NCR SelfServ 32, 34 and 38 ATMs Site Preparation Requirements
B006-6670-B000
TM
Attachment 2
FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO FREQUENCY
INTERFERENCE STATEMENT
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Canadian Class A Device Declaration
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
Information to User
This equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no guarantee that interference to radio communications will not occur in a particular commercial installation. If this equipment does cause interference, which can be determined by turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately.
CAUTION
NCR Corporation is not responsible for any radio or television interference caused by unauthorised modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR. Such unauthorized modifications, substitutions, or attachments may void the user’s authority to operate the equipment. The correction of interference caused by such unauthorized modifications, substitutions, or attachments will be the responsibility of the user.
The product described in this book is a licensed product of NCR Corporation.
NCR, Personas and NCR SelfServ are trademarks of NCR Corporation. Other product names mentioned in this publication may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available.
NCR, therefore, reserves the right to change specifications without prior notice.
All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current.
© 2008 By NCR Corporation, Dayton, Ohio U.S.A.
www.ncr.com All Rights Reserved www.ncr.com
Table of Contents
NCR SelfServ 32, 34 and 38 ATMs Site Preparation Requirements
INTRODUCTION
ENVIRONMENTAL REQUIREMENTS
Temperature and Humidity
Normal Operating Range Storage Range (Up To Three Months):
Transit Range (Up To One Week):
Extreme Power On Range (Up To One Hour):
Barometric Pressure Electromagnetic Compatibility (EMC) and Safety
EMC Directives Emission Standards Additional Requirements for 220V - 240V Units Immunity Standards Safety Directive Harmonised Safety Standard
Acoustics Heat Dissipation
POWER REQUIREMENTS: SELFSERV 38 ONLY
AC Power Requirements Input Voltage Setting AC Wiring Details Power Cable
AC Distribution Wiring Diagram Grounding Requirements Transient Power Loss Third Party Surround/Topper Wiring
Customer Responsibilities NCR Responsibilities Recommended Wiring When Wiring Cannot be Routed Externally B006-6670-B000 i
POWER REQUIREMENTS: SELFSERV 32 AND 3413
AC Power Requirements Input Voltage Setting Power Cable Grounding Requirements
COMMUNICATIONS REQUIREMENTS
High Order Communications Standard Cable (RS-232) Remote Device Cables
RS-232 Cable (9 pin) (not applicable to SelfServ 38 ATMs) Remote Status Monitor Alarm Interface Cable Remote Relay Cable Ethernet Standard Cable
AC POWER AND DATA LINE TRANSIENT PROTECTION
AC Power Line Transient Protection Data Line Transient Protection Power Protection Products NCR Site Preparation Services Contact Information
PLANNING CHECK LIST
ii B006-6670-B000
NCR SelfServ 32, 34 and 38 ATMs Site Preparation Requirements Table of Contents
NCR SelfServ 32, 34 and 38 ATMs Site Preparation Requirements
INTRODUCTION
This book, which is part of the SelfServ 32, 34 and 38 ATMs Site Preparation booksets, provides environmental, power, communications and protection requirements for the range of ATMs. It also provides a planning checklist for site preparation activities and NCR Site Preparation Services contact details.
B006-6670-B000 1
ENVIRONMENTAL REQUIREMENTS
For the ATMs to function correctly, the site at which they are to be installed should meet the following environmental requirements.
Temperature and Humidity The ATMs will operate over a range of temperature and humidity. However, continuous operating at or near the range limits or in a location where the temperature and humidity change beyond the specification, should be avoided. The temperature and humidity ranges are as follows:
Normal Operating Range
Refer the appropriate environment(s) below for the ATM to be installed. Note that the site of an ATM to be installed through an exterior wall must meet the requirements of both the Interior and Exterior (through the wall) environments.
Note 1: If severe environment is fitted, the minimum temperature is 0°C (32°F).
Note 2: For Through the Wall ATMs, the humidity inside the building is restricted to a maximum of 30% at an outside temperature of -35°C (-31°F), with a linear relationship between temperature and humidity to a maximum humidity at 0°C (32°F).
