONENTS WHICH
MUST MEET QPL/QML SPECIFICATIONS AS IDENTIFIED
IN THE TECHNICAL DATA PACKAGE. CLAUSE I09A01
(FAR CLAUSE 52.209-1) QUALIFICATION REQUIREMENTS
IS APPLICABLE. THE AWARDEE SHALL PROVIDE QPL/QML
COMPONENTS ONLY FROM SOURCES QUALIFIED ON THE
APPLICABLE QPL(S)/QML(S). THE IDENTIFICATION OF
ALL APPLICABLE QPL/QML SOURCES MUST BE SUBMITTED
TO THE CONTRACTING OFFICER FOR EVALUATION PRIOR
TO CONTRACT AWARD.
PRODUCT VERIFICATION TESTING (PVT) CLAUSE DLAD
52.246-9004 MAY BE INVOKED FOR THE REFERENCED
CONTRACT. IF INVOKED, PVT SAMPLES MUST BE
INSPECTED, PACKAGED AND MARKED AS REQUIRED IN
THE CONTRACT. ONE (1) SAMPLE MAY BE DESTROYED
DURING TESTING.
PRODUCT VERIFICATION TESTING, IF INVOKED<(>,<)>
WILL BE PERFORMED PRIOR TO ACCEPTANCE OF
EACH SHIPMENT. THE CONTRACTOR MUST PROVIDE
PVT SAMPLES FROM EACH (SUB)CONTRACTOR USED
IN THE PRODUCTION OF PARTS ON THIS CONTRACT.
FIVE (5) PVT SAMPLES, UNLESS OTHERWISE
SPECIFIED, WILL BE REQUIRED TO BE IDENTIFIED
TO THOSE (SUB)CONTRACTORS WHEN THEY ARE SENT
IN FOR TESTING.
CERTIFICATE OF CONFORMANCE IS NOT AUTHORIZED.
REFERENCE NUMBER:ZL006
REFERENCE NUMBER:CS187
REFERENCE NUMBER:ZD059
REFERENCE NUMBER:CQC04
REFERENCE NUMBER:ZD025
REFERENCE NUMBER:CS001
CRITICAL APPLICATION ITEM
IAW BASIC DRAWING NR 19200 12012005
REVISION NR D DTD 10/17/2002
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 11838036
REVISION NR C DTD 05/29/2008
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 12002894
REVISION NR G DTD 10/30/2008
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 12011988
REVISION NR F DTD 09/03/2010
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 12012006
REVISION NR N DTD 03/02/2010
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 12012007
REVISION NR E DTD 03/02/2010
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 12012008
REVISION NR F DTD 04/20/2009
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 12579607
REVISION NR C DTD 08/04/2009
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 8448312
REVISION NR N DTD 10/27/2011
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 8448301
REVISION NR H DTD 10/30/2008
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 8448306
REVISION NR G DTD 12/18/2007
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 8448315
REVISION NR P DTD 05/19/2011
PART PIECE NUMBER:
IAW REFERENCE SPEC NR MIL-DTL-16232G NOT 1
REVISION NR G DTD 10/03/2006
PART PIECE NUMBER:
IAW REFERENCE UNK QPL-3150-34 NOT 1
REVISION NR 34 DTD 10/03/2006
PART PIECE NUMBER:
IAW REFERENCE UNK QPL-16173-84 NOT 1
REVISION NR 84 DTD 10/03/2006
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 13011863
REVISION NR C DTD 12/27/2010
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 12993884
REVISION NR G DTD 07/18/2013
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19204 L2S3025
REVISION NR D DTD 05/03/2002
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 13027484
REVISION NR DTD 09/22/2009
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 L11S2002
REVISION NR D5 DTD 03/11/2011
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 1145
REVISION NR F DTD 05/18/1992
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 12012005
REVISION NR DTD 05/07/2012
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 12012005
REVISION NR DTD 05/07/2012
PART PIECE NUMBER:
IAW REFERENCE DRAWING NR 19200 L12S3044
REVISION NR DTD 05/09/2012
PART PIECE NUMBER:
PREP FOR DELIVERY
LINE ITEM 00001 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:ZZ CLNG/DRY:Z PRESV MAT:ZZ
WRAP MAT:ZZ CUSH/DUNN MAT:ZZ CUSH/DUNN THKNESS:Z
UNIT CONT:ZZ OPI:A
INTRMDTE CONT:ZZ INTRMDTE CONT QTY:ZZZ
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PACKAGING SHALL BE IN ACCORDANCE WITH SPECIAL
PACKAGING INSTRUCTION AM12012005, REVISION E, DATED
18JUN2010.
