Attachment_3_-_DLA_BTW_QA_Requirements.doc
DOC document 147 KB Posted
- Attached to
- Bottled Water - Israel
- Solicitation number
- SPE303-18-Q-0003
About this file
Attachment 3 - DLA BTW QA Requirements
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF30_SPE30318Q00030001.pdf | ||
| Attachment_1_-_SOW_BTW_Israel.docx | DOCX document | |
| SPE303-18-Q-0003.pdf | ||
| Attachment_2_-_Delivery_Locations.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bottled Water Monitoring Parameters
Attachment 3 – DLA BTW QA Requirements
SPE303-18-A-XXXX
1. In coordination with Public Health Command Europe Laboratory Services and the Public Health Command Europe Veterinary Services Division (PHCE VSD), DLA TROOP SUPPORT EUROPE & AFRICA Food Safety and Quality Assurance recommends these parameters for the quality assurance section of DLA TROOP SUPPORT EUROPE & AFRICA bottled water acquisitions for the AFRICOM, EUCOM and CENTCOM areas of responsibility.
2. REFERENCES:
a. Code of Federal Regulations, Title 21, Volume 2, Parts 129 and 165
b. Code of Federal Regulations, Title 40, Volume 25, Parts 141 and 143
c. Bottled Water Laboratory – Auditor Checklist, Appendix B
d. EU Directive 98/ 93/ EC, 14 December 1998
e. MIL-STD 3006C, 01 June 2008
f. International Bottled Water Associate, Bottled Water Code of Practice
g. Worldwide Directory Of Sanitarily Approved Food Establishments For Armed Forces Procurement, Appendix O - DoD Food Safety and Quality Assurance Action Levels, 19 Aug 2016.
3. The following parameters must be monitored:
| MONITORING PARAMETER GROUP |
| MONITORING |
FREQUENCY
FDA Standard of Quality (SOQ) Limits in mg/L (ppm) except as noted.
Individual Group Analytes
| Inorganic Chemicals (IOCs) |
| ANNUALLY |
| Antimony (1) |
| ANNUALLY |
(Product and Source)
0.006
Arsenic
0.01
Barium
2.0
Beryllium (1)
0.004
Bromate (2)
0.010
Cadmium
0.005
Chlorine (2)
4.0
Chloramine (2)
4.0
Chlorine dioxide (2)
0.8
Chlorite (2)
1.0
Chromium, Total
0.1
Cyanide (1)
0.1
Lead
0.005
Mercury
0.002
Nickel (1)
0.1
Nitrate-N
10.0
Nitrite-N
1.0
Total Nitrate + Nitrite
10.0
Selenium
0.05
Thallium (1)
0.002
| Secondary Inorganic Parameters |
| ANNUALLY |
| Aluminum |
| ANNUALLY |
0.2
Chloride (5)
Copper
1.0
Iron (5)
0.3
Manganese (5)
0.05
Silver
0.1
Sulfate (5)
Total Dissolved Solids (TDS) (5)
Zinc (5)
5.0
| Volatile Organic Chemicals (VOCs) |
| ANNUALLY |
| 1,1,1-Trichloroethane |
| ANNUALLY |
0.2
1,1,2-Trichloroethane
0.005
1,1-Dichloroethylene
0.007
1,2,4-Trichlorobenzene
0.07
1,2-Dichloroethane
0.005
1,2-Dichloropropane
0.005
Benzene
0.005
Carbon tetrachloride
0.005 cis-1,2-Dichloroethylene
0.07 trans-1,2-Dichloroethylene
0.1
Ethylbenzene
0.7
Methylene chloride (Dichloromethane)
0.005
Monochlorobenzene
0.1 o-Dichlorobenzene
0.6 p-Dichlorobenzene
0.075
Haloacetic Acids (HAA5) (2)
0.06
Styrene
0.1
| MONITORING PARAMETER GROUP |
| MONITORING |
FREQUENCY
FDA Standard of Quality (SOQ) Limits in mg/L (ppm) except as noted.