Note 3: If a passbook printer is fitted, the minimum exterior temperature is 0°C (32°F) and the maximum relative humidity is 80%.
Interior Environment Exterior Environment
Lobby & Through the Wall ATMs
Through-the-Wall ATMs Freestanding Drive-Up ATMs
Temperature (dry bulb)
10°C to 40°C (50°F to 104°F) See Note 1.
-35°C to 50°C (-31°F to 122°F) See Note 3.
Without air conditioning:
-35°C to 45°C (-31°F to 113°F)
With air conditioning:
-35°C to 50°C (-31°F to 122°F)
Relative humidity
20% to 80% See Note 2.
10% to 100% See Note 3.
10% to 100%
Dew point temperature restriction
26°C (79°F) max. 26°C (79°F) max. 26°C (79°F) max.
2 B006-6670-B000
Storage Range (Up To Three Months):
Transit Range (Up To One Week):
Extreme Power On Range (Up To One Hour):
Barometric Pressure
Electromagnetic Compatibility (EMC) and Safety The ATMs comply with the following directives and standards for IT equipment:
EMC Directives
● 2004/108/EC ‘EMC Directive and Amendments’
● 93/68/EEC ‘CE Marking Directive’
Emission Standards
The ATMs comply with the following requirements for radiated and conducted emissions:
● EN 55022 (1998) Class A
● FCC 47CFR Part 15. Class A
● CISPR 22 Class A
● AS/NZS 3548 Class A
● GB 9254 Class A
● CNS 13438 Class A.
Temperature -10oC to 50oC (14oF to 122oF)
Relative Humidity 10% to 90%
Temperature -40oC to 60oC (-40oF to 140oF)
Relative Humidity 5% to 95%.
Temperature 0oC to 45oC (32oF to 113oF)
Relative Humidity 10% to 95%.
Operating and transit limits 105 kPa (15.2 lb. F/in.) to 70 kPa (10.2 lb. F/in.)
Equivalent altitude Up to a maximum of 3000 m (9842.52 ft).
B006-6670-B000 3
Additional Requirements for 220V - 240V Units
The ATMs comply with the following requirements for conducted emissions:
● EN 61000-3-2: 2000, Mains harmonics, Class A
● EN 61000-3-3: 1995/+A1: 2001, Mains flicker.
Immunity Standards
The ATMs comply with the following requirements for radiated and conducted immunity:
● EN 55024 (1998)/+A1: 2001, A2: 2003
As per the requirements of EN55024, the ATMs comply with the requirements of the following normative Immunity Standard:
● EN 61000-4-2 Electrostatic Discharge
● EN 61000-4-3 Radiated RF
● EN 61000-4-4 Electrical Fast Transient/Burst
● EN 61000-4-5 Surge
● EN 61000-4-6 Conducted RF
● EN 61000-4-8 Power Frequency Magnetic Field
● EN 61000-4-11 Voltage Dips/Short Interruption.
Safety Directive
● 73/23/EEC, 93/68/ECC ‘Low Voltage Directive and Amendment’.
Harmonised Safety Standard
● EN 60950-1: 2006 ‘Information Technology Equipment - Safety’
● EN 60950-22: 2006 ‘Information Technology Equipment - Safety. Equipment Installed Outdoors’ (SelfServ 38 only)
Acoustics The acoustics sound power does not exceed:
● 65dB(A) when idle
● 68dB(A) when operating (see note).
Note: The following configurations will affect the sound levels:
Configuration Acoustic sound power when operating
Coin and passbook does not exceed 72 dB(A)
Cooling fans does not exceed 75 dB(A)
Air conditioner does not exceed 78 dB(A) 4 B006-6670-B000
Heat Dissipation The NCR SelfServ product range is a flexible hardware platform. NCR recommends that actual power measurements are taken and used to establish the heat dissipation for specific hardware configurations. These measurements should include any custom or third party features.
Where specific measurements are not available then, as a guide, 760 KJ/hour can be used as an indicative heating load. This figure is based on an ATM in idle mode, with a medium to high feature functionality configuration.
