This file contains proposed changes to the Military Specification MIL-O-37997 for filled oxygen USP cylinders, specifically addressing the 95-gallon (size D) and 1,650-gallon (size H) Type I-DOT 3AA steel configurations. The document serves as an attachment to a Request for Information (RFI) issued by the Defense Logistics Agency Troop Support Medical for medical gas cylinders, including oxygen and nitrous oxide products in various sizes and capacities. The specification changes detailed in this attachment establish updated requirements and modifications that vendors must comply with when manufacturing these filled cylinders for potential government procurement.
The RFI seeks information from sources currently capable of manufacturing or distributing Type I-DOT 3AA steel medical gas cylinders meeting the specified military standards. Respondents are required to provide the source and part number, place of manufacture, medical gas source, current unit sale prices for prefilled cylinders, and estimated annual production capacity for each cylinder type and medical gas combination. All submitted information will remain the property of the U.S. Government, be kept confidential, and will be used by DLA Troop Support to develop procurement and planning strategies. This is a pre-solicitation notice, and the government has not committed to issuing a formal solicitation, making an award, or reimbursing response costs.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 6505-00-132-5199_O2-1650 Gal_Changes.docx | DOCX document | |
| MIL-O-37997_Oxygen Gas.pdf | ||
| MIL-N-37996_Nitrous Oxide Gas.pdf | ||
| 6505-00-130-1920_Nitrous Oxide_Changes.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OXYGEN,TECHNICAL
PHYSICAL FORM GAS SUPPLIED AMOUNT 95.000 GALLONS OXYGEN TRANSPORT D CYLINDER SPECIAL FEATURES 95 GALLON SUPPLEMENTARY FEATURES D-DAY ITEM FOR DOD; FOR SUPPORTING BASE ORDER 8120-00-664-0855; FOR YOKE ADAPTER ORDER 8120-00-550-8484; FOR D SIZE CYLINDER VALVE SHUT-OFF WRENCH,ORDER REPAIR PART ITEM 5120-00-097-4136
SHALL BE IN ACCORDANCE WITH MIL-O-37997 DATED
18 DECEMBER 1985 EXCEPT AS FOLLOWS:
PARA. 2.1.1., UNDER "STANDARDS MILITARY" DELETE
ALL REFERENCE TO RR-C-901/3.
PARA. 2.1.1, UNDER "STANDARDS MILITARY" DELETE
ALL REFERENCE TO MIL-STD-105 AND MIL-STD-129.
ADD THE FOLLOWING:
"OTHER MILITARY
. "MEDICAL MARKING STANDARD NO. 1"
PARA. 2.1.2, UNDER PUBLICATIONS, DELETE
"TM-38-250" AND SUBSTITUTE "DLAI 4145.3".
UNDER 2.2, ADD THE FOLLOWING:
"ASTM INTERNATIONAL
. "D 1974 - STANDARD PRACTICE FOR METHODS OF
. CLOSING, SEALING AND REINFORCING
. FIBERBOARD BOXES
. "D 5118 - STANDARD PRACTICE FOR FABRICATION
. OF FIBERBOARD SHIPPING BOXES
"(APPLICATION FOR COPIES SHOULD BE ADDRESSED TO
ASTM INTERNATIONAL, 100 BARR HARBOR DRIVE, WEST
CONSHOHOCKEN, PA 19428-2959, WWW.ASTM.ORG.)
"AMERICAN NATIONAL STANDARDS INSTITUTE
. "ANSI/ASQ Z1.4 - SAMPLING PROCEDURES AND
. TABLES FOR INSPECTION BY
. ATTRIBUTES
"(APPLICATION FOR COPIES SHOULD BE ADDRESSED TO
THE AMERICAN NATIONAL STANDARDS INSTITUTE, 11
WEST 42ND STREET, NEW YORK, NY 10036-8002.)"
PARA. 3.2.1 DELETE "AND FEDERAL SPECIFICATION
SHEET RR-901/3".
RENUMBER EXISTING PARA. 3.2.3 TO 3.2.3.1 AND
EXISTING PARA. 3.2.3.1 TO 3.2.3.2 AND ADD THE
FOLLOWING NEW PARA. 3.2.3:
"3.2.3 MARKING. CYLINDERS SHALL BE PERMANENTLY
MARKED BY STAMPING ON THE SHOULDER OF EACH
CYLINDER. THE MARKINGS SHALL BE NOT LESS THAN
3/16 INCH HIGH FOR CYLINDERS LESS THAN 6 INCHES
IN OUTSIDE DIAMETER AND NOT LESS THAN 3/8 INCH
HIGH FOR CYLINDERS MORE THAN 6 INCHES IN OUTSIDE
DIAMETER. IN ADDITION, EACH CYLINDER SHALL BE
PERMANENTLY MARKED WITH THE CLEAN AIR STAR IN
ACCORDANCE WITH 49 CFR, PARA. 173.34."
IN RENUMBERED PARA. 3.2.3.1 SPECIAL MARKINGS,
DELETE "DELETE FIRST SENTENCE ("CYLINDERS...
RR-C-901/3.") LINE 5, DELETE "POTENCY - 60
MONTHS" AND SUBSTITUTE "FILL DATE"; LINE 8,
DELETE "EXPIRATION DATE" AND SUBSTITUTE "FILL
DATE".
NOTE: THERE SHALL BE NO EXPIRATION DATING
ANYWHERE ON THE CYLINDER. THIS INCLUDES ANY
LABEL ON THE CYLINDER.
PARA. 3.3.1.1 DELETE THE WORD "EACH" IN LINES 3
AND 5 AND REPLACE WITH THE WORD "THE".