Individual Group Analytes
| Volatile Organic Chemicals (VOCs) (Continued) |
| ANNUALLY |
| Tetrachloroethylene |
| ANNUALLY |
0.005
Toluene
1.0
Trichloroethylene
0.005
Vinyl chloride
0.002
Xylenes (total)
10.0
Total Trihalomethanes (2)(7)
0.08
| Semivolatile Organic Chemicals (SVOCs) |
| ANNUALLY |
| Benzo(a)pyrene |
| ANNUALLY |
0.0002
Di(2-ethyhexyl)adipate
0.4
Di(2-ethyhexyl)phthalate
0.006
Hexachlorobenzene
0.001
Hexachlorocyclopentadiene
0.05
| Synthetic Organic Chemicals (SOCs) |
| ANNUALLY |
| 2,4,5-TP (Silvex) |
| ANNUALLY |
0.05
2,4-D (Dichlorophenoxy acetic acid)
0.07
Alachlor
0.002
Atrazine
0.003
Carbofuran
0.04
Chlordane
0.002
Dalapon
0.2
Dibromochloropropane (DBCP)
0.0002
Dinoseb
0.007
Dioxin (2,3,7,8-Tetrachlorodibenzo-p- dioxin) (1)(8)(7) Product: Every 3 years Source: Annually
3x10-8
Diquat (1)(8)(7)
0.02
Endothall (1)(8)(7)
0.1
| Endrin |
| ANNUALLY |
0.002
Ethylene dibromide
0.00005
| Glyphosate(1)(8)(7) |
| Product: Every 3 years |
Source: Annually
0.7
| Heptachlor |
| ANNUALLY |
0.0004
Heptachlor epoxide
0.0002
Lindane
0.0002
Methoxychlor
0.04
Oxamyl (vydate)
0.2
Pentachlorophenol
0.001
Picloram
0.5
Polychlorinated biphenyls (PCBs)
0.0005
Simazine
0.004
Toxaphene
0.003
MONITORING PARAMETER GROUP
| MONITORING FREQUENCY |
| FDA Standard of Quality (SOQ) Limits in mg/L (ppm) except as noted. |
Individual Group Analytes
| Additional Regulated Contaminants |
| ANNUALLY |
| Phenols (Total Recoverable Phenolics) |
| ANNUALLY |
0.001
1,1,2,2-Tetrachloroethane
NA
Microbiological Contaminants
| Total coliform / E. coli |
| SOURCE: at least once each week (21 CFR |
§129.35(a)(3))
PRODUCT: at least once each week (21 CFR
§129.35(g)(1))
MPN: <2.2
Organisms per 100 ml.
MF: <4 CFU per
100 ml.
| Radiological Contaminants |
| SEE BELOW |
| Gross Alpha Particle Radioactivity |
| SOURCE: Every 4 years PRODUCT: Annually |
| 15 pCi/L |
Gross Beta Particle and Photon
Radioactivity (9)
50 pCi/L
| Radium 226/228 (combined) |
| SOURCE: Every 4 years |
PRODUCT: Annually 5 pCi/L
| Uranium |
| SOURCE: Every 4 years |
PRODUCT: Annually 0.030
| Water Properties |
| ANNUALLY |
| Color |
| ANNUALLY |
15 Units
Turbidity
5.0 NTU
'pH (10)
NA
Odor
3 T.O.N.
(1) Included in FDA's 9 contaminant regulations.
(2) Included in FDA's D/DBP rule.
(3) SOQ dependent upon temperature and other factors. Bottled water to which no fluoride is added shall not contain fluoride in excess of 1.4 milligrams per liter.
(4) SMCL = Secondary maximum contaminant level. SMCLs are guidelines established by the USEPA for use in evaluating aesthetic, non-health-related properties in water. SMCLs are not enforceable for public water systems.
(5) Mineral water is exempt from allowable level. The exemptions are aesthetically based allowable levels and do not relate to a health concern.
(6) If total chromium results are <0.005 mg/l (5 ug/l), then monitoring for hexavalent chromium is waived.
(7) No SOQs or MCLs established for individual trihalomethane contaminants. The sum of the 4 THMs is regulated as total trihalomethanes (TTHMs).
(8) FDA requires that the four synthetic organic chemicals (SOC) listed must be tested quarterly for four consecutive quarters for each type of finished bottled water (e.g., spring, purified, etc.). If none of the SOCs are detected, then once every three years for each type of finished product. If SOCs are detected, maintain monitoring for four consecutive quarters in each three-year period. New products and new companies must do an initial round of quarterly monitoring in the first year of operation.
(9) If the gross beta particle activity exceeds 50 pCi/1, an analysis of the sample must be performed to identify the major radioactive constituents present. Compliance (with § 141.16) may be assumed without further analysis if the average annual concentration of gross beta particle activity is less than 50 pCi/1 and if the average annual concentrations of tritium and strontium–90 are less than those listed in table A, Provided, That if both radionuclides are present the sum of their annual dose equivalents to bone marrow shall not exceed 4 millirem/year. Consult with your testing laboratory for more information.
(10) The Code of Practice guideline for pH in purified water is 5.0-7.0 (see Appendix B for definition and requirements for purified water). The guideline for source water and other product waters is 6.5-8.5. NOTE: This guideline is not enforceable.
QUALITY ASSURANCE REQUIREMENTS FOR BOTTLED WATER
DATED 01 February 2018
File details come from the government source that posted it.