Note: Heat dissipation figures are largely unaffected by transactional rates.
B006-6670-B000 5
POWER REQUIREMENTS: SELFSERV 38 ONLY
Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur, the use of protective devices, as described in this book, may be required to ensure proper operation of the equipment.
AC Power Requirements The maximum current requirements at the stated input voltages are:
● 30A at 120V
● 15A at 220V.
The maximum inrush current requirements at the stated input voltages are:
● 50A peak at 136V
● 80A peak at 257V.
Note 1: Power to the ATM is to be a dedicated 30A service.
Note 2: The ATM must comply with local code requirements and be protected with a 30A circuit breaker.
Note 3: For terminals with deposit devices, be aware that in the event of a power failure, there is the potential for customer’s cash to be retained in the device. For the reason, NCR does not recommend running an ATM with deposit devices without an Uninterruptible Power Supply (UPS).
Input Voltage Setting The ATM can operate from the following input mains voltages:
● 90V to 136V at 50/60Hz
● 198V to 257V at 50/60Hz.
6 B006-6670-B000
AC Wiring Details
Note 1: Building Ground - The insulated isolated ground wire for the system must not be connected to conduit, water pipe, or building steel, except at the point where the main building load centre is tied to ground. In some countries, neutral and ground may not be connected.
Note 2: Ground Bus - The distribution panel ground bus must be insulated from the distribution panel and the conduit.
Line1 Line 2
N L2 L1
Neutral and Ground Bus
Building Ground Point
Main Service Panel
Distribution Panel
Site Wiring NCR Equipment
Line
Disconnect Switch
Neutral
Isolated Ground/Earth
Isolated/Insulated Ground Bus
Neutral Bus
Note 1
Note 2
Note 3
Note 4
Surround Topper etc.
Note 5
Note 5
Note 6
NCR 6638 ATM
AC
Inlet B006-6670-B000 7
Note 3: Dedicated 30A Service - The NCR SelfServ 38 ATM must have a dedicated 30A service.
Note 4: Branch Circuits - The minimum size for branch circuit cables is 5.25 mm2 (10 AWG). The cables must have 3 insulated conductors. Each branch must have a separate branch circuit. Some countries do not use Line 2, in which case connect all branch circuits to Line 1.
Note 5: Other Circuits - For other units, use circuit breakers appropriate to the current draw as seen on the unit name plates.
Note 6: Distribution Panel - The distribution panel must be free of heavy start loads and other electrically noisy equipment (such as air conditioners, welders, and paper shredders). A dedicated panel is not required.
Power Cable The ATM is a fixed wire product and is not supplied with a power cable. The following illustrations indicate how the internal wiring of the ATM is connected to a dedicated 30A circuit via a terminal block connector.
WARNING
The cable used to connect to the ATM must have copper conductors and must comply with local code requirements.
WARNING
This equipment must be grounded (earthed).
8 B006-6670-B000
AC Distribution Wiring Diagram
Terminal Block
141516
5 4 3 2 1
131211
10 9
Surge Arrestor
Aircon Socket
MCB
(15A) x 2
L N E
ATM
400W Heater
UPS In
UPS Out o C therm
Heater 300W (2 off)
200W Heater
PSU1
PSU2
Dispenser PC Core
UPS
switch
Service Switch
Cabinet Heater
AC Inlet w ay S oc ke t
17181920 w ay S oc ke t
10 AWG =
16 AWG =
18 AWG =
PC Core
Thermostat
Media
Dispenser
(1 or 2 off)
Air Conditioner
Power Supply Unit (1 or 2 off)
300w Heater (2 off)
200w Heater
AC Distribution Box
Service Switch
Circuit Breakers
UPS
Power Switch
Isolation Switch B006-6670-B000 9
Grounding Requirements The ATM operates from a single phase, 3 wire supply; live, neutral and ground. The power requirements of this unit will normally permit it to operate within existing wiring configurations and from existing branch mains outlets providing:
1. Where the supply is provided from a general purpose distribution panel, then the other branch circuits from this panel must not be used to support heavy inductive loads such as air conditioners, elevators, microwave ovens, and so on. Nor may such equipment be operated on the same branch circuit as the ATM.