ITEM IS EXPORT CONTROLLED. MIL-STD-2073 SPECIAL
MARKINGS CODE 40 APPLIES.
GLOSSARY
PACKAGING TEXT
THE FOLLOWING PARAGRAPH APPLIES TO ALL PACKAGING CALLED OUT IN THIS DOCUMENT:
ITEM DESCRIPTION TEXT
REFERENCE NUMBER ES371
DLAD PROVISION 52.211-9009 IS APPLICABLE TO THIS
SOLICITATION, THEREFORE SURPLUS MATERIAL WILL
NOT BE CONSIDERED. IF PRESENT IN THE
SOLICITATION, PROVISION 52.211-9003 AND CLAUSE
52.211-9000 ARE NOT APPLICABLE.
REFERENCE NUMBER ZLM10
THIS ITEM HAS BEEN DETERMINED TO BE A SECURITY RISK.
DFARS 252.223-7007 Safeguarding Sensitive Conventional Arms, Ammunition, and Explosives applies.
REFERENCE NUMBER ZL006
This item contains a phosphate coating requirement IAW MIL-STD-171 and MIL-DTL-16232. In lieu of the required submittal of a preproduction phosphate procedure the following is now required: The contractor responsible for the actual coating procedure must be certified by the Performance Review Institute (PRI) to the Nadcap standard for chemical processes. Verification of this certification may be required and must be supplied upon request of the Contracting Officer.
REFERENCE NUMBER CS187
CLASS I OZONE DEPLETING CHEMICALS ARE NOT TO BE
USED NOR INCORPORATED IN ANY ITEMS TO BE
DELIVERED UNDER THIS CONTRACT.THIS PROHIBITION
SUPERSEDES ALL SPECIFICATION REQUIREMENTS BUT
DOES NOT ALLEVIATE ANY PRODUCT REQUIREMENTS.
SUBSTITUTE CHEMICALS MUST BE SUBMITTED FOR
APPROVAL UNLESS THEY ARE AUTHORIZED BY THE
SPECIFICATION REQUIREMENTS.
REFERENCE NUMBER ZD059
52.246-11 Higher Level Contract Quality Requirement (Manufacturers)
FAR CLAUSE 52.246-11 APPLIES. A QUALITY MANAGEMENT PROGRAM MEETING THE
REQUIREMENTS OF ISO 9001:2008; A PROGRAM COMPARABLE TO ISO 9001:2008
(EXAMPLE SAE AS 9100), THE FOLLOWING TAILORED VERSION OF ISO 9001:2008;
OR A PROGRAM COMPARABLE TO THE TAILORED VERSION OF ISO 9001:2008
(EXAMPLE SAE AS 9003) IS REQUIRED. MIL-I-45208 AND MIL-Q-9858 ARE
OBSOLETE AND NO LONGER CONSIDERED SUITABLE WHEN HIGHER LEVEL QUALITY IS
REQUIRED. IN THE TAILORED VERSION OF THE ISO 9001:2008, ANY REFERENCES
WHICH CITE THE ENTIRE INTERNATIONAL STANDARD ARE INTERPRETED AS
EXCLUSIONS TO THIS DOCUMENT.
DLA TAILORED HIGHER LEVEL QUALITY CLAUSE FROM ISO 9001:2008
4.1 General requirements, [excluding reference to 1.2 and excluding NOTE 3 c)]
4.2.1 General, [excluding subparagraph a)]
4.2.2 Quality manual, [excluding subparagraph a)]
4.2.3 Control of documents
4.2.4 Control of records
5.1 Management commitment
5.3 Quality policy
6.2.2 Competence, training and awareness
6.4 Work environment
7.1 Planning of product realization, [excluding NOTE 2]
7.2.1 Determination of requirements related to the product
7.2.2 Review of requirements related to the product
7.2.3 Customer communication
7.3.7 Control of design and development changes
7.4.1 Purchasing process
7.4.3 Verification of purchased product
7.5.1 Control of production and service provision
7.5.3 Identification and traceability
7.5.4 Customer property
7.5.5 Preservation of product
7.6 Control of monitoring and measuring equipment
8.1 General, [excluding subparagraph b) and subparagraph c)]
8.2.2 Internal audit
8.2.4 Monitoring and measurement of product
8.3 Control of nonconforming product
8.5.2 Corrective action
8.5.3 Preventive action
REFERENCE NUMBER CQC04
DLAD 52.246-9003, MEASURING AND TEST EQUIPMENT,
APPLIES.
