JEFO - Hamilton C6_Final_Redacted.pdf
PDF 128 KB Posted
- Attached to
- Hamilton C-6 Ventilator Package
- Solicitation number
- SPE2D5-25-F-689A
About this file
This document is a Justification for an Exception to Fair Opportunity (JEFO) for the Defense Logistics Agency (DLA) Troop Support, Medical Supply Chain. The procurement is for twelve (12) Hamilton-C6 Ventilator Packages for the Landstuhl Regional Medical Center in Germany, with a total estimated value redacted. The ventilators are specifically required to support patients who cannot breathe independently, with detailed minimum requirements including pressure management, multiple patient mode capabilities, lung protection, patient monitoring, and integration with MHS Genesis.
Extensive market research was conducted by the US Army and DLA, which determined the Hamilton C6 ventilator is the only product meeting all specified requirements. The ventilators will be purchased under Hamilton Medical, Inc.'s existing PMCE contract SPE2D119D7009, with pricing previously determined fair and reasonable. The document notes that DLA Troop Support will continue monitoring other medical ventilator vendors for potential future alternatives, but currently, the Hamilton C6 is the sole product satisfying the government's comprehensive ventilation needs across adult, pediatric, and neonatal patient populations.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JUSTIFICATION FOR AN EXCEPTION TO FAIR OPPORTUNITY (JEFO)
LANDSTUHL REGIONAL MEDICAL CENTER
(1) The Defense Logistics Agency (DLA) Troop Support, Medical Supply Chain, Capital Equipment Division, is the contracting authority.
The action submitted for approval is a JEFO for an acquisition from Hamilton Medical, Inc. under PMCE contract SPE2D119D7009.
(2) This acquisition is for the purchase of twelve (12) HAMILTON-C6 VENTILATOR PACKAGE for Landstuhl Regional Medical Center in Landstuhl, Germany which is a part of the US Army Medical Command.
Manufacturer Part Number: 160021 Supplier Part Number: 160021 Product Description: HAMILTON-C6 VENTILATOR PACKAGE Quantity: 12 Unit Price:
The total estimated dollar value of this action is .
(3) The authority waiving the competition requirements is FAR16.505(b)(2)(i)(B) only one source is capable of providing the supplies or services required at the level of quality required because the supplies or services ordered are unique or highly specialized. The Hamilton C6 Ventilator identified above is the only product available on that can meet the US Army's minimum requirements.
US Army personnel have identified a need to procure mechanical ventilators. Mechanical ventilation is required for the patient population that cannot breathe on their own. Ventilators are used to deliver high concentrations of oxygen into the lungs. This could result from many factors that may include protecting the airways due to a neurologic cause, respiratory failure, premature birth or surgical procedures. The minimum requirements established for the ventilators by the US Army are as follows:
Pressure Management Pressure Controller
Modes for adult, pediatric, and neonatal patients.
built in lung protection Single, easy to read screen with patient monitoring data showing ventilation status.
Lung assessment and recruitment Automatic cuff pressure control Transpulmonary pressure measurement high flow oxygen therapy Pulse oximetry Serial interface for connection to PDMS or patient monitors Integration with MHS Genesis
Mainstream (volumetric) and side stream capnography On-screen help for alarm troubleshooting Mobile cart with Narrow footprint for use during patient movement between hospital locations and cart basket
US Customization Humidifier Holder O2 Cylinder Holder Neonatal Application nCPAP-PS Application High Flow O2 Therapy Application
CO2 SENSOR
Flow Sensor, infant Flow Sensors, Pediatric Flow Sensors, Adult Water Bag Pole
Positioning Support Arm 220V 50hz power compatible or dual voltage.
The HAMILTON-C6 ventilators are for intensive care ventilation of adults, pediatric, and optionally infants as well as neonatal patients. The main area of use is in a hospital setting. In addition, the HAMILTON-C6 are also designed for transfer of ventilated patients within the hospital. The products feature an integrated monitor with touch screen display and integrated alarm lamp; ventilation unit for gas mixing and control;
and patient breathing circuit for gas delivery and exchange. In addition, oxygen monitoring and connectivity to other sensors, devices, and external data interfaces are available. The ventilators consolidate the monitoring data and display it in intuitive graphics. These graphics provide a quick overview of the patients’ current ventilation status and provide a reliable basis for therapy decisions. It shows tidal volume, lung compliance, resistance, and patient efforts/triggers all in real time.
Currently the only ventilator on the market that meets these requirements is the Hamilton C6 ventilator supplied by Hamilton Medical, Inc.
(5) The Hamilton ventilators that are required are available on Hamilton’s PMCE contract SPE2D119D7009. The contract pricing has previously been determined fair and reasonable via comparison with commercial pricing, invoices, and other than certified cost or pricing data. In view of this earlier determination, the Contracting Officer has determined that the anticipated cost will be fair and reasonable to the Government, and that the subject procurement represents the best value to the government.
(6) Extensive market research has been performed by the US Army and validated by Defense Logistics Agency (DLA) personnel. Market research consisted of online product research, contacting ventilator manufacturers, accessing market research tools such as Emergency Care Research Institute (ECRI), and reviewing ECAT offerings for comparable alternatives. This research identified the following competitors as alternative solutions to the government’s requirements:
(7)There are no other facts supporting the use of this JEFO. DLA Troop Support will continue to monitor other Medical Ventilator vendors as they may have the capability to satisfy the government’s minimum requirements.