Space drawings for Cage Rack Washer.pdf
PDF 594 KB Posted
- Solicitation number
- 36C24E26Q0091
About this file
This is a technical engineering drawing and specification document for an SW6000 series industrial parts washer with steam capability and no side tanks. The machine is configured with specific interior dimensions of 48 inches left-to-right, 88 inches top-to-bottom, and 128 inches front-to-back, and operates on 480-volt, 20-amp, 3-phase electrical supply. The document provides detailed site condition requirements and installation specifications.
The washer requires multiple utility connections including: 1-inch NPT hot water supply at 40-60 PSIG (300 gallons per cycle), 1.5-inch NPT steam supply at 40-60 PSIG (420 pounds per cycle), 3/4-inch NPT condensate connections for both heat exchanger and sump heater, 2-inch NPT drain/overflow rated for 315 GPM, 1/4-inch NPT compressed air at 80 PSIG, 8-inch by 13-inch exhaust vent at the soiled end (600-1,200 CFM recommended), 8-inch by 22-inch breather vent at clean end (500 CFM), 1-inch NPT drain cooldown at 60 degrees Fahrenheit maximum, and a 12-inch by 12-inch by 8-inch deep floor sink with 4-inch dedicated waste pipe. The machine has a crated shipping weight of 63,500 pounds, heat loss of 34,000 BTUs per hour, operating sump capacity of 90 gallons, and can be shipped in 5 standard splits. The document includes a comprehensive site condition checklist covering hot/cold water, steam, condensate removal, electrical, exhaust ductwork, pit configuration, ceiling height, door clearances, and pathway access requirements for installation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24E26Q0091_1.docx | DOCX document | |
| 36C24E26Q0091.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISO VIEW
PIT OUTLINE
139" IM PIT
136 5
32 " OA SUMP PAN 8 3
32 " RAMP 8 3
32 " RAMP
63 5 32 "
OA
SUMP
PAN
87"
IM
PIT
PLAN VIEW
SOILED
SIDE
8 9
CLEAN
SIDE
BUILD DRAWING
FOR MARKUP OR APPROVAL
Site condition check list:
- Hot & cold water rough ins
- Steam rough ins
- Condensate removal / return
- Floor sink & building drain size
- Compressed air rough in
- Electrical rough in
- Exhaust duct rough in ( All welded ss duct, sloped back to washer recommended. )
- Breather vent containment ( vent hood recommended. No direct connection )
- Pit configuration is correct
- Ceiling height & wall clearances
- Door swings are clear & correct
- Pathways for entry of washer into building ( A non-standard split of washer may be required )
- Washer interior sizes are correct:
- 48" - Clear - Left to right
- 88" - Clear - Top to bottom
- 128" - Clear - Front to back
SIGNED:
DATE:
132 5
32 " OVER BODY
94 5 16 "
F.F.F.
12 13 16 "
112 21 32 "
TO DUCT
CONNECTION
8" 9 9 16 " 88 3
8 " 8"
GENERAL NOTES & RECOMMENDATIONS:
-All services to Washer ( by others ) must comply with applicable local codes and practices regarding final connections, responsibility herein lies with installation company,and not equipment manufacturer.
-Supply lines to be sized larger than utilities shown to ensure adequate service.
-All connection lines to be provided with appropriate shut offs, connections, & regulators.
-Range indicates minimum/maximum pressures, if supply exceeds maximum, provide a regulator and or pressure release valve prior to connection with machine ( by others ) -Electrical supply should be connected with sealtite flex and a fused panel box.
- If condensate lift is required, a condensate pump is recommended.
