SOW - Functional Performance Specs.docx

DOCX document 25 KB Posted

Attached to
7B22--Lenel System Server Replacement - IC Federal contract opportunity
Solicitation number
36C26324Q0825
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23

About this file

This document is a Statement of Work (SOW) for a Dell PowerEdge R450 server to replace an existing Lenel Security System (LSS) server that has reached end of life. The SOW specifies the required server configuration and performance characteristics, as well as the labor and services needed to remove the existing server, back up data, install the new server, restore the database, and update the Lenel software.

The related federal contract opportunity is a Notice of Intent for a sole source firm fixed price contract with Communications Engineering Company to provide the Lenel server replacement in support of the Iowa City VA Health Care System. The justification for the sole source award cites Communications Engineering Company as the original equipment manufacturer authorized servicer for the existing Lenel system, and the only entity able to provide maintenance and support without voiding warranties or proprietary rights.

View the file

Other files for this federal contract opportunity

Other files attached to 7B22--Lenel System Server Replacement - IC, newest first.
File Type Posted
36C26324Q0825.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Functional/Performance/Specification General Equipment Name: Dell PowerEdge R450 Server for Lenel Security System Description & Salient Characteristics The server for the Lenel Security System (LSS) needs to be replaced. The LSS hosts all PIV interactions with card readers, control access levels, panic alarm server. Server has reached the end of it's supported lifecycle. Future updates are not possible nor supported by Windows. Risk server failure and loss of PIV, access control, functions throughout the facility and CBOCs.

Required Individual Line Items & Quantity of Items

· Dell PowerEdge R450 server

· (1 ea.) 1U Rackmount

· (1 ea.) Intel Xeon Silver 4309Y

· (1 ea.) 32 GB (4) 8 GB Memory

· (1 ea.) Boss Controller Card w/2 M.2 Sticks 240G (RAID 1)

· (3 ea.) 600 GB 15K RPM SAS 12GBPS 512N 2.5” Hot-Plug Hard Drive

· (1 ea.) External 8X DVD-ROM USB

· (1 ea.) Dual Hot-Plug Power Supply Redundant (1+1) 800W Mixed Mode, NAF, Windows Server 2022 Standard 16 Core, FI, No Med, No Cal, Multi Language

· (1 ea.) A11 Drop-In/Stab-In Combo Rails W/O Cable Management Arm

· (2 ea.) Power Cords (C13)

· Labor and equipment to remove and replace an on premise Lenel access control database server

· Backup existing server

· Install new rack mounted server

· Restore existing database

· Perform functional test of all database and communications services to ensure operational success

· Upon successful migration to new server perform Lenel version update to 8.0

· Depending on the Genasys software compatibility at the time of execution Lenel version can be upgraded to 8.1