SOW PerkinElmer Quantulus (Final) - 8 May 24.pdf
PDF 494 KB Posted
- Solicitation number
- SS-AFRL-PZLEQ-2024-0019
About this file
This document is a Statement of Work (SOW) for the procurement of a PerkinElmer Quantulus GCT 6220 BGO Low Energy/Activity Liquid Scintillation Counter. The vendor shall provide a unit that runs on Windows 10, with salient characteristics including: E2/B sensitivity over 131,000 for tritium, BGO detector, sample capacity over 400 20mL samples, cooling mechanism, alpha/beta separation, sample replay capability, and connectivity for data export.
The related federal contract opportunity is a Sources Sought/Request for Information (SS/RFI) notice from the Air Force Research Laboratory (AFRL) for the same Quantulus GCT 6220 Low Activity Liquid Scintillation Counter. The notice is for market research purposes only, not a solicitation, and does not commit the government to an award. Interested small businesses are requested to provide company information, capability and experience, potential teammates, and any risks or unknowns. Responses should be submitted by the closing date to the identified points of contact.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work
Title: PerkinElmer Quantulus GCT 6220 BGO Low Energy/Activity Liquid Scintillation Counter
Document Date: 7 May 2024
Scope: The vendor shall provide a PerkinElmer Quantulus GCT 6220 BGO Low Energy/Activity Liquid Scintillation Counter. The unit shall run on an internal or external PC using Windows 10.
Background: This instrument is used for the ultra-low background analysis for tritium in bioassay samples.
Requirement/Salient Characteristics: The benchtop low activity liquid scintillation counter shall possess the following salient characteristics:
E2/B sensitivity is >131000 for Tritium in low level count mode, crucial to the detection of low activity tritium in bioassay samples
Utilize a BGO detector for low level sensitivity Include a computer that runs on Windows 10 Integrate with existing Tricarb Units for assay continuity across multiple machines Export data in custom comma delimited text for import into Laboratory Information
System, EDD report format must be editable to integrate to current LIMS Sample capacity of >400 20 mL samples at one time Equipped with cooling mechanism (internal) to lower temps on sample and detector to increase sensitivity and lower the ambient background counting capability Alpha and beta separation analysis Sample replay capability (reanalyze without recounting) Ethernet (LAN) and USB connectivity for data transfer Enhanced instrument performance assessment database to monitor efficiencies, backgrounds, E2/B and Chi-square values for H3, C14 over the life of instrument Contain Ba133 low energy external standard source and tSIE to eliminate the need to repeat counting the external standard to evaluate sample quench parameters Operate on 100-240 Vac 50/60 Hz (3 prong grounded plug) Industry standard manufacturer warranty
File details come from the government source that posted it. Updated .