2. If using distribution panels, all branch circuit grounding conductors must be connected to an insulated terminal strip in the distribution panel. The grounding conductor from the distribution panel to the building ground point must be at least equal in size to the power conductor necessary to supply the NCR system.
Note: Specifically, the following grounding requirements must be provided:
● Isolated grounding for each NCR ATM.
● Insulated ground conductors to the building service ground point.
● Isolate the ground conductors from all conduit, panels and neutrals. The ground wire and neutral are tied together only at the building entrance, or a derived source such as a transformer.
● “IG” (isolated ground) receptacles. Do not tie the receptacle ground lug to the conduit, armoured cable sheathing, or building frame.
● Do not use a ground conductor for more that one branch circuit.
● All units in a power chain have their grounds connected through the power cables.
Note: The building ground point can affect data integrity. For additional information refer to the Data Line Transient Protection section of this book.
Transient Power Loss The voltage loss due to power interruptions must not be more than 50% of the nominal value for a maximum of one half cycle at a maximum rate of 1 every 10 seconds.
Third Party Surround/Topper Wiring The following information is for guidance only, when providing power to a third party surround/topper outside of the ATM.
It is the responsibility of the customer to make sure that all site preparations are complete and in compliance with NCR specifications and requirements and with all national, state or local electrical codes, telephone and telegraph regulations and laws.
10 B006-6670-B000
Customer Responsibilities
The customer must make sure of the following:
● Power is from a separate dedicated source and is not tapped into the ATM’s dedicated 30A circuit (which is required to provide power to the ATM only)
● Surround/topper, or other equipment, is not plugged onto the internal AC outlet or power bar (if fitted)
● If power is routed internally through the ATM, it is routed safely and securely and does not interfere with any internal module functions
Note: NCR recommends external routing.
● All applicable codes, regulations and laws (including but not limited to electrical, building, safety and health, disabilities) are met
● The environmental requirements of the system/unit are met.
CAUTION
The power cable must be connected by a certified electrician.
NCR Responsibilities
NCR Corporation is not responsible for any modifications or wiring of this equipment.
Such modifications may void the customer’s authority to operate the equipment. The correction of interference caused by such modifications will be the responsibility of the customer.
Recommended Wiring
It is recommended that power to the surround/topper be routed externally, outside of the ATM, ensuring all codes, regulations and laws are met. Electrical conduit may be attached to the outside of the ATM.
The power must be from a dedicated source separate from the ATM.
B006-6670-B000 11
The following illustrations show two examples of correct external wiring methods.
When Wiring Cannot be Routed Externally
Disclaimer: NCR is not liable for any additional third party wiring. It is important that the site be prepared by a customer who is fully conversant with the special requirements of the electronic and electrical equipment. The responsibility remains with the customer.
Topper Blank There is a topper blank plate fitted to the top of the ATM. This access point can be used for topper wiring subject to the disclaimer above.
See the NCR SelfServ 38 ATM Installation Guide (B006-6609) for details.
Power is routed externally from a dedicated source separate from the ATM 12 B006-6670-B000
POWER REQUIREMENTS: SELFSERV 32 AND 34
Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur, the use of protective devices, as described in this book, may be required to ensure proper operation of the equipment.
AC Power Requirements The maximum current requirements at the stated input voltages are:
● 10A at 120V
● 6.3A at 230V.
The maximum inrush current is 100A.
Note: For terminals with deposit devices, be aware that in the event of a power failure, there is the potential for customer’s cash to be retained in the device. For the reason, NCR does not recommend running an ATM with deposit devices without an Uninterruptible Power Supply (UPS).
Input Voltage Setting The ATM can operate from the following input mains voltages:
● 90V to 136V at 50/60Hz
● 180V to 264V at 50/60Hz.
Power Cable The ATM is supplied either as a 120V or a 220-240V unit. 120V ATMs are supplied with a power cable fitted with a NEMA type 5-15P power source connector. 220-240V ATMs are supplied with an unterminated power cable. Information about suitable power connectors is supplied with the accessories.