REFERENCE NUMBER ZD025
MERCURY OR MERCURY CONTAINING COMPOUNDS SHALL
NOT BE INTENTIONALLY ADDED TO<(>,<)> OR COME IN DIRECT
CONTACT WITH<(>,<)> ANY HARDWARE OR SUPPLIES FURNISHED
UNDER THIS CONTRACT. EXCEPTION: FUNCTIONAL MERCURY
USED IN BATTERIES, FLUORESCENT LIGHTS, REQUIRED
INSTRUMENTS; SENSORS OR CONTROLS; WEAPON SYSTEMS;
AND CHEMICAL ANALYSIS REAGENTS SPECIFIED BY NAVSEA.
PORTABLE FLUORESCENT LAMPS AND PORTABLE INSTRUMENTS
CONTAINING MERCURY SHALL BE SHOCK PROOF AND CONTAIN
A SECOND BOUNDARY OF CONTAINMENT OF THE MERCURY OR
MERCURY COMPOUND. (IAW NAVSEA 5100-003D).
REFERENCE NUMBER CS001
THIS ITEM HAS TECHNICAL DATA SOME OR ALL OF WHICH IS SUBJECT TO
EXPORT-CONTROL REGULATIONS. DISTRIBUTION OF THE TECHNICAL DATA
AND ELIGIBILITY FOR AWARD ARE LIMITED TO THOSE SUPPLIERS QUALIFIED
THROUGH JCP CERTIFICATION, OR TO THOSE LICENSED BY EITHER THE
DEPARTMENTS OF STATE OR COMMERCE; OR TO FOREIGN SUPPLIERS PURSUANT TO
INTERNATIONAL AGREEMENTS.
TO APPLY FOR JCP CERTIFICATION, COMPLETE DD FORM 2345, MILITARY
CRITICAL TECHNICAL DATA AGREEMENT, FORM IS AVAILABLE AT THE WORLD WIDE
WEB ADDRESS:
https://public.logisticsinformationservice.dla.mil/PublicHome/jcp/defaul t.aspx
OR BY WRITING TO:
DLA LOGISTICS INFORMATION SERVICE
FEDERAL CENTER
74 WASHINGTON AVE., NORTH
BATTLE CREEK, MI 49037-3084
TO MANUFACTURE THIS ITEM, NON-JCP CERTIFIED SUPPLIERS MUST SUBMIT A
CURRENT MANUFACTURING LICENSE AGREEMENT, TECHNICAL ASSISTANCE AGREEMENT,
DISTRIBUTION AGREEMENT OR OFF-SHORE PROCUREMENT AGREEMENT APPROVED BY
THE DIRECTORATE OF DEFENSE TRADE CONTROLS WITH THE OFFER, UNLESS AN
EXEMPTION UNDER THE PROVISIONS OF ITAR SECTION, 125.4 EXEMPTIONS OF
GENERAL APPLICABILITY, AND/OR EAR PART 740 ARE APPLICABLE.
NON-JCP CERTIFIED SUPPLIERS SEEKING EXPORT CONTROLLED TECHNICAL
DATA ARE REQUIRED TO PROVIDE THE CONTRACTING OFFICER WITH AN
APPLICABLE AGREEMENT OR IDENTIFY WHICH ITAR/EAR EXEMPTION APPLIES TO
RECEIVE A COPY OF THE EXPORT CONTROLLED TECHNICAL DATA.
NOTE: JCP CERTIFIED CONTRACTORS WHO RECEIVE TECHNICAL DATA PURSUANT TO
THEIR DD FORM 2345 CERTIFICATION MAY NOT FURTHER DISSEMINATE SUCH DATA
UNLESS FURTHER DISSEMINATION OF THE TECHNICAL DATA IS EXPRESSLY
PERMITTED BY DODD 5230.25.
File details come from the government source that posted it. Updated .