SOW_OAK DS FY27_Doors Hatches Scuttle Fabrication_RHH 25R0.pdf

PDF 268 KB Posted

Attached to
CGC OAK WATER TIGHT DOORS, HATCHES, SCUTTLES RENEWAL
Solicitation number
70Z08526Q0027652
Issued by

About this file

This is a specification for the fabrication of watertight doors, hatches, and scuttles for the USCGC OAK (WLB 211) vessel during FY2027. The contractor is required to fabricate three items: one weathertight door (26" x 66" with a 14" x 18" window, lever-type knobs, and mortise locks) for the Pilot House; one watertight hatch (30" x 30" raised, quick-acting with 8 dogs and a 21" diameter cutout) for the Boson Storeroom; and one watertight scuttle (21" diameter raised, quick-acting) for the Escape Trunk. All work must comply with specified Coast Guard and NAVSEA drawings, including Drawing 225B WLB 167-001 (Structural Closures), Drawing FL1602-89 (Weathertight Door), and NAVSEA Drawing 167-7379842 (Welding Procedure for Watertight Doors).

The contractor must adhere to referenced standards including SFLC Standard Specifications 0000 (General Requirements), 0740 (Welding and Allied Processes), and 6310 (Ship Structure Preservation), as well as SSPC/NACE surface preparation standards and abrasive blasting specifications. All testing must be completed in accordance with SFLC Std Spec 0740. The contractor is responsible for constructing and providing shipping containers to deliver the completed doors and hatches to USCGC OAK at 47 Chandler Street, Newport, RI 02841, with shipping costs included in the bid. The period of performance spans from March 24, 2027, to February 6, 2027, at the vessel's homeport. No government-furnished property is provided. The specification document is Revision 0, dated August 13, 2027, developed by Chase E. Randall.

View the file

Other files

File Type Posted
Wage and Determinations Newport RI.pdf PDF
FAR CLAUSES FOR SERVICES.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USCGC OAK (WLB 211)

SPECIFICATION FOR FABRICATION OF WATERTIGHT DOORS, HATCHES, AND

SCUTTLES

FY2027

Developed By: Chase E. Randall

(Rev-0, 13 August 2027)

USCGC IDA LEWIS (WLM-551) DRYDOCK 175 MMA AVAILABILITY FY2025

ii (Rev-0)

TABLE OF CONTENTS

Revisions Record ......................................................................................................................................... iii Consolidated List of References WORK ITEM 1: Weathertight Door and Quick Acting Watertight Hatch, RenewError! Bookmark not defined.

USCGC OAK (WLB-211) DRYDOCK 225 MMA AVAILABILITY FY2025

iii (Rev-0)

Revisions Record This page is used to record specification revisions, which may have occurred subsequent to a Revision 0 (Rev-0) package. Information listed is intended to provide contractors and field unit personnel a means to ensure all the current specification revision pages are present when reviewing or utilizing this specification package.

DATE REV# WORK

ITEM#

CHANGES MADE

NOTE : All work item and paragraph numbers listed above for a given revision correspond to same numbers in the previous revision. This revised specification is self-contained with all of the above listed changes incorporated.

Consolidated List of References The below-listed documents form a part of this specification to the extent specified herein.

Approval/publication dates or revision dates/numbers are also identified, to ensure that same document versions are used at the time of specification writing and during contract execution.

All Coast guard drawings, technical publications, and standard specifications will be provided to contractors by the Coast Guard at an appropriate time, or upon request, free of charge. Other Government documents may be accessed – free of charge – from links located on the SFLC website. Commercial sites provide access to their respective documents.

COAST GUARD DRAWINGS

Coast Guard Drawing 225B WLB 167-001, Rev-R, Structural Closures Coast Guard Drawing 225B-WLB-631-001, Rev G, 2000, Paint Schedule NAVSEA Drawing 167-7379842, Rev A, Procedure & Welding Sequence for Non-Ballistic, Watertight & Airtight Quick Acting or Individually Dogged Personnel Doors

COAST GUARD PUBLICATIONS

Coast Guard Commandant Instruction (COMDTINST) M10360.3, Jun 2006, Coatings and Colors

Manual Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures

OTHER REFERENCES

Code of Federal Regulations (CFR) Title 29, Part 1915, Occupational Safety and Health

Standards for Shipyard Employment Commercial Item Description (CID) A-A-59316, 2016, Abrasive Materials; for Blasting Military Specification MIL-A-22262B, March 1996, Abrasive Blasting Media Ship Hull Blast