The power cable supplied is 3 m (9.8 ft) in length. If it is necessary to increase this length to meet site requirements, then the extension must satisfy local or country regulations.
Power connectors must be wired as shown below.
WARNING
This equipment must be earthed.
B006-6670-B000 13
Note: The annotations within brackets are included to comply with United Kingdom legislation and refer to the markings on United Kingdom three pin plugs.
Grounding Requirements The ATM operates from a single phase, 3 wire supply; live, neutral and ground. The power requirements of this unit will normally permit it to operate within existing wiring configurations and from existing branch mains outlets providing:
1. Where the supply is provided from a general purpose distribution panel, then the other branch circuits from this panel must not be used to support heavy inductive loads such as air conditioners, elevators, microwave ovens, and so on. Nor may such equipment be operated on the same branch circuit as the ATM.
2. If using distribution panels, all branch circuit grounding conductors must be connected to an insulated terminal strip in the distribution panel. The grounding conductor from the distribution panel to the building ground point must be at least equal in size to the power conductor necessary to supply the NCR system.
Note: The building ground point can affect data integrity. For additional information refer to the Data Line Transient Protection section of this book.
Live - Brown (L or Red)
(N or Black)
(E or Green/Yellow)
Neutral - Blue
Ground - Yellow/Green 14 B006-6670-B000
COMMUNICATIONS REQUIREMENTS
Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur, the use of protective devices, as described in this book, may be required to ensure proper operation of the equipment.
It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with NCR specifications and requirements and with all national, state or local telephone and telegraph regulations and laws.
Note: External communications cables are not supplied with the ATM. If these cables are required, it is the customer’s responsibility to have them installed. The specifications for these cables are supplied in the following sections. When producing cables allow for
2.2 m (7.2 ft) of cable within the ATM.
High Order Communications Standard Cable (RS-232) The type of cable required depends upon the communications system to be used.
The standard high order communications system supports most common bit and byte oriented disciplines (synchronous and asynchronous) with an RS-232 interface.
The interconnecting cable to the remote modem should not exceed 12.2 m (40.0 ft) in length (except SelfServ 38 which should not exceed 15.24 m (50.0 ft)), and must conform to the following specification:
B006-6670-B000 15
At the required point (see below) from the ATM end of the cable, remove a 40 mm (1.6 in.) section of the outer sleeve, taking care not to cut through the cable shielding.
Dimension SelfServ 38 SelfServ 32 and 34
A 1.6 m (5.2 ft) 1.5 m (4.9 ft)
CHASSIS GND
TD.V
RD.V
RQS.V
TSET.V
RFS.V
RSET.V
DSR.V
WCA.V
SIG.GND
DTR.V
EXT SET.V
RLSD.V
CI.V
WIN.V
1, 2 6 5
1. Connector, 25 way (NCR part no. 006-0005897).
2. Terminal wire, male (NCR part no. 009-0002642).
3. Cable, multiconductor (NCR part no. 007-8907033).
4. Connector (determined by remote device).
5. Shell hood (NCR part no. 006-1500038).
6. Screw retainer (NCR part no. 601-0101584).
3 4
40 mm (1.6 in.)
A
16 B006-6670-B000
Remote Device Cables The specifications for these external cables are supplied below.
RS-232 Cable (9 pin) (not applicable to SelfServ 38 ATMs)
The ATM can have up to two RS-232 (9 pin) outlets. The cable for each outlet is limited in length to 12.24 m (40.16 ft) and must conform to the specification and wiring given below.
At a point 2.2 m (6.6 ft) from the ATM end of the cable, remove a 40 mm (1.6 in.) section of the outer sleeve, taking care not to cut through the cable shielding.
DCD
DSR
RXD
TXD
DTR
S-GND
RTS
CTS
RI
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9
1. Connector, 9 way (NCR part no. 006-0010488).
2. Terminal wire, female (NCR part no. 009-0002640).
3. Cable, multiconductor (NCR part no. 007-8907033).
4. Connector (determined by remote device).
Shielding Shielding
1, 2 3 4
40 mm (1.6 in.)
