SOW HTK EQUIPMENT.docx

DOCX document 18 KB Posted

Attached to
7320--Healthy Teaching Kitchen Equipment Federal contract opportunity
Solicitation number
36C25923Q0578
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19

View the file

Other files for this federal contract opportunity

Other files attached to 7320--Healthy Teaching Kitchen Equipment, newest first.
File Type Posted
36C25923Q0578 0003.docx DOCX document
Healthy Kitchen Sink Dimensions 05042023 with Legend.pdf PDF
36C25923Q0578 0002.docx DOCX document
Healthy Kitchen Sink Dimensions 05042023.pdf PDF
36C25923Q0578 0001.docx DOCX document
36C25923Q0578.docx DOCX document
852.219-76 VA Notice of Limitations on Subcontracting_Certificate of Compliance for Supplies and Products.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK (SOW)

Oklahoma City VA Medical Center 921 NE 13th Street Oklahoma City, OK. 73104

Salient Characteristics Required:

0001-Counter, Stainless w/sink MPN Custom 20"x14"x10" deep sink QTY.1 J‐SHAPED COUNTER WITH SINKS ‐ 14-gauge stainless steel top with an 8" backsplash at walls. Top to include (1) 20"x 14" x 10" deep sink with lever drain, overflow, and faucet. Provide (1) 10" x 14" x 8" deep sink with basket drain, faucet, and splash guards as required. Top to include (2) stainless steel trash rings with Rubbermaid trash cans below. Provide a 20" x 20" x 3/4" thick poly cutting board recessed in top. Counter to be unibody constructed of 18-gauge stainless steel walls and locking hinged doors. Interior to include 16-gauge stainless steel shelving. Unit to be mounted on 6" adjustable legs with removable stainless steel toe kick. Soap/Towel Dispensers, Buyout Equipment, and Electrical to be provided by others.

0002-Counter, Stainless w/sink MPN Custom emp #2 irregular shape counter sink QTY.1 IRREGULAR SHAPED COUNTER WITH SINK-stainless steel top with an 8" backsplash at walls. Top to include (1) 20" x 14" x 10" deep sink with lever drain, overflow, and faucet. Top to include (1) stainless steel trash ring with Rubbermaid trash can below. Counter to be unibody constructed of 18 gauge stainless steel walls and locking hinged doors. Interior to include 16-gauge stainless steel shelving. Unit to be mounted on 6" adjustable legs with removable stainless steel toe kick. Soap/Towel Dispensers, Buyout Equipment, and Electrical to be provided by others.

0003-Counter, stainless Fabricated MPN Custom L shaped counter QTY.1 L‐SHAPED COUNTER ‐stainless steel top with an 8" backsplash at end. Counter to be unibody constructed of 18-gauge stainless steel walls, locking hinged doors, and ADA recess. Interior to include 16-gauge stainless steel shelving. Unit to be mounted on 6" adjustable legs with removable stainless steel toe kick. Buyout Equipment and Electrical to be provided by others.

0004-Microwave Oven Brand name or equal to Model No. Menumaster MFS12TS QTY.3 Commercial Microwave Oven, countertop, 1200 watts, 1.2 cu. ft. capacity, stackable, medium volume, (2) magnetrons, 4‐ stage cooking, (5) power levels, (100) memory settings, Braille touch pads, removable air filter, stainless steel interior/exterior with sealed‐in ceramic shelf, side hinged door, removable air filter, 120v/60/1‐ph, 1800 total watts, 15 amps, cord, NEMA 5‐20P, ETL, cETLus , 3-year full warranty, standard

0005-RANGE, VENTLESS, ELECTRIC

Brand name or equal to Wells Model No. WVO‐4HF QTY.3 Ventless Cooktop, electric, (4) French plates, thermostatic controls, self‐contained hood system, stainless steel construction, convection oven base, front legs, rear casters, cUL . 208v/60/3‐ph, 11.5 kW, NEMA 15‐60P. 22618 Pre‐Filter, fits VCS systems, WVU‐48, WVU‐72, & WVU‐96. 22619 HEPA Charcoal Filter Pack, for VCS systems.

0006-TABLE, WORK, 14 GAUGE, BACK SPLASH QTY.1

FABRICATED COUNTER ‐ stainless steel top with an 8" backsplash at rear. Counter to be unibody constructed of 18-gauge stainless steel walls and 16-gauge stainless steel shelving. Unit to be mounted on 6" adjustable legs with removable stainless steel toe kick. Buyout Equipment and Electrical to be provided by others.

0007-STORAGE CABINET QTY.1

Brand name or equal to Advance Tabco Model No. CAB‐4 Free Standing Cabinet, 25‐3/16"W x 22‐3/4"D x 84"H, (1) left‐hinged door, (4) 12"D fixed intermediate shelves, slotted side panels for ventilation, 18/430 series stainless steel, all welded construction, NSF. SU‐27 Door lock, for underbar and mop sink cabinets, with key (one required for each door, double mop sink cabinets and underbar cabinets over 24" left to right have (2) doors).

0008-REACH‐IN REFRIGERATOR QTY.1

Brand name or equal to Traulsen Model No. RHT132NUT‐HHS Spec‐Line Refrigerator, Reach‐in, one‐section, 21.9 cu. ft., self‐ contained refrigeration, stainless steel exterior and interior, standard depth, narrow half‐height doors, (3) adjustable wire shelves per section, microprocessor controls, 6" adjustable stainless steel legs, 1/3 HP, cULus, UL‐Sanitation, ENERGY STAR. 115v/60/1‐ph, 6.7 amps, with cord & NEMA 5‐15P, standard. 3 year service/labor, 5 year compressor warranty, standard. Door hinged on left, Casters, 6" high (set of 4).

0009-HAND SINK QTY.1

Brand name or equal to Advance Tabco Model No. 7‐PS‐90 Hand Sink, pedestal mounted base, 14" wide x 10" front‐to‐back x 5" deep bowl, 20 gauge 304 stainless steel, splash mounted faucet, pedal valves with easy access design, basket drain, wall bracket, NSF, cCSAus. 7‐PS‐17 Welded Side Splash, 7‐3/4"H (installed height), both sides, for hand sinks with 14" wide x 10" front‐to‐back bowl, splash mounted faucets.

0010-INSTALLATION

Labor and materials required to install a Healthy Teaching Kitchen at the Oklahoma City VA Health Care System to include:

1) Receive and store all equipment for up to 30 days.

2) Deliver the equipment to the VAMC OKC, uncrate, move the equipment into the room, assemble and weld the counters as needed.

3) Make final connections of all equipment to electric, water and drains.

4) Remove debris, confirm operation of all equipment, clean and make ready for final use.

DELIVERY

Delivery is required to Oklahoma City VA Medical Center located at:

921 NE 13th Street Oklahoma City, OK. 73104

File details come from the government source that posted it. Updated .