Cleaning NAVSEA Technical Publication T9074-AD-GIB-010/1688, (TP 1688), July 2012, Requirements for Fabrication, Welding, and Inspection of Submarine Structure The Society for Protective Coatings (SSPC) Surface Preparation Standard No. 11 (SSPC-SP 11), 2013, Power-Tool Cleaning to Bare Metal The Society for Protective Coatings (SSPC)/NACE International (NACE) 2007, Joint Surface

Preparation Standard SSPC-SP 10/NACE No. 2, Near-White Metal Blast Cleaning

WORK ITEM 1: Fabrication of Watertight and Non-Watertight Doors, Hatches, and Scuttles

1. SCOPE

1.1 Intent. This work item describes the requirements for the Contractor to fabricate watertight and non-water tight doors, hatches, and scuttles identified in Table 1 in accordance with drawings and references.

TABLE 1 - WATERTIGHT DOORS AND SCUTTLE LOCATIONS

Description Location P/N and Description QTY Drawing

Weathertight Door

Pilot House (03-56-0-C)

PN 21

DOOR- 26” X 66” C.O.,

EAT, LH W/ 14” X 18”

C.O. WINDOW W/

LEVER TYPE KNOBS

AND MORTISE LOCKS

01 Each

225B WLB 167-

USCG DWG FL-

1602-89

Watertight Hatch

Boson Strm #1 (1-0-0-A)

PN 17

HATCH- 30” X 30”

C.O., RSD, WTRTT, 8

DOG, WITH A 21”

DIA. C.O., QA

NAVSEA 805-

1624093 SIMILAR

TO NAVSEA

DWG 803-1401892

HATCH

COAMING 12”

HEIGHT

Watertight Scuttle

Escape Trunk (1-19-2-T)

PN 6

SCUTTLE- 21” DIA

C.O., RSD, QA,

WTRTT

SIMILAR TO

NAVSEA DWG

803-1401892

SCUTTLE

COAMING 12”

HEIGHT

1.2 Government-furnished property

None

2. REFERENCES

COAST GUARD DRAWINGS

Coast Guard Drawing 225B-WLB-167-001, Rev W, Structural Closures Coast Guard Drawing 225B-WLB-601-001, Rev P, General Arrangements, Inboard and Outboard

Profiles Coast Guard Drawing USCG DWG FL-1602-89, Rev -, Fleet, 26” x 66” Weathertight Door NAVSEA Drawing 167-7379842, Rev A, Procedure & Welding Sequence for Non-Ballistic, Watertight & Airtight Quick Acting or Individually Dogged Personnel Doors

COAST GUARD PUBLICATIONS

Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures

OTHER REFERENCES

Commercial Item Description (CID) A-A-59316, 2016, Abrasive Materials; for Blasting Military Specification MIL-A-22262B, March 1996, Abrasive Blasting Media Ship Hull Blast

Cleaning The Society for Protective Coatings (SSPC)/NACE International (NACE) 2007, Joint Surface

Preparation Standard SSPC-SP 10/NACE No. 2, Near-White Metal Blast Cleaning The Society for Protective Coatings (SSPC) Surface Preparation Standard No. 11 (SSPC-SP 11), 2013, Power-Tool Cleaning to Bare Metal NAVSEA Drawing 803-1401892, Rev J, Scuttle, WT, Raised, Quick Acting, 21” Dia NAVSEA Drawing 805-1624092, Rev E, Hatch, WT, Raised, Quick Acting, 30”x30” with

Scuttle NAVSEA Drawing 805-1624093, Quick Acting Watertight Scuttle

3. REQUIREMENTS

3.1 General.

3.1.1 CIR.

None.

3.1.2 Tech Rep.

Not applicable.

3.1.3 Protective measures. Not Applicable

3.1.4 Interferences. Not Applicable

3.1.5 Testing. All testing to be completed in accordance with drawings and Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes

3.1.6 Shipping. Contractor shall construct container to ship doors and hatches and must include pricing for shipping to USCGC OAK, C/O CWO Jason Martin, 47 Chandler Street Newport, RI 02841, USA.

4. NOTES

Period of Performance: 03/24/027 to 02/06/027 at homeport.

Revisions Record
Consolidated List of References
WORK ITEM 1: Fabrication of Watertight and Non-Watertight Doors, Hatches, and Scuttles

File details come from the government source that posted it. Updated .