2 m (6.6 ft) B006-6670-B000 17
Remote Status Monitor
The remote status monitor feature is supplied as a complete assembly and consists of a status indicator unit, 76.2 m (250 ft) of cable and a connector.
At the required point (see below) from the ATM end of the cable, remove the required amount of the outer sleeve, taking care not to cut through the cable shielding.
If you need to shorten the cable, proceed as follows:
1. Remove the cover from the remote status indicator unit.
2. Disconnect the four leads from the indicator, that is E1, E2, E3 and E4.
Dimension SelfServ 38 SelfServ 32 and 34
A 125 mm (4.9 in.) 20 mm (0.8 in.)
B 200 mm (7.9 in.) 40 mm (1.6 in.)
B
A
Red
(Green) E1
(Red) E2
(White) E3
(Black) E4
Yellow
Green 18 B006-6670-B000
3. Cut the cable to the required length and strip the four wire ends.
4. Connect the wires to the correct terminals.
5. Replace the status indicator cover.
Alarm Interface Cable
The ATM may optionally be configured to provide an alarm interface which enables the ATM to be connected to an external local alarm system. The interface may take the form of one of two options; a basic alarm system or an enhanced alarm system.
A stabilised, non interruptible, power supply must be provided through the external alarm system. The alarm interface cable wiring must conform to the following specification:
● 12V +/- 2V dc
● 200mA maximum
● Ripple, 5% maximum.
At the required point (see below) from the ATM end of the cable, remove the required amount of the outer sleeve, taking care not to cut through the cable shielding.
Dimension SelfServ 38 SelfServ 32 and 34
A 125 mm (4.9 in.) 20 mm (0.8 in.)
B 200 mm (7.9 in.) 40 mm (1.6 in.)
1. Connector, 25 Way (NCR part no. 006-0005896)
2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, multiconductor (determined by the alarm installed).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006- ).
6. Screw retainer (NCR part no. 601-0101584).
1500038
1,2 5 3 46
B
B006-6670-B000 19
Basic Alarm Interface Cable Wiring
Enhanced and High Security Alarm Interface Cable Wiring
CHASSIS GND
SILENT ALARM N.O. *
DOOR ALARM N.C..
VIBRATION/HEAT N.O.
SILENT ALARM COMMON *
SILENT ALARM N.C. *
VIBRATION/HEAT COMMON
VIBRATION/HEAT N.C.
DOOR ALARM N.O.
DOOR ALARM COMMON
+12V
+12V RETURN
* Optional
CHASSIS GND
DOOR ALARM N.O.
TAMPER ALARM N.C..
TEST TRANSMITTER A
SILENT ALARM COMMON *
TAMPER ALARM N.O.
+12V
TEST TRANSMITTER B
DOOR ALARM N.C.
TAMPER ALARM COMMON
DOOR ALARM COMMON
SILENT ALARM N.O. *
COMPOSITE ATTACK N.C.
COMPOSITE ATTACK N.O.
SILENT ALARM N.C. *
+12V RETURN
COMPOSITE ATTACK COMMON
* Optional 20 B006-6670-B000
Remote Relay Cable
The remote relay provides a pair of open contacts, rated at 28 volts per ampere for both ac and dc supplies, which can be closed to activate a remote device. The interconnecting cable to a remote device must conform to the following specification and wiring:
At the required point (see below) from the ATM end of the cable, remove the required amount of the outer sleeve, taking care not to cut through the cable shielding.
Dimension SelfServ 38 SelfServ 32 and 34
A 125 mm (4.9 in.) 20 mm (0.8 in.)
B 200 mm (7.9 in.) 40 mm (1.6 in.)
RL1
RL2
1, 2
1. Connector, 2 way Mate-N-Lock (NCR part no. 007-9814285).
2. Terminal wire, male (NCR part no. 007-2009663).
3. Cable, multiconductor (NCR part no. 006-5800006).
4. Connector (determined by remote device).
3 4
A
B
B006-6670-B000 21
Ethernet Standard Cable
The ethernet standard cable must be fully shielded, 8 pin, category 6 compliant for 6638 and category 5 for all other 663x ATMs. The cable must not exceed 97 m (318.2 ft) in length.
