This statement of work outlines requirements for load testing and inspection of overhead bridge cranes and a mobile crane at the Defense Distribution Depot Oklahoma City facility. The contractor will be required to perform annual load tests at 100-125% of rated capacity and provide certified weights, rigging and inspection reports. Quarterly inspections of the overhead 10-ton bridge crane are also required, examining safety items, electrical components, rail alignment, wire rope condition and other aspects. The contractor must furnish detailed reports and adhesive labels for the equipment. Repair estimates must be provided for any deficiencies found. The Defense Logistics Agency Distribution will be the accepting agency. Work will take place at specified locations at Tinker Air Force Base in Oklahoma City and must begin within 30 days of award, with a potential period of performance of up to 5 years.

View the file

Other files for this federal contract opportunity

Other files attached to Bridge Crane Load Test at DLA Distribution Oklahoma City, newest first.
File Type Posted
TAB 11 - Amendment 0001.pdf PDF
Tab 11 - CSS SP3300-24-Q-0041.pdf PDF
Attachment 2 - Wage Determination.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work (SOW) DDOO Oklahoma – Bridge Crane Load Test

Technical Assistant: James Carpenter Defense Distribution Depot Oklahoma City Building 1, Door 58 Tinker AFB, OK. 73145-8000

Phone: 405-855-044

Certifying Official: James Carpenter Defense Distribution Depot Oklahoma City Building 1, Door 58 Tinker AFB, OK. 73145-8000

Phone: 405-855-3044

Background:

a. Requiring Organization

Defense Distribution Depot Oklahoma City, Oklahoma (DDOO)

b. Purpose of the Statement of Work (SOW):

Requirements for performance of quarterly inspection of Overhead 10 ton Bridge Crane and yearly load test on the 10 ton Bridge Crane and 15ton Grove GCD15 mobile Crane located at DLA DDOO Bldg 812 Tinker AFB Oklahoma City.

Overhead 10 ton Bridge Crane Type: Bridge Capacity: 10 Tons Crane OEM: Handling Systems Crane Serial Number: 24034 Bridge Power Supply: 460V-3Ph-60Hz Control Type: Pendant & Remote Lifting Medium: Wire Rope Hoist OEM: R&M Hoist Serial Number: 10000599117 Hoist Model Number: SX50410100P55FDL0S Hoist Reeving: S4 Control Power Supply: 115V-1Ph-60Hz Height: Approximately 25ft

15ton Grove GCD15 mobile Crane Serial number: 322888 Capacity: 15 Ton Boom: three (3) section 41 ft GVW: 25,329 lb OEM: The Manitowoc Company, Inc

Statement of Work (SOW)

1. Scope of Work to be Performed: Load test 10 Ton Bridge Crane and 15 Ton Grove GCD15 Mobile Crane annually, perform quarterly inspection of Overhead 10 ton Bridge Crane

2. Description of Contractor’s Tasks:

Load test Annually

- Provide all management, qualified labor, tools, and supplies, except as specified in section 7 Government Furnished Property/Equipment, to perform pre-test inspections, load tests and post-test inspections in accordance with CMAA Specification 78, section 4.7

-Provide certified weights and rigging.

-Perform pre-test inspection of 10 Ton Bridge Crane and 15 Ton Grove GCD15

Mobile Crane.

-Perform load tests at not less than 100% capacity and not more than 125% of rated capacity.

-Perform post-test inspection of 10 Ton Bridge Crane and 15 Ton Grove GCD15

Mobile Crane.

-Furnish detailed report of inspection and load test results and adhesive label to include equipment identifying information, test dates, test type, load applied, results and certification of load test, adhere label to equipment.

-Load test may be performed in conjunction with a quarterly inspection.

Crane Inspection Quarterly

-Provide all management, qualified labor, tools, and supplies, except as specified in section 7 Government Furnished Property/Equipment, necessary to inspect and certify a 10 Ton Bridge Crane in accordance with applicable OSHA and ASME regulations, particularly OSHA 1910.179 and ASME B30.2-2011.

-Inspections must include the following items, at minimum: Safety items, Electrical components, Rail alignment and support, Wire rope condition, Hook and Latch, Drives and gear boxes.

-Furnish detailed report of inspection results and adhesive label to include equipment identifying information, test date, test type, results and certification of inspection, adhere label to equipment.

-Provide detailed repair estimate for deficiencies identified during the inspection.

-All repair work must be authorized by a DLA supervisory representative prior to repair work starting.

3. Certification and Acceptance:

Final acceptance of the attachment results will be James Carpenter.

4. Project Management Approach:

N/A

5. Performance and/or Delivery Schedule:

6. Work Location(s) and travel:

Defense Logistics Agency Defense Distribution Center, Oklahoma City 7250 59th Street Building 812 Tinker, AFB, OK. 73145-8000

DODAAC: SB3212

Travel to other locations is not required.

7. Government Furnished Property/Equipment:

The Government will provide 120V power source at facility, escort or badges to access facility.

8. Security Requirements:

Contractor shall comply with DDOO security requirements for on-site access for personnel and vehicles if necessary.

9. Period of Performance:

Work shall begin 30 days after Contract is awarded, for up to 5 years.