15 HP PUMP
MOTOR
NOTE: PIT NOT SHOWN
FINISHED
FLOOR LEVEL
SERVICE SIDE VIEW
SOILED
SIDE
CLEAN
SIDE
75 9 32 "
48"
CLEAR
INSIDE
88 1 2 "
CLEAR
INSIDE
RH HINGE
WINDOW
CLEAN SIDE
CONTROL PANEL
CLEAN SIDE VIEW
14 1 4 "
PIT
DEPTH
93 29 32 "
LH HINGE
USER
INTERFACE
SCREEN
EMERGENCEY
STOP
BUTTON
MAIN
DISCONNECT
WINDOW
PIT
OUTLINE
FINISHED
FLOOR LEVEL
SOILED SIDE VIEW
See pit drawing for pit configuration
SW6000 - Service Requirements & Engineering Data - Steam - No Side Tanks Machine Electrical Draw - 480 Volt - 20 Amp - 3 Ph
CHK. # SERVICE CONNECTIONS DYNAMIC PRESSURE RANGE PEAK FLOW RATES AVERAGE CONSUMPTION X 1 HOT WATER 1" NPT - 120 DEG F / 49 DEG C 40-60 PSIG / 267-414 KPA 25 GPM / 95 LPM 300 G/CYCLE / 1136 L/CYCLE
2 STEAM 1 1/2" NPT 40-60 PSIG / 276-414 KPA 885 LBS / HR / 401 KG / HR 420 LBS / CYCLE / 191 KG /
CYCLE
X 3 CONDENSATE - HEAT EXCHANGER 3/4" NPT 1.9 GPM / 7.0 LPM
X 4 CONDENSATE - SUMP HEATER 3/4" NPT 1.0 GPM / 3.8 LPM
X 5 DRAIN / OVERFLOW 2" NPT 315 GPM / 1193 LPM
X 6 AIR 1/4" NPT 80 PSIG / 552 KPA 1 CU. FT/HR / .03 CU M/HR
X 7 ELECTRICAL 1/2" KO @ CONTROL BOX
X 8 EXHAUST VENT @ SOILED END 8" X 13" - DIRECT CONNECTION .5 SP "WG / .13 KPA 600 -1200 CFM 1200 CFM RECOMMENDED
X 9 BREATHER VENT @ CLEAN END 8" X 22"- (EXHAUST HOOD REQD. ABOVE) .25 SP "WG / .07 KPA 500 CFM / 14.2 M3/MIN
X 10 DRAIN COOLDOWN 1" NPT - 60 DEG F / 16 DEG C MAX 30-60 PSIG / 207-414 KPA 25 GPM / 95 LPM 106 G/CYCLE / 401 L/CYCLE
X 11 FLOOR SINK DRAIN 12"X12"X8" DP 4" WASTE PIPE - DEDICATED (RECOMMENDED) 600 GPH / 2271 LPH
Miscellaneous Engineering Data
CRATED SHIPPING WEIGHT 63500 LBS / 2600 KGS
NO. OF SPLITS 5 ( STANDARD )
HEAT LOSS 34,000 BTU`S / HR
OPERATING SUMP CAPACITY 90 GALS US
D
E
F
C
1 2 3 4
B
A
C
D
A
B
A3
SHEET/DRAWING #:SCALE:
FAB
PART #:
TITLE:
REVISION:DO NOT SCALE DRAWING
DATESIGNATURENAME
DEBURR AND
BREAK SHARP
EDGES
JOB #:UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
LINEAR: 1/32 "
ANGULAR: .5 Deg.
Q.A
MFG
APPV'D
CHK'D
DRAWN
SERIAL #:
E
SW6700-PT-RH-STM- QLNOV 30 22
WEIGHT:
Gulshan
NOTE: ALL LAYOUT DRAWINGS ARE - GOOD SIDE OF MATERIAL UP INVENTORY #:
87654321
XXXXX
CUSTOMER:
PROJECT:
PRELIMINARY
PRELIMINARY
E:\Solidworks Washers\6000 WASHERS\6000- JOB FILES\XXXX- PRELIMINARY- SW6700-PT-RH-STM 48X88X128\XXXX-PRELIMINARY-SW6700-PT-RH-STM-480V- 48X88X128
XXXXX
XXXX
| Sheet1 |
| Drawing View6 |
| Drawing View8 |
| Drawing View7 |
| Drawing View9 |
| Drawing View10 |
File details come from the government source that posted it. Updated .