At the required point (see below) from the ATM end of the cable, remove the required amount of the outer sleeve, taking care not to cut through the cable shielding.
Dimension SelfServ 32 (front access)
SelfServ 34 & SelfServ 32 (rear access)
SelfServ 38
A 2.25 m (7.4 ft) 1.8 m (5.9 ft) not required
40 mm (1.6 in.)
22 B006-6670-B000
AC POWER AND DATA LINE TRANSIENT
PROTECTION
AC Power Line Transient Protection In the process of power distribution, transient electrical energy (including, but not limited to, lightning strikes, intermittent short circuits, and switching transients) can be introduced on to power lines. Such transient energy can be very damaging to electronic hardware and can also cause data corruption. Under these circumstances, NCR Corporation recommends the use of AC power transient suppressors and data (communication) line transient suppressors. Such protective devices are intended to guard against power and data line transients that can result in hardware damage and various system or program errors.
Improvement of any deficiencies in power quality is a customer responsibility.
Malfunction and/or component failure as a result of power quality problems are/is not covered by NCR Corporation Maintenance Agreement. NCR Corporation accepts no liability for any such occurrence nor for its consequences.
When power transient suppression is required, the suppressors used should meet the following minimum requirements:
● Dissipate energy to match the appropriate application categories as defined by ANSI/ IEEE Standard C62.41, Guide on Surge Voltages in Low-Voltage AC Power Circuits.
● Be of the voltage limiting (clipping), or tracking filter type. The suppressor must not ‘clamp’ the voltage to zero, and must self-recover after the passage of the transient.
The suppressor may be of the hybrid type construction that makes use of various technologies in order to meet speed and dissipation requirements.
● Exhibit a ‘short circuit’ mode upon its failure, thus providing a positive indication of its failure such as a blown fuse or tripped breaker
● Be listed by the accepted safety organization for the country involved (e.g. UL, CSA, VDE, ETL, etc.) and the installation must conform to local, state, and national electrical codes and regulations.
Location Category Comparable to IEC No 664 Category
Transient
Waveform Amplitudes
B = Major feeders, short branch circuits, and load centres
III Volts = 1.2 x 50 s Current = 8 x 20 s and
0.5 Rise - 100 kHz
Ringwave
6kV 3kA
6kV 500A
C = Service Entrance and run to load centre
IV Volts = 1.2 x 50 s Current = 8 x 20 s
10kV or more 10kA or more μ μ μ μ μ
B006-6670-B000 23
Data Line Transient Protection The nature of the transient phenomenon may extend to the data communication lines connected to this equipment. It is the responsibility of the customer to install and connect a data line transient suppression system to correct or prevent any deficiencies. Such systems must meet the following minimum requirements:
● Be of the self-recovering voltage limiting type. Exhibit a ‘short circuit’ mode upon its failure to ensure a positive indication of its failure. Insert minimum inductive and capacity loading at the operating frequency. Be installed in accordance with all applicable local, state, and national electrical codes and regulations.
● Protect the data port from damage in the presence of a data line transient event as defined in IEC Standard 1000-4-5 (formerly IEC 801-5).
Note: NCR provides a full line of both AC power and data line transient surge suppressors to protect your SelfServ ATM and reduce costly downtime and extend the life of the ATM Solution. For sizing and product information, please call NCR Site Preparation Services at the numbers shown at the end of this section.
Power Protection Products Other power problems can interrupt ATM transactions and potentially create a customer ATM downtime issue. For an ATM with a Cash Acceptor, the use of a UPS (Uninterruptible Power Supply) is strongly recommended to avoid downtime and the potential for the customer’s cash to be retained in the module during a power failure.
