SOW Draft Thermojet DPG 14Aug24.docx
DOCX document 28 KB Posted
- Attached to
- DPG ThermoJets and Recirculating Coolers
- Solicitation number
- W911S6-24-Thermojet
About this file
This document is a Scope of Work (SOW) draft for the purchase of ATS ThermoJets and Recirculating Coolers for the U.S. Army Dugway Proving Ground's West Desert Test Center, Chemical Test Division. The SOW outlines the requirements for 6 ThermoJet ES systems with detailed specifications for temperature range, accuracy, airflow, and other features, as well as 6 Recirculating Coolers with specifications for temperature range, heat removal capacity, pump, and other details.
The related federal contract opportunity is a sources sought notice for a competitive procurement of the ThermoJets and Recirculating Coolers to support the Dugway Proving Ground's test chambers and fixtures. The Mission Installation Contracting Command (MICC) at Fort Hood is the procuring agency, and they are seeking responses from both large and small businesses, including 8(a), small disadvantaged, HUBZone, Service-Disabled Veteran-Owned, and Women-Owned Small Businesses, to potentially set aside the procurement. The ThermoJets and Recirculating Coolers are critical, common components that have been verified and validated for the test chambers.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sources Sought ThermoJet DPG 14Aug24.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Scope of Work for ATS Scientific Products ThermoJets and Recirculating Coolers
DRD # 3665
14 August 2024
United States ARMY DUGWAY PROVING GROUND
WEST DESERT TEST CENTER, CHEMICAL TEST DIVISION
DUGWAY, UTAH 84022-5000
1. Subject: Purchase ATS ThermoJets and Recirculating Coolers
2. Final Delivery Location: West Desert Test Center, U.S. Army Dugway Proving Ground, Utah.
3. Background:
a. This Scope of Work outlines the requirements for purchasing the ATS ThermoJets and recirculating coolers.
b. Currently WDTC, Chemical Test Divisions (CTD) uses the ThermoJets and Recirculating coolers to provide environmental conditions for several of our major test chambers/fixtures. These systems provide a wide range of high/low controlled temperatures critical to our test programs requirements.
c. The ThermoJets and Recirculating systems have been verified and validated (V&V) as the primary heating and cooling systems for test fixtures such as the SWATCH (SPITFIRE), and the Small Item Decon (SID) Chamber. These units will be the primary environmental controls systems for the newly designed SMARTMAN Boot & Glove and AVLAG Seams & Closure test chambers/fixtures.
d. The CTD established a process to keep common equipment items standard across the test chambers and fixtures. The ThermoJets and Recirculating cooling systems are two components that are common to all test systems and have been V&V by the testing community.
4. Scope of Work Requirements:
a. Request that Vendor provide the following items.
(1) 6 each, Part Number: THJ80ES10000, Description: ThermoJet ES: Environment Simulator & Precision Temperature Cycling System
a. Temperature
i. Temperature range: -80C to +225C
ii. Accuracy: +/-1C
iii. Set ability: 0.1C
iv. Indication: 0.1C
v. Stability: +/-0.5C at DUT
vi. Ramp Rate: 1C to 999C Min or Max
b. Dual stage mechanical refrigeration, no LN2 or CO2 required
c. No-Arm and no air delivery line; chamber ready
d. Built-in electrically grounded work surface
e. Air Filters
i. Water, Oil, & Particle
f. Air Dryers
i. Heatless regenerative: -85C dew point
g. Airflow (output)
i. Range: 5 - 20 SCFM
ii. Set ability: 1 SCFM
h. System Controller
i. Type Microprocessor PLC-based PID
ii. Remote-able, touch-Screen control with auto-tuning, datalogging, and multi-level password protection
iii. Program: 48 programs of 8 segments each
iv. Safeties: Low flow, over temp, EMO interlock
v. Status indication: Air input, air temp, air/DUT control OK, run/idle, purge, defrost, power Thermocouples: Type T Internal/external for temperature control/monitoring
vi. Available limits: Ramp rate, Min/Max air temperature
vii. GPIB and RS232 Interface
i. Physical Characteristics
i. Footprint: 21" wide x 27" deep
ii. Arm reach: 55" radius
iii. Work surface height: 38"
iv. Weight: 425 lbs.
v. Mobility: 4 full swivels, easily lockable casters
vi. Front mounted handle for easy mobility
(2) 6 each, Part Number: CH6, Description: Flexible Hose To be used with the ThermoJet
a. Length: 76"
b. Temperature Range: -80C to +125C
c. Connection: Swagelock 1/2" male.
(3) 6 each, Part Number: RC211C0, Description: ULT RECIRCULATING COOLER
a. Temp Range: -80 C to +75C
b. Heat Removal: 880W @ -60C, 1150W @ -40C
c. Pump: 2 to 3 GPM @ 22 PSI; dependent on temp and fluid
d. Reservoir: 5 Liter
e. Control: Deluxe Digital, PID
i. RS-232 interface
ii. 0.1 indication
iii. Low fluid alarm
iv. Low flow alarm
v. Overtemperature alarm with contact closure
vi. Remote RTD sensor
f. Heater: 1126W (1500 W nominal 240V)
g. Connections: 1/2" NPT, Male
h. Dimensions: 21"W x 29"D x 48"H
i. Weight: 400 lbs
j. Electrical: 208V/60Hz/1PH
k. Condenser: Air Cooled.