SOW_Vertical CO2Tank 4172023.pdf
PDF 49 KB Posted
- Attached to
- Replacement Liquid Carbon Dioxide Tank Federal contract opportunity
- Solicitation number
- N0017423R0097
About this file
This statement of work outlines requirements for the purchase of a liquid carbon dioxide storage tank to support temperature conditioning testing at a Naval Surface Warfare Center facility. The vertical pressure vessel must be built to ASME section VIII Division I standards with a maximum allowable working pressure of 350 pounds per square inch gauge and a minimum design metal temperature of negative 40 degrees Fahrenheit. It must have a nominal liquid carbon dioxide capacity of 12,000 pounds and be insulated and covered with a weatherproof jacket. Additional requirements include an R404A refrigeration system with electrical controls for 460-volt power and associated gauges, valves, safety relief valves, and bleeder valve assemblies. Delivery is specified as building 1448 at an Indian Head, Maryland address or via an alternate delivery address. The point of contact provided is the technical lead for the Ballistics Test Branch at the Naval Surface Warfare Center Indian Head Division.
The related federal contract opportunity is solicitation number N0017423R0097 for the replacement of a liquid carbon dioxide tank to be awarded by the Department of the Navy Naval Sea Systems Command.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQ N0017423R0097.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
For the
Purchase of a Carbon Dioxide Storage Tank
4/12/2023
1.0 PURPOSE
Naval Surface Warfare Center Indian Head Division (NSWC IHD) Ballistics Test Branch
(R36) requires the purchase of a Liquid Carbon Dioxide storage tank to support temperature conditioning for vibration testing at building 1448. The temperature conditioning system requires liquid carbon dioxide to cool test units while they are being vibrated at cold temperatures. The current tank is leaking and needs to be replaced.
2.0 REQUIREMENTS PER SYSTEM
Vertical Pressure vessel built in accordance with ASME section VIII Division I
MAWP 350 PSIG, MDMT -40F
Nominal liquid carbon dioxide capacity is 12,000 pounds.
Vessel to be insulated and covered with a weather proof jacket.
R404A refrigeration system with electrical controls wired for 460-volt, 60 hertz, 3 phase.
6-inch face, 0-600 PSIG Pressure Gauge and 6-inch face differential pressure liquid levels indicator that reads in pounds and kilograms.
Stainless steel 1/4-turn isolation ball valves.
Dual ASME spring operated safety relief valve assembly set@ 350 PSIG with a 3-way selector valve.
Dual bleeder valve assembly set @ 330 PSIG with a ½ inch 3-way selector valve.
3.0 DELIVERY ADDRESS
Building 1448
5184 Strauss Avenue
Indian Head, MD 20640-5154
Via
Building 116
4081 N. Jackson Rd.
Indian Head, MD 20640-5116
4.0 TECHNICAL POINT OF CONTACT
Eric Meyer
Ballistics Test Branch (R36)
NSWC Indian Head
Indian Head, MD 20640
Phone: 301-744-4631
Email: eric.c.meyer.civ@us.navy.mil
File details come from the government source that posted it. Updated .