PARA 3.3.11 DELETE "MIL-V-2/42" AND SUBSTITUTE
"MIL-DTL-2/42" AND DELETE "MIL-V-2/41" AND
SUBSTITUTE "MIL-DTL-2/41".
IN PARA 4.3 INSPECTION DELETE MIL-STD-105 AND
SUBSTITUTE "ANSI/ASQ Z1.4".
IN SECTION 5, DELETE PARAGRAPHS 5.1 THROUGH
5.2.3 ENTIRELY AND SUBSTITUTE THE FOLLOWING:
"5.1 PRESERVATION. PRESERVATION SHALL BE
MILITARY, AS SPECIFIED (SEE 6.2).
"5.1.1 MILITARY.
"5.1.1.1 UNIT. EACH (EA). ONE FILLED CYLINDER,
AS SPECIFIED, CONSTITUTES ONE UNIT.
PRESERVATIVES SHALL NOT BE APPLIED TO ANY PART
OF THE CYLINDER.
"5.1.1.1.1 CYLINDERS 30 INCHES OR GREATER IN
LENGTH. UNIT PACKAGING IS NOT REQUIRED.
"5.1.1.1.2 CYLINDERS UNDER 30 INCHES IN LENGTH.
EACH CYLINDER SHALL BE PACKAGED IN A
BOX CONFORMING TO ASTM D 5118, CLASS DOMESTIC,
STYLE OPTIONAL. CLOSURE SHALL BE AS SPECIFIED
IN ASTM D 1974, CLOSURE METHOD 1F.
"5.2 PACKING. PACKING SHALL BE LEVEL A OR B,
AS SPECIFIED (SEE 6.1).
"5.2.1 LEVEL A.
"5.2.1.1 CYLINDERS 30 INCHES OR GREATER
IN LENGTH. CYLINDERS OF ONE SIZE AND TYPE ONLY
SHALL BE PALLETIZED ON 4-WAY ENTRY PALLETS, 40
INCHES LONG BY 48 INCHES WIDE. MIL-HDBK-774 MAY
BE USED AS A GUIDE FOR PALLETIZATION. RECOMMEND
LOAD TYPE IX BE USED; IN ADDITION, STRAPPING
SHALL BE ZINC-COATED.
"5.2.1.2 CYLINDERS UNDER 30 INCHES IN
LENGTH. CYLINDERS SHALL BE PACKED IN BOXES
CONFORMING TO PPP-B-601, OVERSEAS TYPE, STYLE I
OR STYLE J, OR PPP-B-621, CLASS 2. EACH WOOD BOX
SHALL BE LINED WITH A CASE LINER CONFORMING TO
MIL-L-10547. CLOSURE AND SEALING SHALL BE AS
SPECIFIED IN THE LINER SPECIFICATION. EACH WOOD
BOX SHALL BE CLOSED AND STRAPPED AS SPECIFIED IN
THE APPLICABLE BOX SPECIFICATION.
"5.2.2 LEVEL B.
"5.2.2.1 CYLINDERS 30 INCHES OR GREATER IN
LENGTH. CYLINDERS SHALL BE PALLETIZED AS
SPECIFIED IN 5.2.1.1.
"5.2.2.2 CYLINDERS UNDER 30 INCHES IN
LENGTH. CYLINDERS SHALL BE PACKED IN BOXES
CONFORMING TO PPP-B-601, DOMESTIC TYPE, OR
PPP-B-621, CLASS 1. CLOSURE SHALL BE AS
SPECIFIED IN THE APPLICABLE BOX SPECIFICATION.
"5.2.3 UNITIZED LOADS. CYLINDERS SHALL BE
UNITIZED AS SPECIFIED HEREIN AND IN THE CONTRACT
OR ORDER.
"5.3 MARKING.
"5.3.1 UNIT. EACH CYLINDER SHALL BE MARKED IN
ACCORDANCE WITH THE FEDERAL FOOD, DRUG AND
COSMETIC ACT AND REGULATIONS PROMULGATED
THEREUNDER, AND AS SPECIFIED IN PARA. 3.2.3.
MARKING SHALL INCLUDE THE NATIONAL STOCK NUMBER
(NSN), LOT (CONTROL) NUMBER, AND FILL DATE.
EXPIRATION DATE SHALL NOT APPEAR IN ANY MARKINGS.
"5.3.2 EXTERIOR (SHIPPING) CONTAINER AND
UNITIZED LOAD. EACH EXTERIOR (SHIPPING)
CONTAINER AND UNITIZED LOAD SHALL BE MARKED AS
SPECIFIED IN MEDICAL MARKING STANDARD NO. 1.
MARKING SHALL INCLUDE THE LOT (CONTROL)
NUMBER AND FILL DATE.
EXPIRATION DATE SHALL NOT APPEAR IN ANY MARKINGS."
IN SECTION 6, PARAGRAPH 6.2.1, DELETE SUBPARA-
GRAPH F ENTIRELY.
DELETE PARAGRAPH 6.4 ENTIRELY AND SUBSTITUTE:
"NATIONAL STOCK NO. ITEM IDENTIFICATION
"6505-00-132-5181 OXYGEN, USP, FILLED SIZE D
. CYLINDER, 95 GAL
"6505-00-132-5199 OXYGEN, USP, FILLED SIZE H
. CYLINDER, 1650 GAL
"6505-00-132-5225 OXYGEN, USP, FILLED SIZE M
. CYLINDER, 750 GAL"
IN FEDERAL SPECIFICATION RR-C-901, PARAGRAPH 3.10
COMPONENTS. LAST SENTENCE DELETE "AND D". ADD
"ALL SIZE D MEDICAL CYLINDERS SHALL BE PROVIDED
WITH A NECK FLANGE AND A CAP IN ACCORDANCE THE
THE REQUIREMENTS OF 3.10.1 AND 3.10.2."