The following power protection products are available from NCR Site Preparation Services (see contact numbers at the end of this section):
● UPS (Uninterruptible Power Systems)
● Provides battery backup for power outages and brown-outs
● Includes AC and data line surge protection
● If needed, certain models provides basic voltage regulation
● Small size provides easy installation.
● Line Conditioners/Filters
● Incorporates an isolation transformer or filter that provides 100% isolation from disturbances on the incoming AC power line
● Removes EMI/RFI noise that cause equipment lockups
● Reduces common mode noise issues and surges / transients
● Significantly reduces POS downtime and component failure.
● Transient Voltage Surge Suppressors
● Provides protection from catastrophic AC surges/transients
● Provides data line protection from catastrophic surges that can migrate onto the data line and network.
24 B006-6670-B000
NCR Site Preparation Services Contact Information For more information from NCR’s Site Preparation Services group on the availability of power protection, data line transient suppressors and uninterruptible power supply products, warranty or configuration assistance, call the appropriate number below:
Region Telephone
USA and Canada +1 800 257 0458
Europe, Middle East and Africa +97 1501405904 or 919-228-2412 (US)
Caribbean and Latin America +55 21 2540 0058
Asia Pacific +91 93-80291285 B006-6670-B000 25
PLANNING CHECK LIST
To assist you in preparing your site for the arrival of your terminal we provide here a check list of the various procedures that you should carry-out prior to the arrival of your terminal. The procedures given are listed in chronological order, starting with the procedure that you should do first.
Activity
Select site and make scaled floor plan
Ensure correct environmental conditions
Establish all contractor and vendor related schedules
Check communication line requirements
Plan application development
Check floor plan and make any alterations
Install additional electrical outlets (if required)
Prepare site for data communication
Arrange for designing and printing of overlays/ decals
Order technical publications
Order media supplies
Plan operator training (optional)
Ensure data communications equipment is installed and tested
Ensure installation accessories are available 26 B006-6670-B000
To help NCR maintain the quality of their publications, send comments on the accuracy, clarity, usability, navigation, organization, and value of this book.
Address correspondence to:
Surface mail address:
NCR Financial Solutions Group Ltd
Information Solutions
Kingsway West
Dundee
Scotland
DD2 3XX
Email address:
userfeedback@exchange.scotland.ncr.com
| Front Cover |
| FCC Statement |
| Table of Contents |
| INTRODUCTION |
| ENVIRONMENTAL REQUIREMENTS |
| Temperature and Humidity |
| Normal Operating Range |
| Storage Range (Up To Three Months): |
| Transit Range (Up To One Week): |
| Extreme Power On Range (Up To One Hour): |
| Barometric Pressure |
| Electromagnetic Compatibility (EMC) and Safety |
| EMC Directives |
| Emission Standards |
| Additional Requirements for 220V - 240V Units |
| Immunity Standards |
| Safety Directive |
| Harmonised Safety Standard |
| Acoustics |
| Heat Dissipation |
| POWER REQUIREMENTS: SELFSERV 38 ONLY |
| AC Power Requirements |
| Input Voltage Setting |
| AC Wiring Details |
| Power Cable |
| AC Distribution Wiring Diagram |
| Grounding Requirements |
| Transient Power Loss |
| Third Party Surround/Topper Wiring |
| Customer Responsibilities |
| NCR Responsibilities |
| Recommended Wiring |
| When Wiring Cannot be Routed Externally |
| POWER REQUIREMENTS: SELFSERV 32 AND 34 |
| AC Power Requirements |
| Input Voltage Setting |
| Power Cable |
| Grounding Requirements |
| COMMUNICATIONS REQUIREMENTS |
| High Order Communications Standard Cable (RS-232) |
| Remote Device Cables |
| RS-232 Cable (9 pin) (not applicable to SelfServ 38 ATMs) |
| Remote Status Monitor |
| Alarm Interface Cable |
| Remote Relay Cable |
| Ethernet Standard Cable |
| AC POWER AND DATA LINE TRANSIENT PROTECTION |
| AC Power Line Transient Protection |
| Data Line Transient Protection |
| Power Protection Products |
| NCR Site Preparation Services Contact Information |
PLANNING CHECK LIST